215 results on '"Clouse ME"'
Search Results
2. Hepatic utilization of exogenous nucleotide precursors for restoration of ATP after cold ischemia in rats
- Author
-
Palombo, JD, primary, Bowers, JL, additional, Clouse, ME, additional, McCullough, A, additional, Forse, RA, additional, and Bistrian, BR, additional
- Published
- 1993
- Full Text
- View/download PDF
3. Coronary CT angiography using 64 detector rows: methods and design of the multi-centre trial CORE-64.
- Author
-
Miller JM, Dewey M, Vavere AL, Rochitte CE, Niinuma H, Arbab-Zadeh A, Paul N, Hoe J, de Roos A, Yoshioka K, Lemos PA, Bush DE, Lardo AC, Texter J, Brinker J, Cox C, Clouse ME, Lima JA, Miller, Julie M, and Dewey, Marc
- Abstract
Multislice computed tomography (MSCT) for the noninvasive detection of coronary artery stenoses is a promising candidate for widespread clinical application because of its non-invasive nature and high sensitivity and negative predictive value as found in several previous studies using 16 to 64 simultaneous detector rows. A multi-centre study of CT coronary angiography using 16 simultaneous detector rows has shown that 16-slice CT is limited by a high number of nondiagnostic cases and a high false-positive rate. A recent meta-analysis indicated a significant interaction between the size of the study sample and the diagnostic odds ratios suggestive of small study bias, highlighting the importance of evaluating MSCT using 64 simultaneous detector rows in a multi-centre approach with a larger sample size. In this manuscript we detail the objectives and methods of the prospective "CORE-64" trial ("Coronary Evaluation Using Multidetector Spiral Computed Tomography Angiography using 64 Detectors"). This multi-centre trial was unique in that it assessed the diagnostic performance of 64-slice CT coronary angiography in nine centres worldwide in comparison to conventional coronary angiography. In conclusion, the multi-centre, multi-institutional and multi-continental trial CORE-64 has great potential to ultimately assess the per-patient diagnostic performance of coronary CT angiography using 64 simultaneous detector rows. [ABSTRACT FROM AUTHOR]
- Published
- 2009
- Full Text
- View/download PDF
4. Characterization of coronary atherosclerosis by dual-source computed tomography and HU-based color mapping: a pilot study.
- Author
-
Brodoefel H, Reimann A, Heuschmid M, Tsiflikas I, Kopp AF, Schroeder S, Claussen CD, Clouse ME, Burgstahler C, Brodoefel, H, Reimann, A, Heuschmid, M, Tsiflikas, I, Kopp, A F, Schroeder, S, Claussen, C D, Clouse, M E, and Burgstahler, C
- Abstract
To assess HU-based color mapping for characterization of coronary plaque, using intravascular ultrasound virtual histology (IVUS-VH) as a standard of reference. Dual-source computed tomography and IVUS-VH were prospectively performed in 13 patients. In five lesions, HU thresholds of the color-coding software were calibrated to IVUS-VH. In a 15-lesion verification cohort, volumes of vessel, lumen and plaque or percentages of lipid, fibrous and calcified components were obtained through use of pre-set HU cut-offs as well as through purely visual adjustment of color maps. Calibrated HU ranges for fatty or fibrous plaque, lumen and calcification were -10-69, 70-158, 159-436 and 437+. Using these cut-offs, HU-based analysis achieved good agreement of plaque volume with IVUS (47.0 vs. 51.0 mm(3)). Visual segmentation led to significant overestimation of atheroma (61.6 vs. 51.0 mm(3); P = 0.04) Correlation coefficients for volumes of vessel, lumen and plaque were 0.92, 0.87 and 0.83 with HU-based analysis or 0.92, 0.85 and 0.71 with visual evaluation. With both methods, correlation of percentage plaque composition was poor or insignificant. HU-based plaque analysis showed good reproducibility with intra-class correlation coefficients being 0.90 for plaque volume and 0.81, 0.94 or 0.98 for percentages of fatty, fibrous or calcified components. With use of optimized HU thresholds, color mapping allows for accurate and reproducible quantification of coronary plaque. [ABSTRACT FROM AUTHOR]
- Published
- 2008
- Full Text
- View/download PDF
5. How useful is computed tomography for screening for coronary artery disease? Noninvasive screening for coronary artery disease with computed tomography is useful.
- Author
-
Clouse ME
- Published
- 2006
6. Hepatic hemangioma: atypical appearance
- Author
-
Mikulis, DJ, primary, Costello, P, additional, and Clouse, ME, additional
- Published
- 1985
- Full Text
- View/download PDF
7. CT body stereotaxis: an aid for CT-guided biopsies
- Author
-
Onik, G, primary, Costello, P, additional, Cosman, E, additional, Wells, T, additional, Goldberg, H, additional, Moss, A, additional, Kane, R, additional, Clouse, ME, additional, Hoddick, W, additional, Moore, S, additional, and et, al., additional
- Published
- 1986
- Full Text
- View/download PDF
8. Noninvasive testing for carotid artery stenosis: II. Clinical application of accuracy assessments
- Author
-
O'Leary, DH, primary, Clouse, ME, additional, Persson, AV, additional, and Edwards, SA, additional
- Published
- 1982
- Full Text
- View/download PDF
9. Noninvasive testing for carotid artery stenosis: I. Prospective analysis of three methods
- Author
-
O'Leary, DH, primary, Persson, AV, additional, and Clouse, ME, additional
- Published
- 1981
- Full Text
- View/download PDF
10. Dormia basket modification for percutaneous transhepatic common bile duct stone removal
- Author
-
Clouse, ME, primary
- Published
- 1983
- Full Text
- View/download PDF
11. Complications of long term transbrachial hepatic arterial infusion chemotherapy
- Author
-
Clouse, ME, primary, Ahmed, R, additional, Ryan, RB, additional, Oberfield, RA, additional, and McCaffrey, JA, additional
- Published
- 1977
- Full Text
- View/download PDF
12. Mechanical effect of balloon angioplasty: case report with histology
- Author
-
Clouse, ME, primary, Tomashefski, JF, additional, Reinhold, RE, additional, and Costello, P, additional
- Published
- 1981
- Full Text
- View/download PDF
13. MRI of the Budd-Chiari syndrome
- Author
-
Stark, DD, primary, Hahn, PF, additional, Trey, C, additional, Clouse, ME, additional, and Ferrucci, JT, additional
- Published
- 1986
- Full Text
- View/download PDF
14. Subselective angiography in localizing insulinomas of the pancreas
- Author
-
Clouse, ME, primary, Costello, P, additional, Legg, MA, additional, Soeldner, SJ, additional, and Cady, B, additional
- Published
- 1977
- Full Text
- View/download PDF
15. Gastroduodenal ulceration after hepatic arterial infusion chemotherapy
- Author
-
Hall, DA, primary, Clouse, ME, additional, and Gramm, HF, additional
- Published
- 1981
- Full Text
- View/download PDF
16. Complications of lymphangiography in patients of advanced age
- Author
-
Sokol, GH, primary, Clouse, ME, additional, Kotner, LM, additional, and Sewell, JB, additional
- Published
- 1977
- Full Text
- View/download PDF
17. Hypoglycemia and extrapancreatic tumors: a report of two cases
- Author
-
Costello, P, primary, Clouse, ME, additional, and Rolla, AR, additional
- Published
- 1979
- Full Text
- View/download PDF
18. Diagnostic accuracy of computed tomography coronary angiography according to pre-test probability of coronary artery disease and severity of coronary arterial calcification. The CORE-64 (Coronary Artery Evaluation Using 64-Row Multidetector Computed Tomography Angiography) International Multicenter Study.
- Author
-
Arbab-Zadeh A, Miller JM, Rochitte CE, Dewey M, Niinuma H, Gottlieb I, Paul N, Clouse ME, Shapiro EP, Hoe J, Lardo AC, Bush DE, de Roos A, Cox C, Brinker J, Lima JA, Arbab-Zadeh, Armin, Miller, Julie M, Rochitte, Carlos E, and Dewey, Marc
- Abstract
Objectives: The purpose of this study was to assess the impact of patient population characteristics on accuracy by computed tomography angiography (CTA) to detect obstructive coronary artery disease (CAD).Background: The ability of CTA to exclude obstructive CAD in patients of different pre-test probabilities and in presence of coronary calcification remains uncertain.Methods: For the CORE-64 (Coronary Artery Evaluation Using 64-Row Multidetector Computed Tomography Angiography) study, 371 patients underwent CTA and cardiac catheterization for the detection of obstructive CAD, defined as ≥50% luminal stenosis by quantitative coronary angiography (QCA). This analysis includes 80 initially excluded patients with a calcium score ≥600. Area under the receiver-operating characteristic curve (AUC) was used to evaluate CTA diagnostic accuracy compared to QCA in patients according to calcium score and pre-test probability of CAD.Results: Analysis of patient-based quantitative CTA accuracy revealed an AUC of 0.93 (95% confidence interval [CI]: 0.90 to 0.95). The AUC remained 0.93 (95% CI: 0.90 to 0.96) after excluding patients with known CAD but decreased to 0.81 (95% CI: 0.71 to 0.89) in patients with calcium score ≥600 (p = 0.077). While AUCs were similar (0.93, 0.92, and 0.93, respectively) for patients with intermediate, high pre-test probability for CAD, and known CAD, negative predictive values were different: 0.90, 0.83, and 0.50, respectively. Negative predictive values decreased from 0.93 to 0.75 for patients with calcium score <100 or ≥100, respectively (p = 0.053).Conclusions: Both pre-test probability for CAD and coronary calcium scoring should be considered before using CTA for excluding obstructive CAD. For that purpose, CTA is less effective in patients with calcium score ≥600 and in patients with a high pre-test probability for obstructive CAD. [ABSTRACT FROM AUTHOR]- Published
- 2012
- Full Text
- View/download PDF
19. Predicting Significant Coronary Obstruction in a Population with Suspected Coronary Disease and Absence of Coronary Calcium: CORE-64 / CORE320 Studies.
- Author
-
Armstrong AC, Cerci R, Matheson MB, Magalhães T, Kishi S, Brinker J, Clouse ME, Rochitte CE, Cox C, Lima JAC, and Arbab-Zadeh A
- Subjects
- Humans, Female, Calcium, Coronary Angiography methods, Predictive Value of Tests, Heart, Risk Factors, Coronary Vessels diagnostic imaging, Risk Assessment, Coronary Artery Disease diagnostic imaging, Coronary Artery Disease epidemiology, Coronary Occlusion, Vascular Calcification diagnostic imaging
- Abstract
Background: Coronary artery calcium (CAC) scanning can be performed using non-contrast computed tomography to predict cardiovascular events, but has less value for risk stratification in symptomatic patients., Objective: To identify and validate predictors of significant coronary obstruction (SCO) in symptomatic patients without coronary artery calcification., Methods: A total of 4,258 participants were screened from the CORE64 and CORE320 studies that enrolled patients referred for invasive angiography, and from the Quanta Registry that included patients referred for coronary computed tomography angiography (CTA). Logistic regression models evaluated associations between cardiovascular risk factors, CAC, and SCO. An algorithm to assess the risk of SCO was proposed for patients without CAC. Significance level of 5% was used in the analyses., Results: Of the 509 participants of the CORE study, 117 (23%) had zero coronary calcium score; 13 (11%) patients without CAC had SCO. Zero calcium score was related to younger age, female gender, lower body mass index, no diabetes, and no dyslipidemia. Being a current smoker increased ~3.5 fold the probability of SCO and other CV risk factors were not significantly associated. Considering the clinical findings, an algorithm to further stratify zero calcium score patients was proposed and had a limited performance in the validation cohort (AUC 58; 95%CI 43, 72)., Conclusion: A lower cardiovascular risk profile is associated with zero calcium score in a setting of high-risk patients. Smoking is the strongest predictor of SCO in patients without CAC.
