74 results on '"efluente industrial"'
Search Results
2. Disminución de la Concentración de Cromo VI Contenido en un Efluente Industrial Empleando la Técnica de Electrolisis.
- Author
-
Valenzuela Castañeda, Jordan Fernando, Martínez Gómez, Victor Jesus, Puente Siller, Damaris Margarita, Josefina Rodríguez Rosales, María Dolores, Alcázar Medina, Félix Alonso, Rojas Montes, Jaime Cristóbal, and Martínez Casillas, Diana Cristina
- Abstract
Copyright of Congreso Internacional de Investigacion Academia Journals is the property of PDHTech, LLC and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2022
3. Avaliação do processo UV/H2O2 no pós-tratamento de águas residuárias da indústria de papel e celulose
- Author
-
Cristiane Lisboa Giroletti, Jean Carlo Salomé dos Santos Menezes, Beatriz Lima Santos Klienchen Dalari, Fabiola Tomassoni, Flávio Rubens Lapolli, Maria Ángeles Lobo-Recio, and Maria Eliza Nagel-Hassemer
- Subjects
processo uv/h2o2 ,efluente industrial ,papel e celulose ,Environmental technology. Sanitary engineering ,TD1-1066 ,Environmental engineering ,TA170-171 ,Environmental sciences ,GE1-350 - Abstract
O segmento da produção industrial de papel e celulose é de grande relevância no desenvolvimento econômico e social do Brasil. Contudo, esse ramo de atividade também pode apresentar problemas de ordem ambiental, devido ao grande consumo de água e à geração de efluentes. Quando não tratados adequadamente, esses efluentes podem provocar impactos negativos e até mesmo danos irreparáveis. Dentre as técnicas mais promissoras voltadas ao tratamento de efluentes industriais, destacam-se os processos oxidativos avançados. O presente trabalho objetivou avaliar o desempenho do processo UV/H2O2 no pós-tratamento de efluentes de uma indústria de papel e celulose. Durante 120 minutos de irradiação UV, foram testadas seis concentrações de H2O2, que variaram entre 15 e 200 mg.L-1. Os resultados revelaram a efetividade do processo na remoção da DQO em 84% e da DBO5 em até 91%. A remoção de sólidos suspensos totais variou entre 80 e 100%. Para os sólidos totais, os índices de remoção ficaram ente 16 e 50%. O desempenho do processo UV/H2O2 foi influenciado pela disponibilidade de H2O2 e pelo tempo de irradiação UV.
- Published
- 2022
- Full Text
- View/download PDF
4. Remoção de contaminantes persistentes com biorreator de membrana e adsorção em carvão ativado
- Author
-
Josefa Daiana Araújo Lopes, Gabriela Paupitz Mendes, Amanda Paiva Farias, Rennio Felix de Sena, and Gilson Athayde Barbosa Júnior
- Subjects
biorreator ,efluente industrial ,herbicidas ,ultrafiltração ,Environmental technology. Sanitary engineering ,TD1-1066 ,Environmental engineering ,TA170-171 ,Environmental sciences ,GE1-350 - Abstract
Os agrotóxicos são exemplos de contaminantes emergentes, que se tornaram um dos grandes desafios em termos de contaminação ambiental. Embora apresentem risco potencial à saúde humana, esses contaminantes ainda não estão incluídos nos programas de monitoramento de rotina. Além disso, os processos convencionais de tratamento de efluentes não removem esses compostos. Nesse contexto, o presente estudo teve como objetivo avaliar a capacidade de remoção dos herbicidas 2,4-D e Metribuzin (MTZ) em um efluente industrial, utilizando um biorreator de membrana de ultrafiltração (BRM-UF) seguido de pós-tratamento com carvão ativado. Soluções padrão dos herbicidas foram adicionadas ao BRM, e o permeado foi analisado por meio do espectrofotômetro UV-Vís. Cloreto de sódio foi utilizado como traçador e seu controle foi feito por meio do condutivímetro. Em seguida, foram feitos ensaios de adsorção com carvão ativado. De acordo com os resultados obtidos, pode-se afirmar que não foi verificado nenhum mecanismo de remoção dos herbicidas estudados. Logo, o BRM não foi efetivo na remoção destes. Já os carvões ativados utilizados no pós-tratamento apresentaram elevada eficiência na remoção do 2,4-D e MTZ.
- Published
- 2022
- Full Text
- View/download PDF
5. Avaliação do Efluente da Estação de Tratamento de Efluente de uma Indústria de Tintas Segundo as Legislações Ambientais Vigentes sobre a Emissão de Efluentes
- Author
-
Alyne Gonçalves Leite, Maria do Socorro Ribeiro Hortegal Filha, Carlos Ronald Pessoa Wanderley, Rossana Barros Silveira, and Adna Viana Dutra
- Subjects
Indústria de tintas ,Efluente industrial ,Estação de tratamento ,Legislação ambiental ,Resolução COEMA nº 02/2017. ,Social Sciences ,Science ,Medicine ,Agriculture ,Technology - Abstract
Dentre os setores mais poluentes no Brasil destaca-se o âmbito industrial da fabricação de tintas, por isso a necessidade que exista um eficiente tratamento dos efluentes, para que alcancem os parâmetros exigidos pelas normas e leis vigentes. O presente artigo foi realizado em uma Indústria de tintas, localizada no município de Maracanaú/CE e objetiva-se em avaliar o desempenho da ETE, tratando o efluente produzido. A metodologia utilizada seguiu basicamente cinco etapas: Caracterização da Indústria de Tintas, análise do processo produtivo, levantamento de dados, monitoramento da ETE, e tabulação dos dados. Nos resultados verificou-se que o a DQO encontra-se 365 mg/L acima do exigido. Conclui-se então que a indústria de Tintas deve incluir um processo de tratamento complementar em sua ETE, para aumentar o nível de remoção de DQO. Este trabalho serve de suporte e alerta para indústrias desse setor.
- Published
- 2019
- Full Text
- View/download PDF
6. Processo UV/H2 O2 aplicado como pós-tratamento de águas residuárias da indústria de papel e celulose
- Author
-
Cristiane Lisboa Giroletti, Jean Carlo Salomé dos Santos Menezes, Flávio Rubens Lapolli, Maria Ángeles Lobo-Recio, and Maria Eliza Nagel-Hassemer
- Subjects
processo oxidativo avançado ,radiação uv ,efluente industrial ,papel e celulose ,Environmental technology. Sanitary engineering ,TD1-1066 ,Environmental engineering ,TA170-171 ,Environmental sciences ,GE1-350 - Abstract
Desafios econômicos e ecológicos procedentes da crise hídrica e das restrições impostas pela legislação ambiental contribuíram recentemente para a expansão das aplicações dos processos oxidativos avançados como técnicas alternativas de tratamento de efluentes. O presente trabalho objetivou avaliar o processo UV/H2 O2 aplicado como pós-tratamento de águas residuárias da indústria de papel e celulose, sob diferentes concentrações de oxidante. Os resultados revelaram o potencial da aplicação do processo UV/ H2 O2 na oxidação de substâncias orgânicas com remoção da DBO5 de 85 a 92%. A remoção da cor foi total para todas as concentrações de H2 O2 . Para a turbidez, os índices de remoção variaram entre 41 e 83%. Na remoção dos compostos aromáticos, o processo reduziu em até 98% a aromaticidade do efluente, mostrando assim a efetividade do processo no tratamento dos efluentes da indústria de papel e celulose.
- Published
- 2018
- Full Text
- View/download PDF
7. MONITORAMENTO E RELACIONAMENTO DOS PARÂMETROS DQO E DBO5 EM AFLUENTE E ESGOTO TRATADO DAS CIDADES DE ITAJUBÁ E PEDRALVA, MG.
