Back to Search Start Over

Sub-micron resolution rf cavity beam position monitor system at the SACLA XFEL facility

Authors :
Maesaka, H.
Ego, H.
Inoue, S.
Matsubara, S.
Ohshima, T.
Shintake, T.
Otake, Y.
Source :
Nuclear Instruments & Methods in Physics Research Section A. Dec2012, Vol. 696, p66-74. 9p.
Publication Year :
2012

Abstract

Abstract: We have developed and constructed a C-band (4.760GHz) rf cavity beam position monitor (RF-BPM) system for the XFEL facility at SPring-8, SACLA. The demanded position resolution of the RF-BPM is less than , because an electron beam and x-rays must be overlapped within precision in the undulator section for sufficient FEL interaction between the electrons and x-rays. In total, 57 RF-BPMs, including IQ demodulators and high-speed waveform digitizers for signal processing, were produced and installed into SACLA. We evaluated the position resolutions of 20 RF-BPMs in the undulator section by using a 7GeV electron beam having a 0.1nC bunch charge. The position resolution was measured to be less than , which was sufficient for the XFEL lasing in the wavelength region of 0.1nm, or shorter. [Copyright &y& Elsevier]

Details

Language :
English
ISSN :
01689002
Volume :
696
Database :
Academic Search Index
Journal :
Nuclear Instruments & Methods in Physics Research Section A
Publication Type :
Academic Journal
Accession number :
82899098
Full Text :
https://doi.org/10.1016/j.nima.2012.08.088