- Published
- 2023
- Full Text
- View/download PDF
20. Prognostic value of noninvasive combined anatomic/functional assessment by cardiac CT in patients with suspected coronary artery disease - Comparison with invasive coronary angiography and nuclear myocardial perfusion imaging for the five-year-follow up of the CORE320 multicenter study.
- Author
-
Dewey M, Rochitte CE, Ostovaneh MR, Chen MY, George RT, Niinuma H, Kitagawa K, Laham R, Kofoed K, Nomura C, Sakuma H, Yoshioka K, Mehra VC, Jinzaki M, Kuribayashi S, Laule M, Paul N, Scholte AJ, Cerci R, Hoe J, Tan SY, Rybicki FJ, Matheson MB, Vavere AL, Arai AE, Miller JM, Cox C, Brinker J, Clouse ME, Di Carli M, Lima JAC, and Arbab-Zadeh A
- Subjects
- Computed Tomography Angiography, Coronary Angiography, Follow-Up Studies, Humans, Predictive Value of Tests, Prognosis, Prospective Studies, Tomography, X-Ray Computed, Coronary Artery Disease diagnostic imaging, Myocardial Perfusion Imaging
- Abstract
Background: Few data exist on long-term outcome in patients undergoing combined coronary CT angiography (CTA) and myocardial CT perfusion imaging (CTP) as well as invasive coronary angiography (ICA) and single photon emission tomography (SPECT)., Methods: At 16 centers, 381 patients were followed for major adverse cardiac events (MACE) for the CORE320 study. All patients underwent coronary CTA, CTP, and SPECT before ICA within 60 days. Prognostic performance according binary results (normal/abnormal) was assessed by 5-year major cardiovascular events (MACE) free survival and area under the receiver-operating-characteristic curve (AUC)., Results: Follow up beyond 2-years was available in 323 patients. MACE-free survival rate was greater among patients with normal combined CTA-CTP findings compared to ICA-SPECT: 85 vs. 80% (95% confidence interval [CI] for difference 0.1, 11.3) though event-free survival time was similar (4.54 vs. 4.37 years, 95% CI for difference: -0.03, 0.36). Abnormal results by combined CTA-CTP was associated with 3.83 years event-free survival vs. 3.66 years after abnormal combined ICA-SPECT (95% CI for difference: -0.05, 0.39). Predicting MACE by AUC also was similar: 65 vs. 65 (difference 0.1; 95% CI -4.6, 4.9). When MACE was restricted to cardiovascular death, myocardial infarction, or stroke, AUC for CTA-CTP was 71 vs. 60 by ICA-SPECT (difference 11.2; 95% CI -1.0, 19.7)., Conclusions: Combined CTA-CTP evaluation yields at least equal 5-year prognostic information as combined ICA-SPECT assessment in patients presenting with suspected coronary artery disease. Noninvasive cardiac CT assessment may eliminate the need for diagnostic cardiac catheterization in many patients., Clinical Trial Registration: NCT00934037., (Copyright © 2021 Society of Cardiovascular Computed Tomography. All rights reserved.)
- Published
- 2021
- Full Text
- View/download PDF
21. Comparative effectiveness of coronary artery stenosis and atherosclerotic plaque burden assessment for predicting 30-day revascularization and 2-year major adverse cardiac events.
- Author
-
Kishi S, Magalhães TA, Cerci RJ, Zimmermann E, Matheson MB, Vavere A, Tanami Y, Kitslaar PH, George RT, Brinker J, Miller JM, Clouse ME, Lemos PA, Niinuma H, Reiber JHC, Kofoed KF, Rochitte CE, Rybicki FJ, Di Carli MF, Cox C, Lima JAC, and Arbab-Zadeh A
- Subjects
- Aged, Comparative Effectiveness Research, Coronary Artery Disease therapy, Coronary Stenosis therapy, Disease Progression, Female, Heart Disease Risk Factors, Humans, Male, Middle Aged, Myocardial Revascularization, Predictive Value of Tests, Prognosis, Prospective Studies, Risk Assessment, Severity of Illness Index, Time Factors, Computed Tomography Angiography, Coronary Angiography, Coronary Artery Disease diagnostic imaging, Coronary Stenosis diagnostic imaging, Coronary Vessels diagnostic imaging, Multidetector Computed Tomography, Plaque, Atherosclerotic
- Abstract
Purpose: To provide comparative prognostic information of coronary atherosclerotic plaque volume and stenosis assessment in patients with suspected coronary artery disease (CAD)., Methods: We followed 372 patients with suspected or known CAD enrolled in the CORE320 study for 2 years after baseline 320-detector row cardiac CT scanning and invasive quantitative coronary angiography (QCA). CT images were analyzed for coronary calcium scanning (CACS), semi-automatically derived total percent atheroma volume (PAV), segment stenosis score (SSS), in addition to traditional stenosis assessment (≥ 50%) by CT and QCA for (1) 30-day revascularization and (2) major adverse cardiac events (MACE). Area under the receiver operating characteristic curve (AUC) was used to compare accuracy of risk prediction., Results: Sixty percent of patients had obstructive CAD by QCA with 23% undergoing 30-day revascularization and 9% experiencing MACE at 2 years. Most late events (20/32) were revascularization procedures. Prediction of 30-day revascularization was modest (AUC range 0.67-0.78) but improved after excluding patients with known CAD (AUC range 0.73-0.86, p < 0.05 for all). Similarly, prediction of MACE improved after excluding patients with known CAD (AUC range 0.58-0.73 vs. 0.63-0.77). CT metrics of atherosclerosis burden performed overall similarly but stenosis assessment was superior for predicting 30-day revascularization., Conclusions: Angiographic and coronary atherosclerotic plaque metrics perform only modestly well for predicting 30-day revascularization and 2-year MACE in high risk patients but improve after excluding patients with known CAD. Atherosclerotic plaque metrics did not yield incremental value over stenosis assessment for predicting events that predominantly consisted of revascularization procedures., Clinical Trial Registration: NCT00934037.
- Published
- 2020
- Full Text
- View/download PDF
22. Patient Preferences for Coronary CT Angiography with Stress Perfusion, SPECT, or Invasive Coronary Angiography.
- Author
-
Minhas A, Dewey M, Vavere AL, Tanami Y, Ostovaneh MR, Laule M, Rochitte CE, Niinuma H, Kofoed KF, Geleijns J, Hoe J, Chen MY, Kitagawa K, Nomura C, Clouse ME, Rybicki FJ, Tan SY, Paul N, Matheson M, Cox C, Rief M, Maier P, Feger S, Plotkin M, and Schönenberger E
- Subjects
- Aged, Female, Humans, Male, Middle Aged, Pain, Procedural, Prospective Studies, Computed Tomography Angiography adverse effects, Computed Tomography Angiography methods, Computed Tomography Angiography psychology, Coronary Angiography adverse effects, Coronary Angiography methods, Coronary Angiography psychology, Patient Preference statistics & numerical data
- Abstract
Background Patient preference is pivotal for widespread adoption of tests in clinical practice. Patient preferences for invasive versus other noninvasive tests for coronary artery disease are not known. Purpose To compare patient acceptance and preferences for noninvasive and invasive cardiac imaging in North and South America, Asia, and Europe. Materials and Methods This was a prospective 16-center trial in 381 study participants undergoing coronary CT angiography with stress perfusion, SPECT, and invasive coronary angiography (ICA). Patient preferences were collected by using a previously validated questionnaire translated into eight languages. Responses were converted to ordinal scales and were modeled with generalized linear mixed models. Results In patients in whom at least one test was associated with pain, CT and SPECT showed reduced median pain levels, reported on 0-100 visual analog scales, from 20 for ICA (interquartile range [IQR], 4-50) to 6 for CT (IQR, 0-27.5) and 5 for SPECT (IQR, 0-25) ( P < .001). Patients from Asia reported significantly more pain than patients from other continents for ICA (median, 25; IQR, 10-50; P = .01), CT (median, 10; IQR, 0-30; P = .02), and SPECT (median, 7; IQR, 0-28; P = .03). Satisfaction with preparation differed by continent and test ( P = .01), with patients from Asia reporting generally lower ratings. Patients from North America had greater percentages of "very high" or "high" satisfaction than patients from other continents for ICA (96% vs 82%, respectively; P < .001) and SPECT (95% vs 79%, respectively; P = .04) but not for CT (89% vs 86%, respectively; P = .70). Among all patients, CT was preferred by 54% of patients, compared with 18% for SPECT and 28% for ICA ( P < .001). Conclusion For cardiac imaging, patients generally favored CT angiography with stress perfusion, while study participants from Asia generally reported lowest satisfaction. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Woodard and Nguyen in this issue.
- Published
- 2019
- Full Text
- View/download PDF
23. Coronary Calcium Characteristics as Predictors of Major Adverse Cardiac Events in Symptomatic Patients: Insights From the CORE 320 Multinational Study.
- Author
-
Lo-Kioeng-Shioe MS, Vavere AL, Arbab-Zadeh A, Schuijf JD, Rochitte CE, Chen MY, Rief M, Kofoed KF, Clouse ME, Scholte AJ, Miller JM, Betoko A, Blaha MJ, Cox C, Deckers JW, and Lima JAC
- Subjects
- Aged, Aged, 80 and over, Coronary Artery Disease epidemiology, Coronary Artery Disease metabolism, Coronary Vessels metabolism, Female, Follow-Up Studies, Global Health, Humans, Incidence, Male, Middle Aged, Myocardial Perfusion Imaging, Predictive Value of Tests, Prospective Studies, Risk Factors, Survival Rate trends, Vascular Calcification epidemiology, Vascular Calcification metabolism, Calcium metabolism, Computed Tomography Angiography methods, Coronary Angiography methods, Coronary Artery Disease diagnosis, Coronary Vessels diagnostic imaging, Risk Assessment methods, Vascular Calcification diagnosis
- Abstract
Background The predictive value of coronary artery calcium ( CAC ) has been widely studied; however, little is known about specific characteristics of CAC that are most predictive. We aimed to determine the independent associations of Agatston score, CAC volume, CAC area, CAC mass, and CAC density score with major adverse cardiac events in patients with suspected coronary artery disease. Methods and Results A total of 379 symptomatic participants, aged 45 to 85 years, referred for invasive coronary angiography, who underwent coronary calcium scanning and computed tomography angiography as part of the CORE 320 (Combined Noninvasive Coronary Angiography and Myocardial Perfusion Imaging Using 320 Detector Computed Tomography) study, were included. Agatston score, CAC volume, area, mass, and density were computed on noncontrast images. Stenosis measurements were made on contrast-enhanced images. The primary outcome of 2-year major adverse cardiac events (30 revascularizations [>182 days of index catheterization], 5 myocardial infarctions, 1 cardiac death, 9 hospitalizations, and 1 arrhythmia) occurred in 32 patients (8.4%). Associations were estimated using multivariable proportional means models. Median age was 62 (interquartile range, 56-68) years, 34% were women, and 56% were white. In separate models, the Agatston, volume, and density scores were all significantly associated with higher risk of major adverse cardiac events after adjustment for age, sex, race, and statin use; density was the strongest predictor in all CAC models. CAC density did not provide incremental value over Agatston score after adjustment for diameter stenosis, age, sex, and race. Conclusions In symptomatic patients, CAC density was the strongest independent predictor of major adverse cardiac events among CAC scores, but it did not provide incremental value beyond the Agatston score after adjustment for diameter stenosis.