- Author
-
BUDEIZ, Victor and AGUIAR, André
- Subjects
- *
SEWAGE purification , *SEWAGE , *BIOCHEMICAL oxygen demand , *SEWAGE disposal plants , *CHEMICAL oxygen demand , *SANITATION - Abstract
One of the main characteristics evaluated in municipal sewage treatment is the organic matter content, usually based on the analysis of Chemical and Biochemical Oxygen Demands, COD, and BOD respectively. The objective of this work was to analyze and compare the relation between the COD and BOD parameters for raw sewage (effluent) and treated sewage of two wastewater treatment plants (WWTPs) of the cities of Itajubá and Pedralva, both localized in the south of Minas Gerais, Brazil. Due to the data obtained over two years from the state sanitation company, the analysis of ratios and linear correlation between COD and BOD5 were performed, as well as their removal (%) to verify the WWTP efficiencies. The COD/BOD5 value of 2.13 was obtained for the affluent of Itajubá city, while for Pedralva was 2.20. These values are common at the typical range of raw domestic wastewater, and no evidence of industrial contribution was found. The values of the linear correlation coefficient (R²) between the COD and BOD5 parameters for affluent of Itajubá and Pedralva were 0.8585 and 0.4863, respectively, suggesting that BOD5 value can be estimated from COD only in the first case (R²>0.8). For treated sewage samples from both WWTPs, this approach is not appropriate because the R² values were lower than 0.3. According to current state legislation (COPAM/CERH nº 01), the two WWTPs efficiently removed the BOD5, while Itajubá WWTP showed COD removal slightly below the stipulated. Following federal legislation (CONAMA nº 430), both WWTPs have efficiently removed BOD5. [ABSTRACT FROM AUTHOR]
- Published
- 2020
- Full Text
- View/download PDF
8. Avaliação da Influência do Coeficiente de Desoxigenação no Modelo de Autodepuração Utilizando Efluentes de Laticínio.
- Author
-
Moraes Guedes, Duwylho, Cuba Teran, Francisco Javier, and dos Santos Aguiar Guedes, Priscila Gracielle
- Subjects
- *
BODIES of water , *WASTEWATER treatment , *DAIRY plants , *DISSOLVED oxygen in water , *DEOXYGENATION , *SEWAGE - Abstract
The limitations of in-depth specific studies about industrial discharges have led more and more professionals to make use parameters that clash with reality, due to the adoption of tabulated coefficients which do not always correspond to the real characteristics of the aforementioned effluents. This study aims above all to determine the deoxygenation coefficient of the water body that receives the discharges of a dairy plant in the interior of the state of Goiás. A self-depuration study was also conducted along the lines of the Streeter-Phelps method, thanks to which it was possible to analyze the differences between the theoretical and experimental coefficients. The theoretical deoxygenation coefficient used was that found in the literature of Von Sperling for secondary treatment wastewater, varying between 0,12 d-1 (minimum), 0,18 d-1 (medium) and 0,24 d-1 (maximum), in which each of these values was corrected on the basis of the temperature of the effluent, resulting in K1 26°C = 0,16d-1, 0,24 d-1 e 0,32 d-1, respectively. As for the experimental coefficient, it was determined using the Thomas method. The figure found for coefficient K1 corrected on the basis of the temperature resulted in K1 26°C = 0,46 d-1. Thanks to the self-depuration data modeling, it was possible to establish that the industrial discharge had the major impact on the receiving water body, the experimental K1 26°C showed a smaller amount of critical concentration of dissolved oxygen and consequently, after the active decomposition zone, there was a gradual improvement in the levels of the dissolved oxygen by means of the experimental K1 26°C, which in turn led to the restoration of the initial characteristics of the clean waters zone in an area smaller when compared with the theoretical K126°C. [ABSTRACT FROM AUTHOR]
- Published
- 2019
- Full Text
- View/download PDF
9. Acute ecotoxicity on Daphnia magna to evaluate effluent samples of Kraft pulp mill treated by UV/H2O2 process.
- Author
-
Micheletto, Joicy, Monteiro Sampaio, Naiara Mariana Fiori, Ruiz, Henrique Zavattieri, Martins, Lucia Regina Rocha, de Liz, Marcus Vinicius, and de Freitas, Adriane Martins
- Subjects
LIGNINS ,DAPHNIA magna ,SULFATE pulping process ,PULP mills ,PULP mill waste disposal ,PAPER industry - Abstract
Copyright of Revista Ambiente e Água is the property of Revista Ambiente e Agua and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2019
- Full Text
- View/download PDF
10. Remoção de contaminantes persistentes com biorreator de membrana e adsorção em carvão ativado
- Author
-
Josefa Daiana Araújo Lopes, Gabriela Paupitz Mendes, Amanda Paiva Farias, Rennio Felix de Sena, and Gilson Athayde Barbosa Júnior
- Subjects
Environmental sciences ,biorreator ,herbicidas ,Environmental engineering ,GE1-350 ,General Medicine ,TA170-171 ,efluente industrial ,Environmental technology. Sanitary engineering ,TD1-1066 ,ultrafiltração - Abstract
Os agrotóxicos são exemplos de contaminantes emergentes, que se tornaram um dos grandes desafios em termos de contaminação ambiental. Embora apresentem risco potencial à saúde humana, esses contaminantes ainda não estão incluídos nos programas de monitoramento de rotina. Além disso, os processos convencionais de tratamento de efluentes não removem esses compostos. Nesse contexto, o presente estudo teve como objetivo avaliar a capacidade de remoção dos herbicidas 2,4-D e Metribuzin (MTZ) em um efluente industrial, utilizando um biorreator de membrana de ultrafiltração (BRM-UF) seguido de pós-tratamento com carvão ativado. Soluções padrão dos herbicidas foram adicionadas ao BRM, e o permeado foi analisado por meio do espectrofotômetro UV-Vís. Cloreto de sódio foi utilizado como traçador e seu controle foi feito por meio do condutivímetro. Em seguida, foram feitos ensaios de adsorção com carvão ativado. De acordo com os resultados obtidos, pode-se afirmar que não foi verificado nenhum mecanismo de remoção dos herbicidas estudados. Logo, o BRM não foi efetivo na remoção destes. Já os carvões ativados utilizados no pós-tratamento apresentaram elevada eficiência na remoção do 2,4-D e MTZ. Palavras-chave: Biorreator. Efluente industrial. Herbicidas. Ultrafiltração.
- Published
- 2021
11. TRATAMIENTO DE AGUAS RESIDUALES DE UNA INDUSTRIA PROCESADORA DE PESCADO EN REACTORES ANAERÓBICOS DISCONTINUOS
- Author
-
Julio César Marín Leal, Carlos Aníbal Chinga Panta, Abrahan Isaac Velásquez Ferrín, Pierre Andrés González Cabo, and Luz María Zambrano Rodríguez
- Subjects
efluente industrial ,materia biodegradable ,lodo anaerobio ,reactores discontinuos ,tratabilidad anaeróbica ,Engineering (General). Civil engineering (General) ,TA1-2040 ,Science - Abstract
En el presente trabajo se evaluó el tratamiento de las aguas residuales de una industria procesadorade pescado de la ciudad de Manta (Ecuador), en reactores anaeróbicos discontinuos, y se estableciósu adecuación a las normas ambientales vigentes en materia de vertido. Para ello, se realizaronensayos de laboratorio en reactores discontinuos de 1 L, con un tiempo de contacto de 24 h yprovistos de un lodo anaerobio procedente de una planta de tratamiento de aguas residualesdomésticas. Dicho efluente fue diluido con agua destilada en proporciones de 33%, 66% y 100%,correspondientes a las etapas I, II y III, respectivamente. Durante cada etapa se monitorearon los siguientes parámetros, de acuerdo con los métodos estándares: pH, alcalinidad total, DBO5.20,DQO, nitrito, amonio, nitrógeno total Kjeldahl (NTK), ortofostato, sulfato, sólidos suspendidostotales (SST) y sólidos suspendidos volátiles (SSV). Los resultados muestran porcentajes deremoción de materia orgánica, expresados como DBO5.20(37.9±4.1%; 41.8±7.6% y 46.2±3.2%) yDQO (34.7±9.7%; 36.9±9.2% y 43.8±4.1%, para las etapas I, II y III, respectivamente), relativamentebajos como resultado del origen del inóculo usado, así como del contenido relativo de sales en elefluente industrial. Las remociones de amonio, NTK y ortofosfato estuvieron entre 60-95%, 25-37% y 6-25%, respectivamente. Bajo las condiciones de los ensayos realizados, el efluente tratadorequiriere de la aplicación de un postratamiento para reducir el contenido de materia orgánica ynutrientes a los límites permisibles de descarga establecidos en la República de Ecuador.
