Highly Reliable MEMS Temperature Sensors for 275 ^ \circ\C Applications—Part 1: Design and Technology.

Authors :
Scott, Sean
Sadeghi, Farshid
Peroulis, Dimitrios
Source :
Journal of Microelectromechanical Systems. Feb2013, Vol. 22 Issue 1, p225-235. 11p.
Publication Year :
2013

Abstract

This paper presents the design, fabrication, packaging, and experimental characterization of the first temperature-sensitive MEMS capacitors for health monitoring applications up to 275 ^\circ\C. The capacitive sensor chip is 2 \times 2\ \mm^2 fabricated on a 500-\mu\m-thick Si wafer and comprises an array of 220 individual 10 \times 250 \ \mu\m^2 inherently robust bimorphs. This first part focuses on the fabrication and packaging, thermomechanical design, electromagnetic modeling, and technology of the unpackaged and packaged bimorph beams. On the thermomechanical part, the measured profiles match theoretically predicted profiles from 20 ^\circ\C to 250 ^ \circ\C within 4% and 3% at the beam midpoints and tips, respectively. Similarly, experimentally obtained capacitance changes for five separate packaged devices show a mean error of less than 3% and a maximum error of less than 5% from the theoretical model up to 165 ^\circ \C. The packaged sensors simultaneously achieve for the first time: 1) high temperature operation; 2) monotonic capacitance–temperature response from 20 ^\circ \C to 300 ^\circ\C; 3) hermetic sealing; 4) miniature size of 5.4 \times 5.4 \times 3.6\ \mm^3; and 5) capacitance quality factor of over 5000 at 20 ^\circ \C and 1000 at 160 ^\circ\C. Experimental results underline the tradeoffs between beam arrangement, attachment method to the package, and package to the quality factor of the device.\hfill[2011-0316] [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
10577157
Volume :
22
Issue :
1
Database :
Academic Search Index
Journal :
Journal of Microelectromechanical Systems
Publication Type :
Academic Journal
Accession number :
85214737
Full Text :
https://doi.org/10.1109/JMEMS.2012.2227947