- Published
- 2019
- Full Text
- View/download PDF
24. Elastic modulus and toughness of orb spider glycoprotein glue.
- Author
-
Opell BD, Clouse ME, and Andrews SF
- Subjects
- Animals, Biomechanical Phenomena, Elastic Modulus, Female, Fibronectins chemistry, Humidity, Insect Proteins chemistry, Species Specificity, Spiders physiology, Viscosity, Adhesives chemistry, Glycoproteins chemistry, Spiders chemistry
- Abstract
An orb web's prey capture thread features tiny glue droplets, each formed of an adhesive glycoprotein core surrounded by an aqueous layer. Small molecules in the aqueous layer confer droplet hygroscopicity and maintain glycoprotein viscoelasticity, causing droplet volume and glycoprotein performance to track changes in environmental humidity. Droplet extension combines with that of a thread's supporting flagelliform fibers to sum the adhesive forces of multiple droplets, creating an effective adhesive system. We combined measurements of the force on an extending droplet, as gauged by the deflection of its support line, with measurements of glycoprotein volume and droplet extension to determine the Young's modulus (E) and toughness of three species' glycoproteins. We did this at five relative humidities between 20-90% to assess the effect of humidity on these properties. When droplets of a thread span extend, their extensions are constrained and their glycoprotein filaments remain covered by aqueous material. This was also the case during the first extension phase of the individual droplets that we examined. However, as extension progressed, the aqueous layer was progresses disrupted, exposing the glycoprotein. During the first extension phase E ranged from 0.00003 GPa, a value similar to that of fibronectin, a glycoprotein that anchors cells in the extracellular matrix, to 0.00292 GPa, a value similar to that of resilin in insect ligaments. Second phase E increased 4.7-19.4-fold. When compared at the same humidity the E of each species' glycoprotein was less than 5% of the value reported for its flagelliform fibers. This difference may facilitate the coordinated extension of these two capture thread components that is responsible for summing the thread's adhesive forces., Competing Interests: The authors have declared that no competing interests exist.
- Published
- 2018
- Full Text
- View/download PDF
25. Prognostic Value of Combined CT Angiography and Myocardial Perfusion Imaging versus Invasive Coronary Angiography and Nuclear Stress Perfusion Imaging in the Prediction of Major Adverse Cardiovascular Events: The CORE320 Multicenter Study.
- Author
-
Chen MY, Rochitte CE, Arbab-Zadeh A, Dewey M, George RT, Miller JM, Niinuma H, Yoshioka K, Kitagawa K, Sakuma H, Laham R, Vavere AL, Cerci RJ, Mehra VC, Nomura C, Kofoed KF, Jinzaki M, Kuribayashi S, Scholte AJ, Laule M, Tan SY, Hoe J, Paul N, Rybicki FJ, Brinker JA, Arai AE, Matheson MB, Cox C, Clouse ME, Di Carli MF, and Lima JAC
- Subjects
- Aged, Female, Hemodynamics, Humans, Male, Middle Aged, Prognosis, Prospective Studies, Sensitivity and Specificity, Surveys and Questionnaires, Survival Analysis, Computed Tomography Angiography, Coronary Angiography, Coronary Artery Disease diagnostic imaging, Coronary Artery Disease therapy, Myocardial Perfusion Imaging, Tomography, Emission-Computed, Single-Photon
- Abstract
Purpose To compare the prognostic importance (time to major adverse cardiovascular event [MACE]) of combined computed tomography (CT) angiography and CT myocardial stress perfusion imaging with that of combined invasive coronary angiography (ICA) and stress single photon emission CT myocardial perfusion imaging. Materials and Methods This study was approved by all institutional review boards, and written informed consent was obtained. Between November 2009 and July 2011, 381 participants clinically referred for ICA and aged 45-85 years were enrolled in the Combined Noninvasive Coronary Angiography and Myocardial Perfusion Imaging Using 320-Detector Row Computed Tomography (CORE320) prospective multicenter diagnostic study. All images were analyzed in blinded independent core laboratories, and a panel of physicians adjudicated all adverse events. MACE was defined as revascularization (>30 days after index ICA), myocardial infarction, or cardiac death; hospitalization for chest pain or congestive heart failure; or arrhythmia. Late MACE was defined similarly, except for patients who underwent revascularization within the first 182 days after ICA, who were excluded. Comparisons of 2-year survival (time to MACE) used standard Kaplan-Meier curves and restricted mean survival times bootstrapped with 2000 replicates. Results An MACE (49 revascularizations, five myocardial infarctions, one cardiac death, nine hospitalizations for chest pain or congestive heart failure, and one arrhythmia) occurred in 51 of 379 patients (13.5%). The 2-year MACE-free rates for combined CT angiography and CT perfusion findings were 94% negative for coronary artery disease (CAD) versus 82% positive for CAD and were similar to combined ICA and single photon emission CT findings (93% negative for CAD vs 77% positive for CAD, P < .001 for both). Event-free rates for CT angiography and CT perfusion versus ICA and single photon emission CT for either positive or negative results were not significantly different for MACE or late MACE (P > .05 for all). The area under the receiver operating characteristic curve (AUC) for combined CT angiography and CT perfusion (AUC = 68; 95% confidence interval [CI]: 62, 75) was similar (P = .36) to that for combined ICA and single photon emission CT (AUC = 71; 95% CI: 65, 79) in the identification of MACE at 2-year follow-up. Conclusion Combined CT angiography and CT perfusion enables similar prediction of 2-year MACE, late MACE, and event-free survival similar to that enabled by ICA and single photon emission CT.
© RSNA, 2017 Online supplemental material is available for this article.- Published
- 2017
- Full Text
- View/download PDF
26. Total coronary atherosclerotic plaque burden assessment by CT angiography for detecting obstructive coronary artery disease associated with myocardial perfusion abnormalities.
- Author
-
Kishi S, Magalhães TA, Cerci RJ, Matheson MB, Vavere A, Tanami Y, Kitslaar PH, George RT, Brinker J, Miller JM, Clouse ME, Lemos PA, Niinuma H, Reiber JH, Rochitte CE, Rybicki FJ, Di Carli MF, Cox C, Lima JA, and Arbab-Zadeh A
- Subjects
- Aged, Algorithms, Area Under Curve, Automation, Coronary Artery Disease physiopathology, Coronary Stenosis physiopathology, Coronary Vessels physiopathology, Feasibility Studies, Female, Hemodynamics, Humans, Male, Middle Aged, Observer Variation, Plaque, Atherosclerotic, Predictive Value of Tests, Prospective Studies, ROC Curve, Radiographic Image Interpretation, Computer-Assisted, Reproducibility of Results, Severity of Illness Index, Tomography, Emission-Computed, Single-Photon, Computed Tomography Angiography, Coronary Angiography methods, Coronary Artery Disease diagnostic imaging, Coronary Circulation, Coronary Stenosis diagnostic imaging, Coronary Vessels diagnostic imaging, Multidetector Computed Tomography, Myocardial Perfusion Imaging methods
- Abstract
Background: Total atherosclerotic plaque burden assessment by CT angiography (CTA) is a promising tool for diagnosis and prognosis of coronary artery disease (CAD) but its validation is restricted to small clinical studies. We tested the feasibility of semi-automatically derived coronary atheroma burden assessment for identifying patients with hemodynamically significant CAD in a large cohort of patients with heterogenous characteristics., Methods: This study focused on the CTA component of the CORE320 study population. A semi-automated contour detection algorithm quantified total coronary atheroma volume defined as the difference between vessel and lumen volume. Percent atheroma volume (PAV = [total atheroma volume/total vessel volume] × 100) was the primary metric for assessment (n = 374). The area under the receiver operating characteristic curve (AUC) determined the diagnostic accuracy for identifying patients with hemodynamically significant CAD defined as ≥50% stenosis by quantitative coronary angiography and associated myocardial perfusion abnormality by SPECT., Results: Of 374 patients, 139 (37%) had hemodynamically significant CAD. The AUC for PAV was 0.78 (95% confidence interval [CI] 0.73-0.83) compared with 0.84 [0.79-0.88] by standard expert CTA interpretation (p = 0.02). Accuracy for both CTA (0.91 [0.87, 0.96]) and PAV (0.86 [0.81-0.91]) increased after excluding patients with history of CAD (p < 0.01 for both). Bland-Altman analysis revealed good agreement between two observers (bias of 280.2 mm(3) [161.8, 398.7])., Conclusions: A semi-automatically derived index of total coronary atheroma volume yields good accuracy for identifying patients with hemodynamically significant CAD, though marginally inferior to CTA expert reading. These results convey promise for rapid, reliable evaluation of clinically relevant CAD., (Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.)
- Published
- 2016
- Full Text
- View/download PDF
27. Incremental diagnostic accuracy of computed tomography myocardial perfusion imaging over coronary angiography stratified by pre-test probability of coronary artery disease and severity of coronary artery calcification: The CORE320 study.
- Author
-
Sharma RK, Arbab-Zadeh A, Kishi S, Chen MY, Magalhães TA, George RT, Dewey M, Rybicki FJ, Kofoed KF, de Roos A, Tan SY, Matheson M, Vavere A, Cox C, Clouse ME, Miller JM, Brinker JA, Arai AE, Di Carli MF, Rochitte CE, and Lima JA
- Subjects
- Aged, Aged, 80 and over, Female, Follow-Up Studies, Humans, Male, Middle Aged, Predictive Value of Tests, Prospective Studies, ROC Curve, Reproducibility of Results, Severity of Illness Index, Coronary Angiography methods, Coronary Artery Disease diagnosis, Coronary Vessels diagnostic imaging, Multidetector Computed Tomography methods, Myocardial Perfusion Imaging methods, Tomography, Emission-Computed, Single-Photon methods, Vascular Calcification diagnosis
- Abstract
Background: Myocardial CT perfusion (CTP) has been validated as an incremental diagnostic predictor over coronary computed tomography angiography (CTA) in assessing hemodynamically significant stenosis., Objectives: To assess the diagnostic performance of CTA and CTP alone versus combined CTA-CTP stratified by Morise's pre-test probability and coronary artery calcium (CAC, Agatston) score., Methods: 381 individuals (153 low/intermediate-risk for CAD, 83 high-risk, 145 known CAD) were further stratified based on CAC score cut-offs of 1-399 and ≥400. Area under the curve for receiver operating characteristics (AUC) was calculated to assess the diagnostic performance. Reference standards were QCA≥50% stenosis+corresponding SPECT summed stress score ≥1., Results: In both pre-test risk groups with an Agatston score of 1-399, AUCs of CTA-CTP were not significantly different than that from CTA alone. In the low/intermediate-risk group with CAC score 1-399, AUC for CTA-CTP (89) was higher than that for CTP (76, p=0.003) alone. In the same group with CAC score ≥400, AUCs were higher for CTA-CTP (97) than that for CTA (88, p=0.030) and CTP (83, p=0.033). In high risk/known CAD patients with CAC 1-399, diagnostic performance for CTA-CTP (77) was superior to CTP (71, p=0.037) alone. In the high risk/known CAD group with CAC score ≥400, AUCs for combined imaging were higher (86) than that for CTA (75, p<0.001) as well as CTP (78, p=0.020)., Conclusions: The incremental diagnostic accuracy of CTP over CTA persists in patients across severity spectra of pre-test probability of CAD and coronary artery calcification. In patients with severe coronary calcification (CAC score≥400), combined CTA-CTP has better diagnostic accuracy than CTA and CTP alone., (Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.)