- Published
- 2015
12. Evaluación de parámetros físico-químicos de una estación de tratamiento de efluentes de un matadero refrigerado en São Luís – MA
- Author
-
Bogéa, Nigell Silva, Braga, Risete Maria Queiroz Leão, and Andrade, Marcello Ádamis
- Subjects
Frigorífico ,Aguas residuales ,Industrial effluent ,Esgotamento sanitário ,Slaughterhouse ,Efluente industrial ,Sanitary sewage ,Mataderos ,Efluentes industriales - Abstract
Due to the large increase in operations and production, there has been a high production of waste in slaughterhouses in recent years, but when disordered and unsupervised, the treatment of these wastes can have harmful impacts on the environment. In this way, the study makes an evaluation of an existing Effluent Treatment Station (ETE) of a slaughterhouse in São Luís - MA, analyzing its chemical composition and comparing them to the SEMA Ordinance Nº 79/2013 of the state of Maranhão, CONAMA Resolution Nº. 430/2011 and CONAMA Resolution Nº. 357/2005. It is observed that the values of the slaughterhouse in question are close to those stipulated by CETESB, some being relatively lower, such as: oils and greases and suspended solids. However, it was possible to verify that the ETE has efficiency oscillations regarding the removal of DBO5 for the release of the effluent. As for the other analyses, inefficiency was verified in the treatment of most of the parameters, which demonstrates the operational failure of the ETE, with the need to adapt to meet the current normative legislation that regulates the release of treated effluent and the quality of the receiving watercourse. Debido al gran aumento de operaciones y producción, ha habido una alta producción de residuos en mataderos en los últimos años, pero cuando se desordenan y no se supervisan, el tratamiento de estos residuos puede tener impactos nocivos en el medio ambiente. De esta forma, el estudio hace una evaluación de una Estación de Tratamiento de Efluentes (ETE) existente de un matadero en São Luís - MA, analizando su composición química y comparándola con la Ordenanza SEMA Nº 79/2013 del estado de Maranhão, Resolución CONAMA N° 430/2011 y Resolución CONAMA N° 357/2005. Se observa que los valores del matadero en mención son cercanos a los estipulados por la CETESB, siendo algunos relativamente inferiores, como: aceites y grasas y sólidos en suspensión. Sin embargo, se pudo verificar que la ETE tiene oscilaciones de eficiencia en cuanto a la remoción de DBO5 para la liberación del efluente. En cuanto a los demás análisis, se verificó ineficiencia en el tratamiento de la mayoría de los parámetros, lo que demuestra la falla operativa de la ETE, con la necesidad de adecuarse para cumplir con la legislación normativa vigente que regula la descarga de efluentes tratados y la calidad de los mismos corrientes de agua receptores. Devido ao grande aumento de operações e produções, houve uma alta produção de resíduos em abatedouros e frigoríficos nos últimos anos, porém quando desordenado e não fiscalizado, o tratamento desses resíduos pode acarretar impactos nocivos ao meio ambiente. Dessa forma, o objetivo do estudo foi avaliar o efluente de uma Estação de Tratamento de Efluentes (ETE) de um abatedouro frigorífico em São Luís – MA, quanto a sua composição físico-química e os parâmetros de atendimento da CETESB (2008), Portaria SEMA Nº 79/2013 do estado do Maranhão, Resolução CONAMA Nº 430/2011 e Resolução CONAMA Nº 357/2005. Observa-se que os valores do efluente do abatedouro em questão estão próximos aos estipulados pela CETESB, alguns sendo relativamente menores, tais como: óleos e graxas e sólidos suspensos. No entanto, foi possível verificar que a ETE possui oscilações de eficiência no que se refere à remoção de DBO5 para o lançamento do efluente. Quanto às demais análises, foi verificada ineficiência no tratamento de boa parte dos parâmetros, o que demonstra falha operacional da ETE, havendo a necessidade de adequação para atender às legislações normativas vigentes que regulam o lançamento de efluente tratado e qualidade dos corpos hídricos receptores.
- Published
- 2022
13. Comparação entre o método calorimétrico e titulométrico na determinação da DQO através de análises efetuadas em esgoto doméstico e efluentes industriais
- Author
-
Rodrigo de Freitas Bueno
- Subjects
dqo ,colorimetria ,titulometria ,esgoto domestico ,efluente industrial ,Environmental technology. Sanitary engineering ,TD1-1066 ,Environmental engineering ,TA170-171 ,Environmental sciences ,GE1-350 - Abstract
Objetiva-se, aqui, a comparação dos resultados de testes laboratoriais dos métodos calorimétrico e titulométrico para determinação da DQO em esgoto doméstico e efluentes industriais, onde, atualmente há uma grande desconfiança em relação aos resultados obtidos pela análise colorimétrica quando comparado à titulométrica. O estudo apresenta, ainda, um levantamento de custo da análise e uma discussão crítica da questão ambiental dos resíduos gerados em ambos os métodos. Os valores de DQO obtidos com a metodologia calorimétrica não foram significativamente diferentes quando comparados com o método titulométrico. Não foi observado nenhum padrão ou regularidade nas diferenças, ou seja, não se pode dizer que a DQO obtida pelo método titulométrico é sempre maior do que aquela obtida pelo método calorimétrico ou vice-versa.
- Published
- 2009
- Full Text
- View/download PDF
14. Tratamiento de efluentes de la fabricación de lente de sol
- Author
-
Forti, Juliane C., Tadayozzi, Yasmin S., Silva, Tamara Cardeal C. da, Andrade, Carolina R. V. de, and Santos, Felipe A. dos
- Subjects
Processo oxidativo avançado ,Industrial effluent ,Advanced oxidative process ,Electro-Fenton ,Eletro-Fenton ,Efluente industrial ,Anthraquinone ,Antraquinona ,Tintes ,Proceso oxidativo avanzado ,Corantes ,Dyes - Abstract
This work is a partnership with an ophthalmic products company that generates effluents containing a mixture of three dyes: blue 56, yellow 54 and red 60, all in the anthraquinone class. Dyes in this class are resistant to degradation due to their aromatic structure, which retains color for long periods of time. The treatment of these dyes is extremely important due to their toxicity, and may present carcinogenic and mutagenic behavior. The objective of this work was to oxidize polluting organic compounds using advanced oxidative processes. For this, constant current electrolysis was performed using oxide electrodes as heterogeneous catalysts together with Fenton's reagent (Fe2+ + H2O2). Discoloration and oxidation were monitored by UV-Visible spectrometry, high performance liquid chromatography and total organic carbon. The applied treatment allowed a rapid degradation of the chromophore groups and there was a great influence of the hydrogen peroxide concentration on the speed of this degradation. The results were satisfactory, since the coloration was eliminated and the oxidation products identified do not present toxicity and can be easily treated by traditional methods. Este trabajo es una asociación con una empresa de productos oftálmicos que genera efluentes que contienen una mezcla de tres tintes: azul 56, amarillo 54 y rojo 60, todos en la clase de antraquinonas. Los tintes de esta clase son resistentes a la degradación debido a su estructura aromática, que retiene el color durante largos períodos de tiempo. El tratamiento de estos colorantes es de suma importancia por su toxicidad, pudiendo presentar un comportamiento cancerígeno y mutagénico. El objetivo de este trabajo fue oxidar compuestos orgánicos contaminantes mediante procesos oxidativos avanzados. Para ello, se realizó una electrólisis en corriente constante utilizando electrodos de óxido como catalizadores heterogéneos junto con el reactivo de Fenton (Fe2+ + H2O2). La decoloración y oxidación se controlaron mediante espectrometría UV-visible, cromatografía líquida de alta resolución y carbono orgánico total. El tratamiento aplicado permitió una rápida degradación de los grupos cromóforos y hubo una gran influencia de la concentración de peróxido de hidrógeno en la velocidad de esta degradación. Los resultados fueron satisfactorios, ya que se eliminó la coloración y los productos de oxidación identificados no presentan toxicidad y pueden tratarse fácilmente por métodos tradicionales. Este trabalho é uma parceria com uma empresa de produtos oftálmicos que gera efluentes contendo uma mistura de três corantes dispersos: azul 56, amarelo 54 e vermelho 60, todos da classe das antraquinonas. Os corantes dessa classe são resistentes a degradação devido a sua estrutura aromática, a qual retêm a cor por longos períodos de tempo. O tratamento destes corantes é de extrema importância devido à sua toxicidade, podendo apresentar comportamento cancerígeno e mutagênico. O objetivo deste trabalho foi oxidar os compostos orgânicos poluentes usando processos oxidativos avançados. Para isso, foram realizadas eletrólises a corrente constante usando eletrodos de óxidos como catalisadores heterogêneos juntamente com o reagente de Fenton (Fe2+ + H2O2). A descoloração e oxidação foram monitoradas por espectrometria UV-Visível, cromatografia líquida de alta eficiência e carbono orgânico total. O tratamento aplicado permitiu uma rápida degradação dos grupos cromóforos e houve grande influência da concentração do peróxido de hidrogênio na velocidade dessa degradação. Os resultados foram satisfatórios, uma vez que a coloração foi eliminada e os produtos da oxidação identificados não apresentam toxicidade e podem facilmente tratados por métodos tradicionais.
- Published
- 2021
15. Avaliação e identificação de toxicidade em efluente da fabricação de resinas de poliester
- Author
-
Caffaro-Filho, Roberto Augusto, 1977, Durrant, Lúcia Regina, 1957, Morita, Dione Mari, Umbuzeiro, Gisela de Aragão, Nour, Edson Aparecido Abdul, Guimarães, José Roberto, Alegre, Ranulfo Monte, Universidade Estadual de Campinas. Faculdade de Engenharia de Alimentos, Programa de Pós-Graduação em Ciência de Alimentos, and UNIVERSIDADE ESTADUAL DE CAMPINAS
- Subjects
Industrial wastewater ,Polyester resin ,Efluente industrial ,Alfa, Beta-aldeidos insaturados ,Alfa,Beta-unsaturated aldehydes ,Resina de poliester ,Bioensaios ,Bioassays - Abstract
Orientador: Lucia Regina Durrant Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos Resumo: Os processos industriais são geradores de uma ampla variedade de contaminantes que estão presentes nas águas residuarias. A seleção de processos de tratamento baseia-se nas características do efluente a ser tratado. Neste trabalho investigou-se um efluente tóxico da fabricação de resinas de poliéster. Existem poucas informações na literatura sobre este tipo de água residuaria. Procedeu-se a caracterização do efluente, efetuando-se a avaliação e identificação de constituintes tóxicos presentes no mesmo por meio de uma abordagem orientada por toxicidade. Foi utilizado bioensaio respirometrico em lodo ativado para avaliar a toxicidade do efluente bruto. Então, foram efetuados tratamentos físicos e químicos para fracionamento do efluente, e apos cada um deles, realizou-se o mesmo bioensaio. Dessa maneira, avaliou-se qual técnica de fracionamento foi a mais efetiva na redução da toxicidade. A maior redução de toxicidade foi observada apos o fracionamento do efluente por arraste com ar em pH 11 (62,5 %). Este resultado demonstrou que uma fração significativa da toxicidade do efluente para lodos ativados era causada por compostos orgânicos volatilizados em pH 11. Isso indica que o tratamento do efluente por arraste com ar em pH básico pode ter impacto positivo em um tratamento biológico aeróbio subseqüente. Uma vez determinado o tipo de compostos no efluente que provocam efeitos tóxicos (Compostos Organicos Volateis - COVs), procedeu-se a esforços analíticos visando a identificação dos mesmos. Analises por headspace do efluente por cromatografia gasosa e espectrometria de massa identificaram a presença de aldeidos insaturados (congeneres de acroleina). Tais compostos tinham relacao direta com o efeito tóxico observado. Foram também realizados bioensaios utilizando microrganismos anaerobios. Para tanto, mediu-se o volume de gas produzido por uma biomassa anaerobia em contato com o efluente bruto e com o efluente fracionado por arraste com ar em pH 11. Não se observou redução na toxicidade do efluente mesmo com este fracionamento. Comparando-se esses resultados aos obtidos com lodo ativados, foi verificado que os compostos removidos por arraste com ar em pH 11 não apresentaram o mesmo grau de toxicidade para esta biomassa anaerobia. Tais resultados indicam que a utilização de processo de tratamento biológico anaerobio seria uma opção adequada para a condução de futuros estudos de tratabilidade deste efluente. Os resultados obtidos neste trabalho de avaliação e identificação de toxicidade em efluente da fabricação de resinas de poliéster ratificam a abordagem utilizada como uma valorosa ferramenta na caracterização de efluentes industriais tóxicos, principalmente nos casos onde não se encontram disponíveis informações especificas relacionadas ao efluente estudado Abstract: Industrial processes generate a vast range of contaminants that are present in wastewaters. Treatment process selection is based on wastewater characteristics. In this work a toxic polyester resin manufacturing wastewater was investigated. Specific literature on this kind of wastewater is rare. The characterization of this wastewater was conducted, evaluating and identifying toxicity by applying a toxicity-oriented approach. An activated sludge respirometric bioassay was used to assess effluent toxicity. Then, physical and chemical treatments were performed for effluent fractionation. After each fractionation, the same bioassay was conducted. In this way, it was assessed which fractionation technique was the most effective in reducing effluent toxicity. The greater toxicity reduction was observed after effluent fractionation with air stripping in pH 11 (62.5 %). This result showed that a significant fraction of wastewater toxicity for activated sludge was caused by organic compounds volatilized in pH 11. This indicates that effluent treatment by air stripping in basic pH could have a positive impact in a conjugated aerobic biological treatment. Once the type of compounds causing wastewater toxicity has been determined (Volatile Organic Compounds ¿ VOCs), analytical efforts aiming the identification of these compounds were made. Wastewater headspace gas chromatographic analyses coupled with mass spectrometry identificated the presence of a,ß-unsaturated aldehydes (acrolein congeners). These compounds were directly related to the observed toxic effect. Bioassays using anaerobic microorganisms were also conducted. To that purpose, the volume of gas produced by an anaerobic biomass in contact with the baseline effluent and with the fractionated effluent by air stripping in pH 11 was measured. No toxicity reduction was observed with this fractionation. By comparing this result with the one obtained with the respirometric bioassay, it was found that the compounds removed by air stripping in pH 11 did not inhibit this kind of biomass in the same degree which they inhibited activated sludge. This indicates that the use of an anaerobic treatment process would be an adequate option for conducting future treatability studies in this wastewater. The results obtained in this research of toxicity identification evaluation of a polyester resin manufacturing effluent confirm that the toxicity-oriented approach is a valuable tool for the characterization of toxic industrial wastewaters, especially in cases when specific information related to the studied wastewater is lacking Doutorado Doutor em Ciência de Alimentos
- Published
- 2021
16. Águas de processo da REPLAN
- Author
-
Gasparini, Mirthys Cozzett, Guimarães, José Roberto, 1958, Mendes, Carlos Gomes da Nave, 1958, Ferreira, Milena Guedes Maniero, Dezotti, Márcia, Universidade Estadual de Campinas. Faculdade de Engenharia Civil, Arquitetura e Urbanismo, Programa de Pós-Graduação em Engenharia Civil, and UNIVERSIDADE ESTADUAL DE CAMPINAS
- Subjects
Industrial effluent ,Processo oxidativo avançado ,Efluente industrial ,Petroleum refinery ,Água - Reuso ,Water - Reuse ,Advanced oxidation processes (AOPs) ,Petróleo - Refinarias - Abstract
Orientadores: José Roberto Guimarães, Carlos Gomes da Nave Mendes Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo Resumo: No presente trabalho foi realizada a caracterização de várias correntes de águas de processo da REPLAN (Refinaria de Paulínia), bem como a avaliação dos processos de fotólise (UV), peroxidação (H2O2), peroxidação assistida por radiação ultravioleta (H2O2/UV), reagente de Fenton (H2O2/Fe2+) e foto-Fenton (H2O2/Fe2+/UV) no tratamento de um dos efluentes, principalmente na degradação dos compostos orgânicos. Analisando-se os dados de caracterização dos diferentes efluentes foi possível sugerir alternativas de reuso no processo de refino, como também selecionar a corrente de água ácida retificada para aplicação dos processos físico-químicos de tratamento. A eficiência dos ensaios de tratabilidade foi baseada na redução da concentração do carbono orgânico dissolvido (COD). Dentre os processos estudados, os processos oxidativos avançados (POA) H2O2/UV e foto-Fenton apresentaram 95 % de eficiência após 150 minutos de ensaio. As condições ótimas foram obtidas na relação mássica COD: H2O2 de 1:7 para o processo peroxidação assistida por radiação UV, e de 1:5 e concentração de Fe2+ de 31 mg/L para o processo foto-Fenton. O efluente tratado pelo processo H2O2/UV poderia ser reutilizado como água de reposição no sistema de resfriamento, já que esta é responsável por 49 % do total de água utilizada na refinaria Abstract: In the present study was performed the characterization of various process water from REPLAN (Paulínia Refinery) as well as an assessment of 5 processes to treat one of the effluents: photolysis (UV), peroxidation (H2O2), peroxidation assisted by ultraviolet radiation (H2O2/UV), Fenton reagent (H2O2/Fe2+) and photo-Fenton (H2O2/Fe2+/UV), in order to degrade the organic compounds. Effluents characterization results provided reuse possibilities in the process refining and also selected the stripped sour water stream for application of physical-chemical treatments. The processes efficiency was evaluated by the dissolved organic carbon (DOC) reduction. Among the processes studied, the advanced oxidation processes (AOPs) H2O2/UV and photo-Fenton reached 95 % efficiency after 150 minutes of reaction. The optimum conditions were obtained in a mass ratio COD: H2O2 of 1:7 for peroxidation assisted by UV radiation, and of 1:5 with 31 mg/L of Fe2+ for photo-Fenton. The effluent treated by AOP H2O2/UV could be reused as make-up water in cooling systems, since it is responsible for 49 % of the total water used in the refinery Mestrado Saneamento e Ambiente Mestre em Engenharia Civil