- Published
- 2015
- Full Text
- View/download PDF
28. Accuracy of Computed Tomographic Angiography and Single-Photon Emission Computed Tomography-Acquired Myocardial Perfusion Imaging for the Diagnosis of Coronary Artery Disease.
- Author
-
Arbab-Zadeh A, Di Carli MF, Cerci R, George RT, Chen MY, Dewey M, Niinuma H, Vavere AL, Betoko A, Plotkin M, Cox C, Clouse ME, Arai AE, Rochitte CE, Lima JA, Brinker J, and Miller JM
- Subjects
- Aged, Aged, 80 and over, Female, Humans, Male, Middle Aged, Prospective Studies, ROC Curve, Reproducibility of Results, Coronary Angiography methods, Coronary Artery Disease diagnosis, Multidetector Computed Tomography methods, Myocardial Perfusion Imaging methods, Tomography, Emission-Computed, Single-Photon methods
- Abstract
Background: Establishing the diagnosis of coronary artery disease (CAD) in symptomatic patients allows appropriately allocating preventative measures. Single-photon emission computed tomography (CT)-acquired myocardial perfusion imaging (SPECT-MPI) is frequently used for the evaluation of CAD, but coronary CT angiography (CTA) has emerged as a valid alternative., Methods and Results: We compared the accuracy of SPECT-MPI and CTA for the diagnosis of CAD in 391 symptomatic patients who were prospectively enrolled in a multicenter study after clinical referral for cardiac catheterization. The area under the receiver operating characteristic curve was used to evaluate the diagnostic accuracy of CTA and SPECT-MPI for identifying patients with CAD defined as the presence of ≥1 coronary artery with ≥50% lumen stenosis by quantitative coronary angiography. Sensitivity to identify patients with CAD was greater for CTA than SPECT-MPI (0.92 versus 0.62, respectively; P<0.001), resulting in greater overall accuracy (area under the receiver operating characteristic curve, 0.91 [95% confidence interval, 0.88-0.94] versus 0.69 [0.64-0.74]; P<0.001). Results were similar in patients without previous history of CAD (area under the receiver operating characteristic curve, 0.92 [0.89-0.96] versus 0.67 [0.61-0.73]; P<0.001) and also for the secondary end points of ≥70% stenosis and multivessel disease, as well as subgroups, except for patients with a calcium score of ≥400 and those with high-risk anatomy in whom the overall accuracy was similar because CTA's superior sensitivity was offset by lower specificity in these settings. Radiation doses were 3.9 mSv for CTA and 9.8 for SPECT-MPI (P<0.001)., Conclusions: CTA is more accurate than SPECT-MPI for the diagnosis of CAD as defined by conventional angiography and may be underused for this purpose in symptomatic patients., Clinical Trial Registration: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00934037., (© 2015 American Heart Association, Inc.)
- Published
- 2015
- Full Text
- View/download PDF
29. The impact of UVB radiation on the glycoprotein glue of orb-weaving spider capture thread.
- Author
-
Stellwagen SD, Opell BD, and Clouse ME
- Subjects
- Adaptation, Physiological, Animals, Ecosystem, Glycoproteins chemistry, Predatory Behavior, Silk, Species Specificity, Spiders chemistry, Glycoproteins radiation effects, Spiders physiology, Ultraviolet Rays
- Abstract
Many spider orb-webs are exposed to sunlight and the potentially damaging effects of ultraviolet B (UVB) radiation. We examined the effect of UVB on the viscoelastic glycoprotein core of glue droplets deposited on the prey capture threads of these webs, hypothesizing that webs built by species that occupy sunny habitats are less susceptible to UVB damage than are webs built by species that prefer shaded forest habitats or by nocturnal species. Threads were tested shortly after being collected in the early morning and after being exposed to UVB energy equivalent to a day of summer sun and three times this amount. Droplets kept in a dark chamber allowed us to evaluate post-production changes. Droplet volume was unaffected by treatments, indicating that UVB did not damage the hygroscopic compounds in the aqueous layer that covers droplets. UVB exposure did not affect energies of droplet extension for species from exposed and partially to mostly shaded habitats (Argiope aurantia, Leucauge venusta and Verrucosa arenata). However, UVB exposure reduced the energy of droplet extension in Micrathena gracilis from shaded forests and Neoscona crucifera, which forages at night. Only in L. venusta did the energy of droplet extension increase after the dark treatment, suggesting endogenous molecular alignment. This study adds UVB irradiation to the list of factors (humidity, temperature and strain rate) known to affect the performance of spider glycoprotein glue, factors that must be more fully understood if adhesives that mimic spider glycoprotein glue are to be produced., (© 2015. Published by The Company of Biologists Ltd.)
- Published
- 2015
- Full Text
- View/download PDF
30. Combined coronary angiography and myocardial perfusion by computed tomography in the identification of flow-limiting stenosis - The CORE320 study: An integrated analysis of CT coronary angiography and myocardial perfusion.
- Author
-
Magalhães TA, Kishi S, George RT, Arbab-Zadeh A, Vavere AL, Cox C, Matheson MB, Miller JM, Brinker J, Di Carli M, Rybicki FJ, Rochitte CE, Clouse ME, and Lima JA
- Subjects
- Aged, Aged, 80 and over, Coronary Stenosis physiopathology, Coronary Vessels physiopathology, Feasibility Studies, Female, Humans, Male, Middle Aged, Predictive Value of Tests, Prospective Studies, Radiographic Image Interpretation, Computer-Assisted, Reproducibility of Results, Severity of Illness Index, Tomography, Emission-Computed, Single-Photon, Coronary Angiography methods, Coronary Circulation, Coronary Stenosis diagnostic imaging, Coronary Vessels diagnostic imaging, Myocardial Perfusion Imaging methods, Tomography, X-Ray Computed methods
- Abstract
Background: The combination of coronary CT angiography (CTA) and myocardial CT perfusion (CTP) is gaining increasing acceptance, but a standardized approach to be implemented in the clinical setting is necessary., Objectives: To investigate the accuracy of a combined coronary CTA and myocardial CTP comprehensive protocol compared to coronary CTA alone, using a combination of invasive coronary angiography and single photon emission CT as reference., Methods: Three hundred eighty-one patients included in the CORE320 trial were analyzed in this study. Flow-limiting stenosis was defined as the presence of ≥50% stenosis by invasive coronary angiography with a related perfusion defect by single photon emission CT. The combined CTA + CTP definition of disease was the presence of a ≥50% stenosis with a related perfusion defect. All data sets were analyzed by 2 experienced readers, aligning anatomic findings by CTA with perfusion defects by CTP., Results: Mean patient age was 62 ± 6 years (66% male), 27% with prior history of myocardial infarction. In a per-patient analysis, sensitivity for CTA alone was 93%, specificity was 54%, positive predictive value was 55%, negative predictive value was 93%, and overall accuracy was 69%. After combining CTA and CTP, sensitivity was 78%, specificity was 73%, negative predictive value was 64%, positive predictive value was 0.85%, and overall accuracy was 75%. In a per-vessel analysis, overall accuracy of CTA alone was 73% compared to 79% for the combination of CTA and CTP (P < .0001 for difference)., Conclusions: Combining coronary CTA and myocardial CTP findings through a comprehensive protocol is feasible. Although sensitivity is lower, specificity and overall accuracy are higher than assessment by coronary CTA when compared against a reference standard of stenosis with an associated perfusion defect., (Copyright © 2015 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.)
- Published
- 2015
- Full Text
- View/download PDF
31. Lack of association between epicardial fat volume and extent of coronary artery calcification, severity of coronary artery disease, or presence of myocardial perfusion abnormalities in a diverse, symptomatic patient population: results from the CORE320 multicenter study.
- Author
-
Tanami Y, Jinzaki M, Kishi S, Matheson M, Vavere AL, Rochitte CE, Dewey M, Chen MY, Clouse ME, Cox C, Kuribayashi S, Lima JA, and Arbab-Zadeh A
- Subjects
- Aged, Aged, 80 and over, Asia, Brazil, Coronary Artery Disease physiopathology, Coronary Stenosis physiopathology, Coronary Vessels physiopathology, Europe, Female, Humans, Linear Models, Logistic Models, Male, Middle Aged, Multivariate Analysis, Myocardial Perfusion Imaging methods, North America, Odds Ratio, Predictive Value of Tests, Prognosis, Severity of Illness Index, Tomography, Emission-Computed, Single-Photon, Vascular Calcification physiopathology, Adipose Tissue diagnostic imaging, Coronary Angiography methods, Coronary Artery Disease diagnostic imaging, Coronary Circulation, Coronary Stenosis diagnostic imaging, Coronary Vessels diagnostic imaging, Multidetector Computed Tomography, Pericardium diagnostic imaging, Vascular Calcification diagnostic imaging
- Abstract
Background: Epicardial fat may play a role in the pathogenesis of coronary artery disease (CAD). We explored the relationship of epicardial fat volume (EFV) with the presence and severity of CAD or myocardial perfusion abnormalities in a diverse, symptomatic patient population., Methods and Results: Patients (n=380) with known or suspected CAD who underwent 320-detector row computed tomographic angiography, nuclear stress perfusion imaging, and clinically driven invasive coronary angiography for the CORE320 international study were included. EFV was defined as adipose tissue within the pericardial borders as assessed by computed tomography using semiautomatic software. We used linear and logistic regression models to assess the relationship of EFV with coronary calcium score, stenosis severity by quantitative coronary angiography, and myocardial perfusion abnormalities by single photon emission computed tomography (SPECT). Median EFV among patients (median age, 62.6 years) was 102 cm(3) (interquartile range: 53). A coronary calcium score of ≥1 was present in 83% of patients. Fifty-nine percent of patients had ≥1 coronary artery stenosis of ≥50% by quantitative coronary angiography, and 49% had abnormal myocardial perfusion results by SPECT. There were no significant associations between EFV and coronary artery calcium scanning, presence severity of ≥50% stenosis by quantitative coronary angiography, or abnormal myocardial perfusion by SPECT., Conclusions: In a diverse population of symptomatic patients referred for invasive coronary angiography, we did not find associations of EFV with the presence and severity of CAD or with myocardial perfusion abnormalities. The clinical significance of quantifying EFV remains uncertain but may relate to the pathophysiology of acute coronary events rather than the presence of atherosclerotic disease., (© 2015 American Heart Association, Inc.)