- Published
- 2021
17. TRATAMIENTO DE AGUAS RESIDUALES DE UNA INDUSTRIA PROCESADORA DE PESCADO EN REACTORES ANAERÓBICOS DISCONTINUOS.
- Author
-
Marín Leal, Julio César, Chinga Panta, Carlos Aníbal, Velásquez Ferrín, Abrahan Isaac, González Cabo, Pierre Andrés, and Zambrano Rodríguez, Luz María
- Abstract
Copyright of Ciencia e Ingenieria Neogranadina is the property of Ciencia e Ingenieria Neogranadina and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2015
- Full Text
- View/download PDF
18. Characterização do Floco Biológico e da Microfauna em Sistema de Lodos Ativados.
- Author
-
Soares, Juliana Ferreira, Ilha, Róbson, de Vasconcellos, Noeli Júlia Schüssler, and Santiago, Mariana Ribeiro
- Abstract
The microscopic investigation of the floc and the microfauna present in the sludge is an important indicator of the performance and efficiency of the activated sludge system. Given this importance, the study aimed to characterize the structure of the biological flocs and identify the organisms that make up the microfauna in the aeration tanks from the industrial WWTP, relating to the physico-chemical parameters and process efficiency. For the characterization of floc and microfauna qualitative microscopic technique was employed. The physical-chemical parameters were supplied by industry's own laboratory. During the study were observed groups of testate amoebae, rotifers, attached ciliates and ciliates free natantes characterizing the process with good purification and as the structure of the flocs between ideal and filamentous bulking. Qualitative analysis of biological floc structure proved important for the identification of cases of the filamentous bulking. [ABSTRACT FROM AUTHOR]
- Published
- 2014
- Full Text
- View/download PDF
19. Aplicación de la semilla de moringa (Moringa oleífera) como coagulante natural en el tratamiento del efluente de una industria de tintas en Ceará
- Author
-
Santana, Giuliana Buzelli, Nóbrega, Diana Colares, Oliveira, Juliene Tomé, Martins, Igor Alves, Nascimento, Ronaldo Ferreira do, and Vidal, Carla Bastos
- Subjects
Moringa oleífera ,Adsorção ,Coagulante natural ,Efluente industrial ,Coagulação ,Planejamento fatorial ,Tratamento de efluentes - Abstract
The wastewater from textile plants and ink factories has fostered a great interest in the scientific community for being the greatest water and chemicals consumers in their processes. The continuous use of chemical coagulants for treating both water and wastewater has caused impacts not only to the environment but also to the general public health. Consequently, less damaging alternatives, such as the use of vegetal or mineral coagulants, have been studied to deal with this problematic. The seed from the Moringa oleífera plant, besides being able to be used as a coagulant in water treatment, can also serve as an adsorbent in the coagulation-flocculation treatment from industrial wastewater as a means of removing various classes of pollutants. This research aimed to evaluate the performance and the feasibility of the application of the Moringa oleífera seed as a coagulant-flocculent in the ink producing industry effluent treatment. To conduct the experiments, the industrial effluent was collected directly from the industry reservoir and used without any pre-treatment. To optimize the variables that influence the treatment efficiency the experimental planning was used as a tool. Three factors have been varied: pH, coagulant mass and agitation speed during the flocculation step. To analyze the significance of each effect, Pareto charts were generated. According to the statistical program utilized, the optimal operating conditions, which minimize the values of color and TOC (total organic carbon) was pH 3; agitation 3 and Moringa concentration of 15g/L. For the conductivity and turbidity parameters, the optimal operating conditions were pH 9, agitation 7 and Moringa concentration of 5g/L. However, the statistically significant factors were pH 9 for the conductivity parameter and the coagulant concentration factor of 15g/L for turbidity. In terms of removal efficiency, it has been observed that for all experiments the efficiency of removal of color and turbidity was above 97%. As for the TOC removal efficiency, it varied from 32 to 46%. It was possible to conclude that the Moringa seed was an efficient and clarification agent of high complexity wastewater, making it a sustainable and economically viable alternative due to its easy cultivation in tropical and arid areas. As águas residuais de plantas têxteis e fabricação de tinta têm despertado grande interesse na comunidade científica por serem os maiores consumidores de água e produtos químicos em seus processos. O uso contínuo de coagulantes químicos no tratamento dessas águas e efluentes tem causado impacto não só ao meio ambiente em geral, como também à saúde pública. Diante dessa problemática, tem-se estudado alternativas menos agressivas, como o emprego de coagulantes de origem vegetal ou mineral. A semente de Moringa oleífera, além de poder ser utilizada como coagulante no tratamento de águas, também exerce propriedades adsortivas no tratamento de coagulação-floculação de águas industriais, aumentando, assim, o poder de remoção de diversas classes de poluentes. A presente pesquisa teve como objetivo avaliar o desempenho e viabilidade da aplicação da semente de Moringa oleífera como agente coagulador-floculador no tratamento do efluente de uma indústria de tintas. Para a realização dos experimentos, o efluente industrial foi coletado diretamente do reservatório da fábrica e utilizado sem pré-tratamento. Para aperfeiçoar as variáveis que atuam na eficiência do tratamento, foi utilizado como ferramenta o planejamento experimental. Foram variados três fatores: pH, massa do coagulante e velocidade de agitação da etapa de floculação e, para analisar a significância de cada efeito, foram gerados os diagramas de Pareto. De acordo com o programa estatístico utilizado, as condições ótimas de operação, as quais minimizam os valores de cor e COT (Carbono Orgânico Total), foram: pH 3; agitação 3 e concentração de moringa de 15 g/L. Para os parâmetros condutividade e turbidez, as condições ótimas de operação, as quais minimizam os valores de cor e COT, foram: pH 9; agitação 7 e concentração de moringa de 5 g/L. Entretanto os fatores estatisticamente significativos foram o pH 9 para o parâmetro condutividade e o fator de concentração do coagulante de 15 g/L para o parâmetro turbidez. Em termos de eficiência de remoção, observou-se que, para todos os experimentos, a eficiência de remoção de cor e turbidez ficou acima de 97%. Já a eficiência de remoção de COT nos diferentes testes variou de 32 a 46%. Foi possível concluir que a semente de Moringa oleífera foi eficiente como agente clarificador de efluentes de alta complexidade, sendo uma alternativa sustentável e economicamente viável devido à facilidade de seu cultivo em regiões áridas e tropicais. Las aguas residuales de plantas textiles y fabricación de tinta despierta gran interés en la comunidad científica porque son los mayores consumidores de agua y productos químicos en sus procesos. El uso continúo de coagulantes químicos en el tratamiento de este agua y efluentes está causando impactos no solo al medio ambiente en general, pero a la salud pública que, ante esta problemática, se está estudiando alternativas menos agresivas, como el empleo de coagulantes de origen vegetal o mineral. La semilla de Moringa oleífera, además de poder ser utilizada como coagulante en el tratamiento de aguas, también ejerce propiedades de adsorción en el tratamiento de coagulación-floculación de aguas industriales, aumentando, así, el poder de remoción de diversas clases de contaminantes. Esta investigación tuvo el objetivo de evaluar el rendimiento y viabilidad de la aplicación de la semilla de Moringa oleífera como agente coagulador-floculador en el tratamiento de efluente de una industria de tintas. Para la realización de los experimentos, el efluente industrial fue colectado directamente del embalse del taller y utilizado sin tratamiento anticipado. Para optimizar las variables que actúan en la eficiencia del tratamiento, se utilizó como herramienta la planificación experimental. Fueron variados tres factores: pH, masa del coagulante y velocidad de agitación de la fase de floculación. Para analizar la significancia de cada efecto fueron generados gráficos de Pareto. De acuerdo con el programa estadístico utilizado, las condiciones optimas de operación, las cuales minimizan los valores de color Y COT (Carbono Orgánico Total) fueron: pH 3; agitación 3 y concentración de moringa 15g/L. Para los parámetros de conductibilidad y turbidez, las condiciones optimas de operación, las cuales minimizan los valores de color y COT, fueron: pH 9; agitación 7 y concentración de moringa 5g/L. Sin embargo, los factores que fueron estadísticamente significativos fueron Ph 9 para el parámetro de conductibilidad y el factor concentración del coagulante 15g/L para el parámetro turbidez. En cuestiones de eficiencia de remoción, se observo que para todos los experimentos, la eficiencia de remoción de color y turbidez quedó más de 97%. Ya la eficiencia de remoción de COT en los distintos testes fluctuó de 32 a 46%. Fue posible concluir que la semilla de Moringa fue eficiente como agente clarificador de efluentes de alta complejidad, tornándola una alternativa sostenible y económicamente viable debido a facilidad de su cultura en regiones áridas y tropicales. Les eaux usées des usines textiles et de la fabrication de peintures ont suscité un grand intérêt dans la communauté scientifique, car ce sont les plus gros consommateurs d’eau et de produits chimiques pendant leurs processus. L’utilisation continue de coagulants chimiques dans le traitement de ces eaux et effluents a eu des effets non seulement sur l’environnement en général, mais aussi sur la santé publique. Devant ce problème, des alternatives moins agressives ont été étudiées, telles que l’utilisation de coagulants d’origine végétal ou minéral. En plus de pouvoir être utilisée comme coagulant dans le traitement de l’eau, la semence de Moringa à huile a également des propriétés d’absorption dans le traitement de coagulation-floculation des eaux industrielles, ce qui fait augmenter le pouvoir d’élimination de plusieurs classes de polluants. L’objectif de la présente recherche a été d’évaluer la performance et la viabilité de l’application de la semence de Moringa à huile comme agent coagulateur-floculant dans le traitement des effluents d’une industrie de peinture. Pour les expériences, l’effluent industriel a été collecté directement du réservoir de l’usine et utilisé sans prétraitement. Pour optimiser les variables qui agissent sur l’efficacité du traitement, le plan expérimental a été utilisé comme outil.Trois facteurs variaient : le pH, la masse coagulante et la vitesse d’agitation de l’étape de floculation. Pour analyser la signification de chaque effet, des diagrammes de Pareto ont été générés. Selon le programme statistique utilisé, les conditions optimales de fonctionnement, qui minimisent la couleur et les valeurs de COT (Carbone Organique Total) étaient : pH 3 ; agitation 3 et concentration de moringa 15 g / L. Pour les paramètres de conductivité et de turbidité, les conditions optimales de fonctionnement, qui minimisent la couleur et les valeurs de COT, étaient : pH 9 ; agitation 7 et concentration de moringa 5 g / L. Néanmoins, les facteurs statistiquement significatifs ont été le pH 9 pour le paramètre de conductivité et le facteur de concentration de coagulant 15 g / L pour le paramètre de turbidité. En ce qui concerne d’efficacité de suppression, il a été observé que pour toutes les expériences, l’efficacité de suppression de la couleur et de la turbidité a été supérieure à 97%. L’efficacité de suppression du COT dans les différents tests a varié de 32 à 46%. Il a été possible de conclure que la semence de Moringa a été efficace comme agent clarifiant des effluents de haute complexité, ce qui en fait une alternative durable et économiquement viable en raison de sa culture facile dans les régions arides et tropicales.
- Published
- 2020
20. Processo UV/H2 O2 aplicado como pós-tratamento de águas residuárias da indústria de papel e celulose
- Author
-
Jean Carlo Salomé dos Santos Menezes, Cristiane Lisboa Giroletti, María Ángeles Lobo-Recio, Flávio Rubens Lapolli, and Maria Eliza Nagel-Hassemer
- Subjects
lcsh:GE1-350 ,papel e celulose ,Chemistry ,radiação uv ,General Medicine ,lcsh:Environmental technology. Sanitary engineering ,lcsh:TA170-171 ,efluente industrial ,processo oxidativo avançado ,lcsh:TD1-1066 ,lcsh:Environmental sciences ,lcsh:Environmental engineering - Abstract
Desafios econômicos e ecológicos procedentes da crise hídrica e das restrições impostas pela legislação ambiental contribuíram recentemente para a expansão das aplicações dos processos oxidativos avançados como técnicas alternativas de tratamento de efluentes. O presente trabalho objetivou avaliar o processo UV/H2 O2 aplicado como pós-tratamento de águas residuárias da indústria de papel e celulose, sob diferentes concentrações de oxidante. Os resultados revelaram o potencial da aplicação do processo UV/ H2 O2 na oxidação de substâncias orgânicas com remoção da DBO5 de 85 a 92%. A remoção da cor foi total para todas as concentrações de H2 O2 . Para a turbidez, os índices de remoção variaram entre 41 e 83%. Na remoção dos compostos aromáticos, o processo reduziu em até 98% a aromaticidade do efluente, mostrando assim a efetividade do processo no tratamento dos efluentes da indústria de papel e celulose.
- Published
- 2018
21. Flutuação das características químicas do efluente industrial de fecularia de mandioca - DOI: 10.4025/actasciagron.v25i1.2601
- Author
-
Frederico Fonseca da Silva, Paulo Sergio Lourenço de Freitas, Altair Bertonha, Roberto Rezende, Antônio Carlos Andrade Gonçalves, and Rivanildo Dallacort
- Subjects
composição química ,efluente bruto ,efluente industrial ,Agriculture (General) ,S1-972 - Abstract
O presente trabalho foi realizado no município de São Mateus (ES) e teve como objetivo avaliar as concentrações de elementos e compostos químicos no efluente industrial de uma fecularia de mandioca, a partir de amostras obtidas em alguns pontos definidos entre a saída da indústria e o reservatório final, em diferentes momentos. A metodologia consistiu em coletar, semestralmente, uma amostra, de forma a obter uma medida na estação da seca e outra na estação das chuvas, em 6 diferentes pontos, ao longo do trecho citado. Adotou-se, como testemunha, a água captada no Rio São Mateus, de classe C1S1, a qual tem sido usada na indústria, como parte do processo de beneficiamento e de transformação da raiz em fécula. Observou-se que os valores das variáveis medidas foram alterados em função do tempo e da posição no espaço. Essa variação foi influenciada pela temperatura do ar, radiação solar e profundidade da coleta.
- Published
- 2008
- Full Text
- View/download PDF
22. Características de la biopelícula de un reactor RBC en presencia y ausencia de metales pesados
- Author
-
Marín Leal, Julio César, Fernández Castillo, Karelia, Behling de Calmón, Elisabeth, Carrasquero Ferrer, Sedolfo, Angulo, Nancy, Marín Leal, Julio César, Fernández Castillo, Karelia, Behling de Calmón, Elisabeth, Carrasquero Ferrer, Sedolfo, and Angulo, Nancy
- Abstract
Los efluentes industriales que contienen metales pesados causan efectos tóxicos sobre los ecosistemas naturales receptores, así como problemas de eficiencia en las plantas de tratamiento biológico. En el presente trabajo se compararon las características de la biopelícula de un reactor RBC de tres cámaras, en presencia y ausencia de metales pesados (Cd 5 mg/L y Cr 20 mg/L), bajo condiciones aeróbicas-mesofílicas y escala de laboratorio. La biopelícula se formó a partir de un lodo aerobio obtenido de una planta de tratamiento de aguas residuales de la localidad. El reactor se alimentó con un efluente industrial sintético a flujo continuo, con una carga orgánica de 5,81 gDQO/d.m2. En el efluente final de cada cámara se monitorearon los parámetros fisicoquímicos: pH, alcalinidad total, oxígeno disuelto, potencial redox, demanda química de oxígeno (DQO), sólidos suspendidos totales, sólidos suspendidos volátiles, concentración de Cd y Cr. La evolución de la biopelícula fue registrada fotográficamente y también se determinaron: grosor, índice de biomasa, conteo de heterótrofos y caracterización de los principales grupos bacterianos. El contenido de materia orgánica (DQO) en el efluente tratado fue significativamente menor (18,0 %) en ausencia de metales, mientras que las remociones de Cd y Cr se ubicaron en 96,7±0,2 y 57,2±1,3 %, respectivamente. Las concentraciones finales de Cr no cumplieron con el límite de descarga establecido en la normativa nacional (2,0 mg/L). La biopelícula presentó menor grosor y abundancia de heterótrofos en presencia de los metales, como consecuencia del efecto tóxico de los mismos. Las bacterias más abundantes durante el tratamiento del efluente pertenecieron a los géneros: Paenibacillus, Bacillus y Lysinibacillus.
- Published
- 2019
23. Anaerobic Cynamon filter adapted for wastewater treatment of the dairy industry
- Author
-
SOUSA, Weberton Dantas de., OLIVEIRA, Andréa Maria Brandão Mendes de., MARACAJÁ, Patrício Borges., and FONSECA, Paulo Henrique da.