- Published
- 2015
- Full Text
- View/download PDF
32. Myocardial CT Perfusion Imaging and SPECT for the Diagnosis of Coronary Artery Disease: A Head-to-Head Comparison from the CORE320 Multicenter Diagnostic Performance Study.
- Author
-
George RT, Mehra VC, Chen MY, Kitagawa K, Arbab-Zadeh A, Miller JM, Matheson MB, Vavere AL, Kofoed KF, Rochitte CE, Dewey M, Yaw TS, Niinuma H, Brenner W, Cox C, Clouse ME, Lima JA, and Di Carli M
- Published
- 2015
- Full Text
- View/download PDF
33. Comprehensive assessment of radiation dose estimates for the CORE320 study.
- Author
-
Rybicki FJ, Mather RT, Kumamaru KK, Brinker J, Chen MY, Cox C, Matheson MB, Dewey M, DiCarli MF, Miller JM, Geleijns J, George RT, Paul N, Texter J, Vavere A, Yaw TS, Lima JA, and Clouse ME
- Subjects
- Aged, Female, Humans, Internationality, Male, Middle Aged, Reproducibility of Results, Sensitivity and Specificity, Absorption, Radiation, Coronary Angiography statistics & numerical data, Coronary Stenosis diagnostic imaging, Radiation Dosage, Tomography, Emission-Computed, Single-Photon statistics & numerical data, Tomography, X-Ray Computed statistics & numerical data, Whole-Body Counting statistics & numerical data
- Abstract
OBJECTIVE. The purpose of this study was to comprehensively study estimated radiation doses for subjects included in the main analysis of the Combined Non-invasive Coronary Angiography and Myocardial Perfusion Imaging Using 320 Detector Computed Tomography (CORE320) study ( ClinicalTrials.gov identifier NCT00934037), a clinical trial comparing combined CT angiography (CTA) and perfusion CT with the reference standard catheter angiography plus myocardial perfusion SPECT. SUBJECTS AND METHODS. Prospectively acquired data on 381 CORE320 subjects were analyzed in four groups of testing related to radiation exposure. Radiation dose estimates were compared between modalities for combined CTA and perfusion CT with respect to covariates known to influence radiation exposure and for the main clinical outcomes defined by the trial. The final analysis assessed variations in radiation dose with respect to several factors inherent to the trial. RESULTS. The mean radiation dose estimate for the combined CTA and perfusion CT protocol (8.63 mSv) was significantly (p < 0.0001 for both) less than the average dose delivered from SPECT (10.48 mSv) and the average dose from diagnostic catheter angiography (11.63 mSv). There was no significant difference in estimated CTA-perfusion CT radiation dose for subjects who had false-positive or false-negative results in the CORE320 main analyses in a comparison with subjects for whom the CTA-perfusion CT findings were in accordance with the reference standard SPECT plus catheter angiographic findings. CONCLUSION. Radiation dose estimates from CORE320 support clinical implementation of a combined CT protocol for assessing coronary anatomy and myocardial perfusion.
- Published
- 2015
- Full Text
- View/download PDF
34. Nuclear stress perfusion imaging versus computed tomography coronary angiography for identifying patients with obstructive coronary artery disease as defined by conventional angiography: insights from the CorE-64 multicenter study.
- Author
-
Tanami Y, Miller JM, Vavere AL, Rochitte CE, Dewey M, Niinuma H, Clouse ME, Cox C, Brinker J, Lima JA, and Arbab-Zadeh A
- Abstract
We investigated the diagnostic accuracy of computed tomography angiography (CTA) versus myocardial perfusion imaging (MPI) for detecting obstructive coronary artery disease (CAD) as defined by conventional quantitative coronary angiography (QCA). Sixty-three patients who were enrolled in the CorE-64 multicenter study underwent CTA, MPI, and QCA imaging. All subjects were referred for cardiac catheterization with suspected or known coronary artery disease. The diagnostic accuracy of quantitative CTA and MPI for identifying patients with 50% or greater coronary arterial stenosis by QCA was evaluated using receiver operating characteristic (ROC) analysis. Pre-defined subgroups were patients with known CAD and those with a calcium score of 400 or over. Diagnostic accuracy by ROC analysis revealed greater area under the curve (AUC) for CTA than MPI for all 63 patients: 0.95 [95% confidence interval (CI): 0.89-0.100] vs 0.65 (95%CI: 0.53-0.77), respectively (P<0.01). Sensitivity, specificity, positive and negative predictive values were 0.93, 0.95, 0.97, 0.88, respectively, for CTA and 0.85, 0.45, 0.74, 0.63, respectively, for MPI. In 48 patients without known CAD, AUC was 0.96 for CTA and to 0.67 for SPECT (P<0.01). There was no significant difference in AUC for CTA in patients with calcium score below 400 versus over 400 (0.93 vs 0.95), but AUC was different for SPECT (0.61 vs 0.95; P<0.01). In a direct comparison, CTA is markedly superior to MPI for detecting obstructive coronary artery disease in patients. Even in subgroups traditionally more challenging for CTA, SPECT does not offer similarly good diagnostic accuracy. CTA may be considered the non-invasive test of choice if diagnosis of obstructive CAD is the purpose of imaging.
- Published
- 2014
35. Myocardial CT perfusion imaging and SPECT for the diagnosis of coronary artery disease: a head-to-head comparison from the CORE320 multicenter diagnostic performance study.
- Author
-
George RT, Mehra VC, Chen MY, Kitagawa K, Arbab-Zadeh A, Miller JM, Matheson MB, Vavere AL, Kofoed KF, Rochitte CE, Dewey M, Yaw TS, Niinuma H, Brenner W, Cox C, Clouse ME, Lima JA, and Di Carli M
- Subjects
- Aged, Aged, 80 and over, Coronary Angiography, Female, Humans, Male, Middle Aged, Prospective Studies, Coronary Artery Disease diagnostic imaging, Myocardial Perfusion Imaging methods, Tomography, Emission-Computed, Single-Photon methods, Tomography, X-Ray Computed methods
- Abstract
Purpose: To compare the diagnostic performance of myocardial computed tomographic (CT) perfusion imaging and single photon emission computed tomography (SPECT) perfusion imaging in the diagnosis of anatomically significant coronary artery disease (CAD) as depicted at invasive coronary angiography., Materials and Methods: This study was approved by the institutional review board. Written informed consent was obtained from all patients. Sixteen centers enrolled 381 patients from November 2009 to July 2011. Patients underwent rest and adenosine stress CT perfusion imaging and rest and either exercise or pharmacologic stress SPECT before and within 60 days of coronary angiography. Images from CT perfusion imaging, SPECT, and coronary angiography were interpreted at blinded, independent core laboratories. The primary diagnostic parameter was the area under the receiver operating characteristic curve (Az). Sensitivity and specificity were calculated with use of prespecified cutoffs. The reference standard was a stenosis of at least 50% at coronary angiography as determined with quantitative methods., Results: CAD was diagnosed in 229 of the 381 patients (60%). The per-patient sensitivity and specificity for the diagnosis of CAD (stenosis ≥50%) were 88% (202 of 229 patients) and 55% (83 of 152 patients), respectively, for CT perfusion imaging and 62% (143 of 229 patients) and 67% (102 of 152 patients) for SPECT, with Az values of 0.78 (95% confidence interval: 0.74, 0.82) and 0.69 (95% confidence interval: 0.64, 0.74) (P = .001). The sensitivity of CT perfusion imaging for single- and multivessel CAD was higher than that of SPECT, with sensitivities for left main, three-vessel, two-vessel, and one-vessel disease of 92%, 92%, 89%, and 83%, respectively, for CT perfusion imaging and 75%, 79%, 68%, and 41%, respectively, for SPECT., Conclusion: The overall performance of myocardial CT perfusion imaging in the diagnosis of anatomic CAD (stenosis ≥50%), as demonstrated with the Az, was higher than that of SPECT and was driven in part by the higher sensitivity for left main and multivessel disease.
- Published
- 2014
- Full Text
- View/download PDF
36. Assessment of liver fat in an obese patient population using noncontrast CT fat percent index.
- Author
-
Jon AF, Cheema AR, Khan AN, Raptopoulos V, Hauser T, Nasser I, Welty FK, Karellas A, and Clouse ME
- Subjects
- Aged, Female, Humans, Male, Middle Aged, Fats analysis, Fatty Liver diagnostic imaging, Liver diagnostic imaging, Obesity diagnostic imaging, Tomography, X-Ray Computed methods
- Abstract
Objective: To develop a simplified method to quantify liver fat using computed tomography (CT) fat % index (CTFPI) compared to liver spleen method (CTL/S, CTL-S)., Methods: Noncontrast CT of the liver was performed in 89 patients (overweight, obese, severely obese) to quantify fat, using the following: CTFPI=[(65-patient HU)/65]×100, normal live r=65 HU., Results: There was a strong linear correlation between CTFPI and the standard method of assessing liver fat using CTL/S (r=-0.901), CTL-S (r=-0.911). Hepatic HU and CTFPI were significantly different in the severely obese group compared to other two groups (P<.05)., Conclusion: Significant correlation indicates equal diagnostic accuracy of the two methods in appropriately calibrated scanners., (Copyright © 2014 Elsevier Inc. All rights reserved.)
- Published
- 2014
- Full Text
- View/download PDF
37. Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography: the CORE320 study.
- Author
-
Rochitte CE, George RT, Chen MY, Arbab-Zadeh A, Dewey M, Miller JM, Niinuma H, Yoshioka K, Kitagawa K, Nakamori S, Laham R, Vavere AL, Cerci RJ, Mehra VC, Nomura C, Kofoed KF, Jinzaki M, Kuribayashi S, de Roos A, Laule M, Tan SY, Hoe J, Paul N, Rybicki FJ, Brinker JA, Arai AE, Cox C, Clouse ME, Di Carli MF, and Lima JA
- Subjects
- Aged, Coronary Stenosis physiopathology, Female, Hemodynamics physiology, Humans, Male, Middle Aged, Multidetector Computed Tomography, Myocardial Perfusion Imaging methods, Prospective Studies, ROC Curve, Sensitivity and Specificity, Coronary Stenosis diagnostic imaging, Tomography, Emission-Computed, Single-Photon methods
- Abstract
Aims: To evaluate the diagnostic power of integrating the results of computed tomography angiography (CTA) and CT myocardial perfusion (CTP) to identify coronary artery disease (CAD) defined as a flow limiting coronary artery stenosis causing a perfusion defect by single photon emission computed tomography (SPECT)., Methods and Results: We conducted a multicentre study to evaluate the accuracy of integrated CTA-CTP for the identification of patients with flow-limiting CAD defined by ≥50% stenosis by invasive coronary angiography (ICA) with a corresponding perfusion deficit on stress single photon emission computed tomography (SPECT/MPI). Sixteen centres enroled 381 patients who underwent combined CTA-CTP and SPECT/MPI prior to conventional coronary angiography. All four image modalities were analysed in blinded independent core laboratories. The prevalence of obstructive CAD defined by combined ICA-SPECT/MPI and ICA alone was 38 and 59%, respectively. The patient-based diagnostic accuracy defined by the area under the receiver operating characteristic curve (AUC) of integrated CTA-CTP for detecting or excluding flow-limiting CAD was 0.87 [95% confidence interval (CI): 0.84-0.91]. In patients without prior myocardial infarction, the AUC was 0.90 (95% CI: 0.87-0.94) and in patients without prior CAD the AUC for combined CTA-CTP was 0.93 (95% CI: 0.89-0.97). For the combination of a CTA stenosis ≥50% stenosis and a CTP perfusion deficit, the sensitivity, specificity, positive predictive, and negative predicative values (95% CI) were 80% (72-86), 74% (68-80), 65% (58-72), and 86% (80-90), respectively. For flow-limiting disease defined by ICA-SPECT/MPI, the accuracy of CTA was significantly increased by the addition of CTP at both the patient and vessel levels., Conclusions: The combination of CTA and perfusion correctly identifies patients with flow limiting CAD defined as ≥50 stenosis by ICA causing a perfusion defect by SPECT/MPI.