- Subjects
Engenharia Sanitária ,Effluents - Biological treatment ,Industrial effluent ,Sustainability ,Efluente industrial ,Sustentabilidade ,Indústria láctea ,Dairy industry ,Efluentes - Tratamento biológico - Abstract
Submitted by JOELMA NASCIMENTO (joelma_goldmann@hotmail.com) on 2019-09-19T11:35:18Z No. of bitstreams: 1 WEBERTON DANTAS DE SOUSA - DISSERTAÇÃO - PPGSA - ACADÊMICO - 2019.pdf: 1105513 bytes, checksum: c4d5a27d92177ef4b86b66987e74f1e0 (MD5) Made available in DSpace on 2019-09-19T11:35:18Z (GMT). No. of bitstreams: 1 WEBERTON DANTAS DE SOUSA - DISSERTAÇÃO - PPGSA - ACADÊMICO - 2019.pdf: 1105513 bytes, checksum: c4d5a27d92177ef4b86b66987e74f1e0 (MD5) Previous issue date: 2019-07-03 A indústria de laticínios é uma das mais importantes do setor alimentício no país, e sua grandiosidade também se reflete nos problemas quanto aos resíduos por ela gerados. É essencial em uma sociedade cada vez mais preocupada com as questões ambientais, o uso de técnicas e procedimentos que venham tratar o efluente de suas atividades para garantir a qualidade ambiental. Utilizar meios eficientes e sustentáveis é necessário para atender as características do meio e, principalmente, das empresas de pequeno porte, que em sua maioria carecem de sistemas de tratamento adequado. Nessa perspectiva, os filtros anaeróbios se apresentam como uma das alternativas para o tratamento de efluente de laticínios, uma vez que vários estudos demonstram sua eficiência e o baixo custo de sua construção e manutenção. Uma variação na utilização deste filtro foi proposta por Cynamon em 1986, com uma série de três filtros em fluxos ascendente, descendente e ascendente, respectivamente. Este trabalho teve por objetivo testar filtros anaeróbios Cynamon para o tratamento de efluentes oriundos de laticínios. O esgoto bruto foi tratado em dois sistemas de filtros anaeróbios Cynamon, um, com fluxo igual ao proposto originalmente e o outro, com fluxos totalmente ascendentes. Os efluentes bruto e tratado foram submetidos a testes de sólidos sedimentáveis, sólidos totais, sólidos totais fixos, sólidos totais voláteis, pH, cor, turbidez, condutividade elétrica e Demanda Química de Oxigênio (DQO). Os resultados observados para os sólidos sedimentáveis estavam fora dos padrões estabelecidos pela legislação. Para os sólidos totais, seus resultados indicaram a necessidade de um pré-tratamento. Foi possível observar uma melhora nos teores quanto ao pH, cor, turbidez mesmo estes fora dos padrões estabelecidos em lei. Quanto a DQO, foi verificado um incremento entre a etapa inicial e final do tratamento. Dairy factories have a primordial role in the Brazilian food industry. However, its wastes cause severe ecological impacts. Techniques and procedures to treat effluents of dairy activities are essential to ensure environmental quality. Most small businesses lack proper waste treatment systems, needing implementation of efficient methods to meet environmental sustainability. Several studies show the efficiency and low cost of anaerobic filters as alternatives for the treatment of sewage. Cynamon proposed a variation on the use of this filter in 1986, with a series of three filters in ascending, descending, and ascending flows. This work aimed to test Cynamon anaerobic filters for the treatment of dairy effluents. Raw sewage was treated in two Cynamon anaerobic filter systems, one with the same flow as initially proposed and the other with fully ascending flows. Raw and treated effluents were analyzed for sedimentable solids, total solids, fixed solids, volatile solids, pH, color, turbidity, electrical conductivity, and chemical oxygen demand (COD). The experiment showed that sedimentable solids were outside standards set by legislation and total solids needed pretreatment. At the other hand, the pH, color, turbidity, even outside law standards, had an improvement in quality after filtration. The COD increased from the initial to final stages of treatment.
- Published
- 2019
24. Acute ecotoxicity on Daphnia magna to evaluate effluent samples of Kraft pulp mill treated by UV/H2O2 process
- Author
-
Micheletto, Joicy, Sampaio, Naiara Mariana Fiori Monteiro, Ruiz, Henrique Zavattieri, Martins, Lucia Regina Rocha, Liz, Marcus Vinicius de, and Freitas, Adriane Martins de
- Subjects
advanced oxidation process ,processos oxidativos avançados ,ecotoxicology bioassays ,bioensaio ecotoxicológico ,efluente industrial ,industrial effluent - Abstract
The pulp and paper industry is one of world’s largest water consumers, generating high volumes of effluents. The Kraft process produces effluents with high BOD, COD, suspended solids, lignin and a myriad of potentially toxic compounds, which require treatment before discharge into the aquatic environment. Advanced oxidation processes, such as UV/H2O2, have been applied as treatment alternatives because they can destroy many compounds before they mineralize. However, when the oxidation process is incomplete, occurs could be produced by products with high toxicity. This study evaluated the acute toxicity on Daphnia magna of two effluent samples of Kraft pulp mill (KE1 and KE2) treated by UV/H2O2 process. The effects of the pH variation and oxidant concentration on the removal of DOC, total UV-vis spectral area and apparent color were considered to adjust the experiments’ conditions with diluted effluent KE1. Both samples were treated at pH 4.0 and 70 mg L-1 of H2O2 for 40 min, achieving removals of up to 69.4% in apparent color, 73.7% of phenolic compounds and 68.9% of lignin compounds. When the reaction was applied in undiluted effluent samples, the acute toxicity for Daphnia magna decreased for KE1 after 780 min of treatment, whereas KE2 became four times more toxic. The data showed that although the treatment had been efficient considering physics and chemicals parameters, it is necessary follow the oxidative processes with ecotoxicological bioassays to guarantee their safety, since different effluents of the Kraft pulp mill could present different levels of organic compound mineralization. Resumo A indústria de papel e celulose está entre as que mais consome água no mundo, gerando grandes volumes de efluentes. O processo Kraft produz efluentes com elevada DBO, DQO, sólidos suspensos, teor de lignina e uma mistura complexa de compostos potencialmente tóxicos, os quais necessitam de tratamento para posterior descarte no meio ambiente. Os processos oxidativos avançados, dentre eles o processo UV/H2O2, têm sido aplicado como alternativa de tratamento pois é capaz de degradar os mais diversos compostos até sua mineralização. No entanto, quando o processo oxidativo é incompleto, podem ser formados produtos intermediários com elevada toxicidade. Este estudo avaliou a toxicidade aguda em Daphnia magna de duas amostras de efluente Kraft (KE1 e KE2) tratadas por processo UV/H2O2. Os efeitos da variação de pH e da concentração do oxidante sobre a redução de COT, área espectral UV-vis e cor aparente foram utilizados para ajustar as condições experimentais com a amostra KE1 diluida. Ambas as amostras foram tratadas em pH 4.0 e com 70 mg L-1 de H2O2 por 40 min, alcançando remoções de até 69,4% na cor aparente, 73,7% de compostos fenólicos e 68,9% de compostos lignínicos. Quando a reação foi aplicada nas amostras não diluídas de efluentes, a toxicidade aguda para Daphnia magna diminuiu para KE1 após 780 min de tratamento, enquanto KE2 tornou-se três vezes mais tóxica. Os dados mostraram que embora o tratamento tenha sido eficiente, considerando os parâmetros físicos e químicos, é necessário acompanhar os processos oxidativos por ensaios ecotoxicológicos para garantir sua segurança, uma vez que cada efluente kraft pode apresentar diferentes níveis de mineralização de seus compostos orgânicos.
- Published
- 2019
25. Reuso de água em indústria de fabricação de estruturas em concreto: uma estratégia de gestão ambiental
- Author
-
Jaros Odppes, Rafael, Teixeira Michalovicz, Diego, and Bilotta, Patrícia
- Subjects
Efluente industrial ,reuso de efluente ,cobrança pela água ,sustentabilidade empresarial ,Ciências ambientais - Abstract
In face of water crises registered in Brazil, the industrial reuse of water and treated effluent is an important instrument in the management of water resources, especially in large cities. The objective of this study was to analyze the opportunity to reduce the consumption of drinking water in concrete manufacturing industry, considering quantitative, qualitative and economic-financial requirements. The methodology used was based on: field surveys to determine the supply and demand of reuse water in the studied project; survey of required reuse water quality; proposal for treatment and evaluation of the necessary investment. The results showed a reduction of 61% in the monthly demand of drinking water of the analyzed enterprise, with a low investment (around R$ 3,000.00). It was concluded that the reuse of water may be considered a strategic alternative for the company, especially in a scenario of charging for the use of water and restriction in case of scarcity. Diante das frequentes crises hídricas registradas no Brasil, o reuso industrial de água e de efluente tratado é um importante instrumento na gestão dos recursos hídricos, sobretudo nas grandes cidades. O objetivo do trabalho foi analisar a oportunidade de redução do consumo de água potável em indústria de fabricação de estruturas em concreto, considerando requisitos quantitativos, qualitativos e econômico-financeiros. A metodologia utilizada baseou-se em: coletas de campo para determinar a oferta e a demanda de água de reuso no empreendimento estudado; levantamento da qualidade da água de reuso requerida; proposta de tratamento e avaliação do investimento necessário. Os resultados mostraram um potencial de redução de 61% da demanda mensal de água potável do empreendimento analisado, com um baixo investimento (cerca de R$ 3.000,00). Concluiu-se que o reuso de água pode ser considerado uma alternativa estratégica para a empresa, sobretudo em um cenário de cobrança pelo uso da água e de restrição em caso de escassez.