- Published
- 2014
- Full Text
- View/download PDF
38. Influence of image acquisition on radiation dose and image quality: full versus narrow phase window acquisition using 320 MDCT.
- Author
-
Khosa F, Khan A, Nasir K, Shuaib W, Budoff M, Blankstein R, and Clouse ME
- Subjects
- Female, Humans, Male, Middle Aged, Reproducibility of Results, Sensitivity and Specificity, Coronary Angiography methods, Coronary Artery Disease diagnostic imaging, Multidetector Computed Tomography methods, Radiation Dosage, Radiographic Image Enhancement methods, Radiographic Image Interpretation, Computer-Assisted methods
- Abstract
Purpose: To compare radiation dose and image quality using predefined narrow phase window versus complete phase window with dose modulation during R-R using 320-row MDCTA., Methods: 114 patients underwent coronary CTA study using 320-row MDCT scanner. 87 patients with mean age (61 + 13 years), mean BMI (29 + 6), and mean heart rate (HR) (58 + 7 bpm) were imaged at predefined 66-80% R-R interval and then reconstructed at 75% while 27 patients with mean age (63 + 16 years), mean BMI (28 + 5), and mean HR (57 + 7 bpm) were scanned throughout the complete R-R interval with tube current modulation. The effective dose (ED) was calculated from dose length product (DLP) and conversion k (0.014 mSv/mGy/cm). Image quality was assessed using a three-point ordinal scale (1 = excellent, 2 = good, and 3 = nondiagnostic)., Results: Both groups were statistically similar to each other with reference of HR (P = 0.59), BMI (P = 0.17), and tube current mAs (P = 0.68). The median radiation dose was significantly higher in those scanned with complete R-R phase window versus narrow phase window (P < 0.0001). Independently of patient and scan parameters, increased phase window was associated with higher radiation dose (P < 0.001). Image quality was better among those scanned with narrow phase window versus complete phase window (P < 0.0001)., Conclusion: Our study supports that good HR control and predefined narrow window acquisition result in lower radiation dose without compromising diagnostic image quality for coronary disease evaluation.
- Published
- 2013
- Full Text
- View/download PDF
39. Patterns of coronary arterial lesion calcification by a novel, cross-sectional CT angiographic assessment.
- Author
-
Cerci R, Vavere AL, Miller JM, Yoneyama K, Rochitte CE, Dewey M, Niinuma H, Clouse ME, Laham R, Bush DE, Shapiro EP, Lardo AC, Cox C, Brinker J, Lima JA, and Arbab-Zadeh A
- Subjects
- Aged, Female, Humans, Male, Middle Aged, Plaque, Atherosclerotic, Predictive Value of Tests, Prognosis, Reproducibility of Results, Severity of Illness Index, Coronary Angiography methods, Coronary Artery Disease diagnostic imaging, Coronary Stenosis diagnostic imaging, Coronary Vessels diagnostic imaging, Multidetector Computed Tomography, Vascular Calcification diagnostic imaging
- Abstract
To investigate the patterns and diagnostic implications of coronary arterial lesion calcification by CT angiography (CTA) using a novel, cross-sectional grading method, we studied 371 patients enrolled in the CorE-64 study who underwent CTA and invasive angiography for detecting coronary artery stenoses by quantitative coronary angiography (QCA). The number of quadrants involving calcium on a cross-sectional view for ≥ 30 and ≥ 50 % lesions in 4,511 arterial segments was assessed by CTA according to: noncalcified, mild (one-quadrant), moderate (two-quadrant), severe (three-quadrant) and very severe (four-quadrant calcium). Area under the receiver operating characteristic curve (AUC) were used to evaluate CTA diagnostic accuracy and agreement versus. QCA for plaque types. Only 4 % of ≥ 50 % stenoses by QCA were very severely calcified while 43 % were noncalcified. AUC for CTA to detect ≥ 50 % stenoses by QCA for non-calcified, mildly, moderately, severely, and very severely calcified plaques were 0.90, 0.88, 0.83, 0.76 and 0.89, respectively (P < 0.05). In 198 lesions with severe calcification, the presence or absence of a visible residual lumen by CTA was associated with ≥ 50 % stenosis by QCA in 20.3 and 76.9 %, respectively. Kappa was 0.93 for interobserver variability in evaluating plaque calcification. We conclude that calcification of individual coronary artery lesions can be reliably graded using CTA. Most ≥ 50 % coronary artery stenoses are not or only mildly calcified. If no residual lumen is seen on CTA, calcified lesions are predictive of ≥ 50 % stenoses and vice versa. CTA diagnostic accuracy for detecting ≥ 50 % stenoses is reduced in lesions with more than mild calcification due to lower specificity.
- Published
- 2013
- Full Text
- View/download PDF
40. Predictors of inaccurate coronary arterial stenosis assessment by CT angiography.
- Author
-
Yan RT, Miller JM, Rochitte CE, Dewey M, Niinuma H, Clouse ME, Vavere AL, Brinker J, Lima JA, and Arbab-Zadeh A
- Subjects
- Diagnostic Errors, Female, Humans, Male, Middle Aged, Predictive Value of Tests, Prospective Studies, ROC Curve, Reproducibility of Results, Severity of Illness Index, Coronary Angiography methods, Coronary Stenosis diagnostic imaging, Multidetector Computed Tomography methods
- Abstract
Objectives: This study sought to investigate the clinical and imaging characteristics associated with diagnostic inaccuracy of computed tomography angiography (CTA) for detecting obstructive coronary artery disease (CAD) defined by quantitative coronary angiography (QCA)., Background: Although diagnostic performance metrics of CTA have been reported, there are sparse data on predictors of diagnostic inaccuracy by CTA., Methods: The clinical characteristics of 291 patients (mean age: 59 ± 10 years; female: 25.8%) enrolled in the multicenter CorE-64 (Coronary Artery Evaluation Using 64-Row Multi-detector Computed Tomography Angiography) study were examined. Pre-defined CTA segment-level characteristics of all true-positive (N = 237), false-positive (N = 115), false-negative (FN) (N = 159), and a random subset of true-negative segments (N = 511) for ≥50% stenosis with QCA as the reference standard were blindly abstracted in a central core laboratory. Factors independently associated with corresponding levels of CTA diagnostic inaccuracies on a patient level and coronary artery segment level were determined using multivariable logistic regression models and generalized estimating equations, respectively., Results: An Agatston calcium score of ≥1 per patient (odds ratio [OR]: 5.2; 95% confidence interval [CI]: 1.1 to 24.6) and the presence of within-segment calcification (OR: 10.2; 95% CI: 5.2 to 19.8) predicted false-positive diagnoses. Conversely, absence of within-segment calcification was an independent predictor of an FN diagnosis (OR: 2.0; 95% CI: 1.2 to 3.5). Prior percutaneous revascularization was independently associated with patient-level misdiagnosis of obstructive CAD (OR: 4.2; 95% CI: 1.6 to 11.2). Specific segment characteristics on CTA, notably segment tortuosity (OR: 3.5; 95% CI: 2.4 to 5.1), smaller luminal caliber (OR: 0.48; 95% CI: 0.36 to 0.63 per 1-mm increment), and juxta-arterial vein conspicuity (OR: 2.1; 95% CI: 1.4 to 3.2), were independently associated with segment-level misdiagnoses. Attaining greater intraluminal contrast enhancement independently lowered the risk of an FN diagnosis (OR: 0.96; 95% CI: 0.94 to 0.99 per 10-Hounsfield unit increment)., Conclusions: We identified clinical and readily discernible imaging characteristics on CTA predicting inaccurate CTA diagnosis of obstructive CAD defined by QCA. Knowledge and appropriate considerations of these features may improve the diagnostic accuracy in clinical CTA interpretation. (Diagnostic Accuracy of Multi-Detector Spiral Computed Tomography Angiography Using 64 Detectors [CORE-64]; NCT00738218)., (Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.)
- Published
- 2013
- Full Text
- View/download PDF
41. Comparison of coronary plaque subtypes in male and female patients using 320-row MDCTA.
- Author
-
Khosa F, Khan AN, Nasir K, Bedayat A, Malik Z, Jon AF, Cheema AR, Clouse ME, and Welty FK
- Subjects
- Aged, Calcinosis diagnostic imaging, Calcinosis pathology, Coronary Artery Disease diagnostic imaging, Coronary Artery Disease pathology, Coronary Stenosis diagnostic imaging, Coronary Stenosis pathology, Female, Humans, Male, Middle Aged, Plaque, Atherosclerotic diagnostic imaging, Retrospective Studies, Tomography, X-Ray Computed methods, Plaque, Atherosclerotic pathology
- Abstract
Objective: Determine plaque subtype and volume difference in male and female patients with obstructive and non-obstructive CAD using 320-row MDCTA., Materials and Methods: 128 patients with suspected CAD underwent MDCTA. All studies were divided into two groups based on disease severity. 0-70% stenosis (non-obstructive CAD) & >70% (obstructive). All were compared for plaque quantity and subtypes by gender. Main arteries, RCA, LM, LAD and LCX were analyzed using Vitrea 5.2 software to quantify fatty, fibrous and calcified plaque. Thresholds for coronary plaque quantification (volume in mm(3)) were preset at 35 ± 12 HU for fatty, 90 ± 24 HU for fibrous and >130 HU for calcified/mixed plaque and analyzed using STATA software., Results: Total plaque burden in 118 patients [65M: 53F] was significantly higher in all arteries in males compared to females with non-obstructive disease. Total plaque volume for males vs. females was: RCA: 10.10 ± 5.02 mm(3) vs. 6.89 ± 2.75 mm(3), respectively, p = 0.001; LAD: 7.21 ± 3.38 mm(3) vs. 5.89 ± 1.93 mm(3), respectively, p = 0.04; LCX: 9.13 ± 3.27 mm(3) vs. 7.16 ± 1.73 mm(3), respectively, p = 0.002; LM 15.13 ± 4.51 mm(3) vs. 11.85 ± 4.03 mm(3), respectively, p = 0.001. In sub-analyses, males had significantly more fibrous and fatty plaque in LM, LAD & LCX than females. However in the RCA, only fibrous plaque was significantly greater in males. Calcified plaque volume was not significantly different in both genders. Only 8% of patients had obstructive CAD (>70% stenosis); there was no significant difference in plaque volume or subtypes., Conclusion: In patients with non-obstructive CAD, males were found to have significantly higher total coronary plaque volume with predominance of fibrous and fatty subtypes compared to females of the same age and BMI. There was no significant difference in plaque subtype or volume in patients with obstructive disease., (Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.)
- Published
- 2013
- Full Text
- View/download PDF
42. Quantitative coronary arterial stenosis assessment by multidetector CT and invasive coronary angiography for identifying patients with myocardial perfusion abnormalities.
- Author
-
Godoy GK, Vavere A, Miller JM, Chahal H, Niinuma H, Lemos P, Hoe J, Paul N, Clouse ME, Ramos CD, Lima JA, and Arbab-Zadeh A
- Subjects
- Aged, Female, Humans, Male, Middle Aged, Tomography, Emission-Computed, Single-Photon, Coronary Angiography methods, Coronary Circulation, Coronary Stenosis diagnostic imaging, Multidetector Computed Tomography methods
- Abstract
Background: Semi-quantitative stenosis assessment by coronary CT angiography only modestly predicts stress-induced myocardial perfusion abnormalities. The performance of quantitative CT angiography (QCTA) for identifying patients with myocardial perfusion defects remains unclear., Methods: CorE-64 is a multicenter, international study to assess the accuracy of 64-slice QCTA for detecting ≥50% coronary arterial stenoses by quantitative coronary angiography (QCA). Patients referred for cardiac catheterization with suspected or known coronary artery disease were enrolled. Area under the receiver-operating-characteristic curve (AUC) was used to evaluate the diagnostic accuracy of the most severe coronary artery stenosis in a subset of 63 patients assessed by QCTA and QCA for detecting myocardial perfusion abnormalities on exercise or pharmacologic stress SPECT., Results: Diagnostic accuracy of QCTA for identifying patients with myocardial perfusion abnormalities by SPECT revealed an AUC of 0.71, compared to 0.72 by QCA (P = .75). AUC did not improve after excluding studies with fixed myocardial perfusion abnormalities and total coronary arterial occlusions. Optimal stenosis threshold for QCTA was 43% yielding a sensitivity of 0.81 and specificity of 0.50, respectively, compared to 0.75 and 0.69 by QCA at a threshold of 59%. Sensitivity and specificity of QCTA to identify patients with both obstructive lesions and myocardial perfusion defects were 0.94 and 0.77, respectively., Conclusions: Coronary artery stenosis assessment by QCTA or QCA only modestly predicts the presence and the absence of myocardial perfusion abnormalities by SPECT. Confounding variables affecting the relationship between coronary anatomy and myocardial perfusion likely account for some of the observed discrepancies between coronary angiography and SPECT results.
- Published
- 2012
- Full Text
- View/download PDF
43. Influence of image acquisition settings on radiation dose and image quality in coronary angiography by 320-detector volume computed tomography: the CORE320 pilot experience.
- Author
-
Yoneyama K, Vavere AL, Cerci R, Ahmed R, Arai AE, Niinuma H, Rybicki FJ, Rochitte CE, Clouse ME, George RT, Lima JA, and Arbab-Zadeh A
- Abstract
The objective of this study was to investigate the impact of image acquisition settings and patients' characteristics on image quality and radiation dose for coronary angiography by 320-row computed tomography (CT). CORE320 is a prospective study to investigate the diagnostic performance of 320-detector CT for detecting coronary artery disease and associated myocardial ischemia. A run-in phase in 65 subjects was conducted to test the adequacy of the computed tomography angiography (CTA) acquisition protocol. Tube current, exposure window, and number of cardiac beats per acquisition were adjusted according to subjects' gender, heart rate, and body mass index (BMI). Main outcome measures were image quality, assessed by contrast/noise measurements and qualitatively on a 4-point scale, and radiation dose, estimated by the dose-length-product. Average heart rate at image acquisition was 55.0±7.3 bpm. Median Agatston calcium score was 27.0 (interquartile range 1-330). All scans were prospectively triggered. Single heart beat image acquisition was obtained in 61 of 65 studies (94%). Sixty-one studies (94%) and 437 of 455 arterial segments (96%) were of diagnostic image quality. Estimated radiation dose was significantly greater in obese (5.3±0.4 mSv) than normal weight (4.6±0.3 mSv) or overweight (4.7±0.3 mSv) subjects (P<0.001). BMI was the strongest factor influencing image quality (odds ratio=1.457, P=0.005). The CORE320 CTA image acquisition protocol achieved a good balance between image quality and radiation dose for a 320-detector CT system. However, image quality in obese subjects was reduced compared to normal weight subjects, possibly due to tube voltage/current restrictions mandated by the study protocol.
- Published
- 2012
- Full Text
- View/download PDF
44. Prevalence of non-cardiac pathology on clinical transthoracic echocardiography.
- Author
-
Khosa F, Warraich H, Khan A, Mahmood F, Markson L, Clouse ME, and Manning WJ
- Subjects
- Academic Medical Centers, Adult, Aged, Cholelithiasis diagnostic imaging, Cholelithiasis epidemiology, Cohort Studies, Comorbidity, Cysts diagnostic imaging, Cysts epidemiology, Databases, Factual, Echocardiography methods, Female, Heart Diseases diagnostic imaging, Heart Diseases epidemiology, Heart Diseases physiopathology, Hemangioma diagnostic imaging, Hemangioma epidemiology, Humans, Inpatients statistics & numerical data, Liver Diseases diagnostic imaging, Liver Diseases epidemiology, Magnetic Resonance Imaging methods, Male, Middle Aged, Outpatients statistics & numerical data, Prevalence, Retrospective Studies, Risk Assessment, Sensitivity and Specificity, Echocardiography statistics & numerical data, Heart Failure diagnostic imaging, Heart Failure epidemiology, Incidental Findings, Ventricular Dysfunction, Left diagnostic imaging, Ventricular Dysfunction, Left epidemiology
- Abstract
Background: Non-cardiac findings (NCFs) are seen in more than a third of cardiac computed tomographic and cardiac magnetic resonance imaging studies. The prevalence and importance of NCFs in transthoracic echocardiographic (TTE) imaging is unknown. The aim of this study was to determine the prevalence of NCFs on TTE imaging., Methods: The subcostal images of all comprehensive adult TTE studies performed at one institution in December 2008 were retrospectively reviewed for NCFs by a radiologist with fellowship training in cardiovascular and abdominal radiology and blinded to the TTE report findings and clinical histories. Additional TTE image orientations were assessed in a subset of 300 studies. NCFs were categorized as benign (e.g., simple hepatic cyst), indeterminate (e.g., ascites), or worrisome (e.g., liver metastases). If an indeterminate or worrisome NCF was identified, the patient's electronic medical record was reviewed to determine if the NCF was previously known., Results: Of 1,008 TTE studies (443 inpatient, 565 outpatient) in 922 patients, 77 NCFs were identified in 69 patients (7.5%). These included 20 benign (26%), 52 indeterminate (67%), and five worrisome (7%) NCFs. Intermediate and worrisome NCFs were more common in inpatient TTE studies (9% vs 3% outpatient, P = .002). The additional views demonstrated 2% more NCFs. Record review demonstrated that 60% of worrisome and 67% of indeterminate NCFs were previously known. No unknown NCF ultimately led to a change in patient management., Conclusions: Clinical TTE studies demonstrate NCFs in 7.5% of all patients, with an increased prevalence on inpatient studies. Although 75% of NCFs were potentially management changing, the majority of these were previously known and very unlikely to lead to management changes. Further study is needed to validate these findings in other populations and to assess their clinical impact., (Copyright © 2012 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.)
- Published
- 2012
- Full Text
- View/download PDF
45. Diagnostic performance of combined noninvasive coronary angiography and myocardial perfusion imaging using 320 row detector computed tomography: design and implementation of the CORE320 multicenter, multinational diagnostic study.
- Author
-
Vavere AL, Simon GG, George RT, Rochitte CE, Arai AE, Miller JM, Di Carli M, Arbab-Zadeh A, Dewey M, Niinuma H, Laham R, Rybicki FJ, Schuijf JD, Paul N, Hoe J, Kuribyashi S, Sakuma H, Nomura C, Yaw TS, Kofoed KF, Yoshioka K, Clouse ME, Brinker J, Cox C, and Lima JA
- Subjects
- Aged, Aged, 80 and over, Brazil, Canada, Coronary Artery Disease physiopathology, Europe, Female, Hemodynamics, Humans, Japan, Male, Middle Aged, Predictive Value of Tests, Prognosis, Prospective Studies, Radiographic Image Interpretation, Computer-Assisted, Severity of Illness Index, Singapore, United States, Coronary Angiography methods, Coronary Artery Disease diagnostic imaging, Coronary Circulation, Myocardial Perfusion Imaging methods, Research Design, Tomography, X-Ray Computed
- Abstract
Multidetector coronary computed tomography angiography (CTA) is a promising modality for widespread clinical application because of its noninvasive nature and high diagnostic accuracy as found in previous studies using 64 to 320 simultaneous detector rows. It is, however, limited in its ability to detect myocardial ischemia. In this article, we describe the design of the CORE320 study ("Combined coronary atherosclerosis and myocardial perfusion evaluation using 320 detector row computed tomography"). This prospective, multicenter, multinational study is unique in that it is designed to assess the diagnostic performance of combined 320-row CTA and myocardial CT perfusion imaging (CTP) in comparison with the combination of invasive coronary angiography and single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI). The trial is being performed at 16 medical centers located in 8 countries worldwide. CT has the potential to assess both anatomy and physiology in a single imaging session. The co-primary aim of the CORE320 study is to define the per-patient diagnostic accuracy of the combination of coronary CTA and myocardial CTP to detect physiologically significant coronary artery disease compared with (1) the combination of conventional coronary angiography and SPECT-MPI and (2) conventional coronary angiography alone. If successful, the technology could revolutionize the management of patients with symptomatic CAD., (Copyright © 2011 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.)
- Published
- 2011
- Full Text
- View/download PDF
46. Coronary artery stenoses: accuracy of 64-detector row CT angiography in segments with mild, moderate, or severe calcification--a subanalysis of the CORE-64 trial.
- Author
-
Vavere AL, Arbab-Zadeh A, Rochitte CE, Dewey M, Niinuma H, Gottlieb I, Clouse ME, Bush DE, Hoe JW, de Roos A, Cox C, Lima JA, and Miller JM
- Subjects
- Aged, Female, Humans, Male, Middle Aged, Prospective Studies, Reproducibility of Results, Severity of Illness Index, Calcinosis diagnostic imaging, Coronary Angiography methods, Coronary Stenosis diagnostic imaging, Tomography, X-Ray Computed
- Abstract
Purpose: To evaluate the influence of cross-sectional arc calcification on the diagnostic accuracy of computed tomography (CT) angiography compared with conventional coronary angiography for the detection of obstructive coronary artery disease (CAD)., Materials and Methods: Institutional Review Board approval and written informed consent were obtained from all centers and participants for this HIPAA-compliant study. Overall, 4511 segments from 371 symptomatic patients (279 men, 92 women; median age, 61 years [interquartile range, 53-67 years]) with clinical suspicion of CAD from the CORE-64 multicenter study were included in the analysis. Two independent blinded observers evaluated the percentage of diameter stenosis and the circumferential extent of calcium (arc calcium). The accuracy of quantitative multidetector CT angiography to depict substantial (≥ 50%) stenoses was assessed by using quantitative coronary angiography (QCA). Cross-sectional arc calcium was rated on a segment level as follows: noncalcified or mild (< 90°), moderate (90°-180°), or severe (> 180°) calcification. Univariable and multivariable logistic regression, receiver operation characteristic curve, and clustering methods were used for statistical analyses., Results: A total of 1099 segments had mild calcification, 503 had moderate calcification, 338 had severe calcification, and 2571 segments were noncalcified. Calcified segments were highly associated (P < .001) with disagreement between CTA and QCA in multivariable analysis after controlling for sex, age, heart rate, and image quality. The prevalence of CAD was 5.4% in noncalcified segments, 15.0% in mildly calcified segments, 27.0% in moderately calcified segments, and 43.0% in severely calcified segments. A significant difference was found in area under the receiver operating characteristic curves (noncalcified: 0.86, mildly calcified: 0.85, moderately calcified: 0.82, severely calcified: 0.81; P < .05)., Conclusion: In a symptomatic patient population, segment-based coronary artery calcification significantly decreased agreement between multidetector CT angiography and QCA to detect a coronary stenosis of at least 50%., (© RSNA, 2011.)
- Published
- 2011
- Full Text
- View/download PDF
47. Diagnostic performance of combined noninvasive coronary angiography and myocardial perfusion imaging using 320-MDCT: the CT angiography and perfusion methods of the CORE320 multicenter multinational diagnostic study.
- Author
-
George RT, Arbab-Zadeh A, Cerci RJ, Vavere AL, Kitagawa K, Dewey M, Rochitte CE, Arai AE, Paul N, Rybicki FJ, Lardo AC, Clouse ME, and Lima JA
- Subjects
- Aged, Aged, 80 and over, Contrast Media, Exercise Test, Female, Humans, Image Interpretation, Computer-Assisted methods, Male, Middle Aged, Predictive Value of Tests, Prospective Studies, Radiopharmaceuticals, Sensitivity and Specificity, Tomography, Emission-Computed, Single-Photon methods, Coronary Angiography methods, Coronary Disease diagnostic imaging, Tomography, X-Ray Computed methods
- Abstract
Objective: Coronary MDCT angiography has been shown to be an accurate noninvasive tool for the diagnosis of obstructive coronary artery disease (CAD). Its sensitivity and negative predictive value for diagnosing percentage of stenosis are unsurpassed compared with those of other noninvasive testing methods. However, in its current form, it provides no information regarding the physiologic impact of CAD and is a poor predictor of myocardial ischemia. CORE320 is a multicenter multinational diagnostic study with the primary objective to evaluate the diagnostic accuracy of 320-MDCT for detecting coronary artery luminal stenosis and corresponding myocardial perfusion deficits in patients with suspected CAD compared with the reference standard of conventional coronary angiography and SPECT myocardial perfusion imaging., Conclusion: We aim to describe the CT acquisition, reconstruction, and analysis methods of the CORE320 study.
- Published
- 2011
- Full Text
- View/download PDF
48. Comparison of radiation dose and image quality: 320-MDCT versus 64-MDCT coronary angiography.
- Author
-
Khan A, Khosa F, Nasir K, Yassin A, and Clouse ME
- Subjects
- Adult, Aged, Aged, 80 and over, Female, Humans, Male, Middle Aged, Radiometry, Reproducibility of Results, Sensitivity and Specificity, Tomography, X-Ray Computed instrumentation, Coronary Angiography methods, Coronary Artery Disease diagnostic imaging, Radiation Dosage, Tomography, X-Ray Computed methods
- Abstract
Objective: The purpose of this study was to compare radiation dose and image quality of 320- and 64-MDCT angiography using prospective gating., Materials and Methods: One hundred seventy-four patients underwent 320-MDCT, and 95 patients underwent 64-MDCT. The scan parameters for 320-MDCT were 120 kVp, 400 mA, and gantry rotation of 350 milliseconds; the parameters for 64-MDCT were 120 kVp, 600 mA, and gantry rotation of 350 milliseconds. Effective dose (ED) was calculated from the dose-length product and a conversion factor (k = 0.014 mSv / mGy × cm). Two observers independently assessed image quality using a 3-point scale, where 3 denotes excellent quality and 1 denotes nondiagnostic quality, using a 16-segment model. Discrepancies were settled by consensus., Results: The ED was significantly lower in patients undergoing 320-MDCT angiography, with a median ED of 4.4 mSv (interquartile range [IQR], 3.4-6.2 mSv), compared with 64-MDCT angiography, with a median ED of 6.2 mSv (IQR, 5.5-6.9 mSv) (p = 0.0001). In patients with a heart rate of 65 beats/min or less (92%), the median radiation dose using 320-MDCT was 4.1 mSv (IQR, 3.2-6.1 mSv), and that for 64-MDCT angiography was 6.2 mSv (IQR, 5.8-6.9 mSv) (p = 0.0001). In patients with heart rate greater than 65 beats/min (8%), the median dose was higher with 320-MDCT (8.7 mSv; IQR, 5.9-14.3 mSv) than with 64-MDCT (5.8 mSv; IQR, 5.3-6.7 mSv) (p = 0.02). Segmental image quality was significantly better for 320-MDCT (excellent or good quality, 96.66%; nondiagnostic quality, 0.1%) than for 64-MDCT angiography (excellent or good quality, 86%; nondiagnostic quality, 3.33%) (all p < 0.0001)., Conclusion: Image quality was good for both 320- and 64-MDCT angiography. Overall radiation dose was significantly lower in 320-MDCT angiography when the heart rate was 65 beats/min or less. Every effort should be made to control heart rate to minimize radiation dose.
- Published
- 2011
- Full Text
- View/download PDF
49. Prospective gating with 320-MDCT angiography: effect of volume scan length on radiation dose.
- Author
-
Khan A, Nasir K, Khosa F, Saghir A, Sarwar S, and Clouse ME
- Subjects
- Electrocardiography, Female, Humans, Male, Middle Aged, Retrospective Studies, Coronary Angiography, Coronary Artery Disease diagnostic imaging, Radiation Dosage, Tomography, X-Ray Computed methods
- Abstract
Objective: The purpose of this study was to evaluate the relation between radiation dose reduction and volume scan length for prospectively ECG-gated 320-MDCT angiography in the diagnosis of coronary artery disease., Materials and Methods: MDCT with prospective ECG gating was performed at one of the three volume scan lengths depending on heart length. Of 175 patients, 95 (55%; body mass index, 29 ± 5.9; mean heart rate, 59 ± 7 beats/min) underwent scanning at 160 mm; 46 (26%; body mass index, 30 ± 4.1; mean heart rate, 56 ± 5.74 beats/min) at 140 mm; and 34 (19%; body mass index, 30 ± 3.71; mean heart rate, 58 ± 3.96 beats/min) at 120 mm., Results: The median radiation doses were 6.5 mSv (95% CI, 6.03-7.2 mSv) for the 95 patients who underwent scanning at a volume scan length of 160 mm, 4.33 mSv (95% CI, 4.06-6.62 mSv) for the 46 patients who underwent scanning at 140 mm, and 3.47 mSv (95% CI, 3.15-3.62 mSv) for the 34 patients who underwent scanning at 120 mm. The reduction in scan length from 160 to 140 mm represented a reduction in scan length of 12.5% and the reduction to 120 mm a reduction of 25%. The median radiation dose was reduced 33% when volume scan length was changed to 140 mm and 47% when the length was changed to 120 mm., Conclusion: Dose optimization remains an important concern in cardiac CT, and for 320-MDCT angiography, substantial dose reduction can be achieved by reducing volume scan length so that it is in concert with the patient's heart length.
- Published
- 2011
- Full Text
- View/download PDF
50. Absorbed radiation dose in radiosensitive organs during coronary CT angiography using 320-MDCT: effect of maximum tube voltage and heart rate variations.
- Author
-
Nikolic B, Khosa F, Lin PJ, Khan AN, Sarwar S, Yam CS, Court LE, Raptopoulos V, and Clouse ME
- Subjects
- Breast radiation effects, Eye radiation effects, Female, Heart radiation effects, Heart Rate radiation effects, Humans, Least-Squares Analysis, Lung radiation effects, Male, Phantoms, Imaging, Risk Assessment, Thyroid Gland radiation effects, Coronary Angiography instrumentation, Radiation Dosage, Radiometry methods, Tomography, X-Ray Computed instrumentation
- Abstract
Objective: The purpose of this article is to estimate the absorbed radiation dose in radiosensitive organs during coronary MDCT angiography using 320-MDCT and to determine the effects of tube voltage variation and heart rate (HR) control on absorbed radiation dose., Materials and Methods: Semiconductor field effect transistor detectors were used to measure absorbed radiation doses for the thyroid, midbreast, breast, and midlung in an anthropomorphic phantom at 100, 120, and 135 kVp at two different HRs of 60 and 75 beats per minute (bpm) with a scan field of view of 320 mm, 400 mA, 320 × 0.5 mm detectors, and 160 mm collimator width (160 mm range). The paired Student's t test was used for data evaluation., Results: At 60 bpm, absorbed radiation doses for 100, 120, and 135 kVp were 13.41 ± 3.59, 21.7 ± 4.12, and 29.28 ± 5.17 mGy, respectively, for midbreast; 11.76 ± 0.58, 18.86 ± 1.06, and 24.82 ± 1.45 mGy, respectively, for breast; 12.19 ± 2.59, 19.09 ± 3.12, and 26.48 ± 5.0 mGy, respectively, for lung; and 0.37 ± 0.14, 0.69 ± 0.14, and 0.92 ± 0.2 mGy, respectively, for thyroid. Corresponding absorbed radiation doses for 75 bpm were 38.34 ± 2.02, 59.72 ± 3.13, and 77.8 ± 3.67 mGy for midbreast; 26.2 ± 1.74, 44 ± 1.11, and 52.84 ± 4.07 mGy for breast; 38.02 ± 1.58, 58.89 ± 1.68, and 78 ± 2.93 mGy for lung; and 0.79 ± 0.233, 1.04 ± 0.18, and 2.24 ± 0.52 mGy for thyroid. Absorbed radiation dose changes were significant for all organs for both tube voltage reductions as well as for HR control from 75 to 60 bpm at all tube voltage settings (p < 0.05). The absorbed radiation doses for the calcium score protocol were 11.2 ± 1.4 mGy for midbreast, 9.12 ± 0.48 mGy for breast, 10.36 ± 1.3 mGy for lung, and 0.4 ± 0.05 mGy for thyroid., Conclusion: CT angiography with 320-MDCT scanners results in absorbed radiation doses in radiosensitive organs that compare favorably to those previously reported. Significant dose reductions can be achieved by tube voltage reductions and HR control.
- Published
- 2010
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.