- Published
- 2018
- Full Text
- View/download PDF
26. ESTUDO FÍSICO-QUÍMICO E MICROBIOLÓGICO DA ÁGUA COM POTENCIAL REÚSO NÃO POTÁVEL EM INDÚSTRIA DE ALIMENTOS
- Author
-
Mônica Jachetti Maciel, Keli Hepp, Claudete Rempel, and Fernanda Aline Blatt Theves
- Subjects
Efluente industrial ,Meio ambiente ,Resíduos líquidos ,General Medicine - Abstract
O presente trabalho foi desenvolvido em uma indústria de alimentos do segmento de candies e teve como objetivo caracterizar as condições físico-químicas e microbiológicas da água de três linhas de produção para avaliar o potencial reúso para fins não potáveis, empregando-a na lavagem de maquinários, pisos, banheiros e na rega de jardins. A metodologia consistiu na medição do volume e vazão de água gerada no processo de limpeza em cada uma das linhas durante o processo produtivo. Foram coletadas amostras dos efluentes gerados durante as limpezas internas das máquinas, analisando a concentração de sólidos solúveis (ºBx), demanda química de oxigênio (DQO) e potencial hidrogeniônico (pH). Seis amostras foram encaminhadas para as seguintes análises microbiológicas: contagem total de bactérias mesófilas aeróbias, bolores e leveduras, Bacillus cereus, Escherichia coli, Salmonella spp. e Staphylococcus coagulase positiva. As três linhas de produção geram uma média de 5.968 litros de água/dia, DQO média de 60.809 mg L-1 e sólidos solúveis médio igual a 5,0 °Bx. Não houve crescimento microbiológico para contagem total de bactérias mesófilas aeróbias na primeira análise (00h00), mas 24 h depois, houve crescimento de 5 logs nas linhas um e três e na linha dois, 4 logs. Para bolores e leveduras, houve contaminação inicial com aumento de 2 logs na linha um, 4 logs na linha dois e 3 logs na linha três, 24 h após coleta. Conclui-se que essa água é viável para reúso não potável em um período inferior a 24 h após seu primeiro uso.
- Published
- 2018
- Full Text
- View/download PDF
27. Agregação de valor à resíduo agroindustrial: remoção de fenol utilizando adsorvente preparado a partir de casca de amendoim
- Author
-
Brígida Maria Villar da Gama, Marta Maria Menezes Bezerra Duarte, Thiago Silva, Graziele Elisandra do Nascimento, and C. M. B. M. Barbosa
- Subjects
010405 organic chemistry ,ativação física ,General Physics and Astronomy ,02 engineering and technology ,General Chemistry ,agroindustrial residue ,021001 nanoscience & nanotechnology ,physical activation ,efluente industrial ,01 natural sciences ,industrial effluent ,0104 chemical sciences ,General Materials Science ,0210 nano-technology ,resíduo agroindustrial - Abstract
RESUMO Este trabalho teve como objetivo avaliar a eficiência do carvão ativado com CO2 (CA) produzido a partir da casca de amendoim como adsorvente para remoção de fenol em solução aquosa (100-300 mg.L-1). A caracterização do CA foi realizada pelos métodos de BET, DRX, TGA, FT-IR e pHpcz, houve a caracterização da casca de amendoim (CS) para fins de comparação. Avaliou-se a influência do pH inicial da solução e a dosagem do adsorvente (D.A.). As condições de trabalho foram definidas com o auxílio de um planejamento fatorial 23 (PF) avaliando a influência das variáveis: D.A., granulometria (G.) e velocidade de agitação (V.A.) sobre o processo adsortivo, tendo como resposta a capacidade adsortiva q (mg.g-1). Com base nos resultados do PF foram realizados estudos cinéticos e de equilíbrio de adsorção. O carvão foi classificado como mesoporoso e predominantemente amorfo. Na TGA foi observada maior estabilidade do material após a ativação. Nos espectros de FT-IR foram identificadas bandas referentes a grupos hidroxilas, carboxílicos e ésteres. O pHpcz foi 10,4 possibilitando a utilização das soluções fenólicas em pH natural da solução. No PF, o maior q foi obtido para o nível 4 g.L-1, G. < 0,090 mm e 300 rpm, condição adotada nos estudos cinéticos e de equilíbrio. A evolução cinética foi rápida até 120 minutos, atingindo o equilíbrio em torno de 480 minutos. O modelo pseudo n ordem foi o que melhor se ajustou aos dados experimentais e foi constatado que o processo é controlado por mais de uma etapa, incluindo difusão intrapartícula. No estudo do equilíbrio os modelos que melhor se ajustaram aos dados experimentais foram os de Fritz-Schlunder e Redlich-Peterson apresentando qmax de 29,01 ± 0,96 mg.g-1. Os resultados demonstraram o potencial técnico do carvão em estudo para remoção de fenol presente em solução aquosa ABSTRACT This work had the aim of evaluate the efficiency of the activated carbon with CO2 (CA) produced from peanut shell as adsorbent which was applied to remove phenol from aqueous water (100-300 mg.L-1). The characterization of the CA was performed by BET, DRX, TGA, FT-IR e pHpcz methods and was performed the characterization of the peanut shell (CS) for comparison. The influence of initial pH of the solution and the dosage of the adsorbent (D.A.) was studied. Working conditions were defined with the help of a 23 factorial design (FD) evaluating the variables influence: DA, particle size (P.S) and stirring speed (S.S.) on the adsorption process, it is found as response the adsorption capacity, q (mg g-1). Based on the FD results kinetic studies and adsorption equilibrium were performed. The coal was classified as mesoporous and is predominantly amorphous. In the TGA greater stability of the material was observed after the activation. By FT-IR spectra bands were identified hydroxyl, carboxylic and ester groups. The pHpcz was 10.4 allowing the use of phenolic solutions in the natural pH of the solution. In FD the highest q was obtained for the level 4 g.L-1, G.
- Published
- 2018
28. Ammoniacal nitrogen adsorption of industrial effluent by zeolite Na-P1 synthesized from coal bottom ash
- Author
-
Sydney Sabedot, Alexandre Wasem, Ana Cristina Borba da Cunha, and Sabrine Cássia Bôer
- Subjects
zeólita Na-P1 ,Na-P1 zeolite ,adsorption ,General Physics and Astronomy ,nitrogênio amoniacal ,General Materials Science ,adsorção ,General Chemistry ,efluente industrial ,ammonia nitrogen ,industrial effluent - Abstract
A legislação ambiental em vigor impõe padrões de emissões cada vez mais restritivos às indústrias geradoras de efluentes. Considerando essas exigências, as empresas precisam se adequar a essas políticas, tornando seus processos produtivos mais eficazes e menos poluentes. A combustão de carvão mineral em usinas termoelétricas gera cinzas pesadas que retornam aos produtores do insumo mineral e constituem um passivo ambiental. Neste estudo, as cinzas pesadas foram utilizadas para testes na síntese hidrotérmica (Hidrogel), em meio alcalino, visando à formação de zeólita Na-P1. Para comprovar a sua efetiva formação, foram realizadas análises por difração de raios X, fluorescência de raios X e capacidade de troca catiônica com solução padrão de cloreto de amônio, cujo valor em termos de equivalentes foi de 23,7 mg g-1. Os resultados comprovaram a formação da zeólita Na-P1. Foram avaliados três efluentes industriais de três empresas distintas. A concentração final de nitrogênio amoniacal encontrada para os três efluentes após testes de adsorção de amônio em reator de leito fluidizado apresentaram uma redução de 49% ± 2 e os valores obtidos em termos de equivalentes foram de 21,8 mg g-1, 22,9 mg g-1 e 22,7 mg g-1. As Resoluções CONAMA 357/2005 430/2011 determinam padrões de qualidade de águas para diversas substâncias; no caso da amônia é de 20 mg L-1 de N/NH3. Considerando a grande dificuldade para reduzir os teores de nitrogênio amoniacal em determinados efluentes industriais, novas tecnologias vêm sendo implantadas, como a síntese de zeólitas a partir das cinzas pesadas de carvão. Esse estudo comprovou que a zeólita Na-P1 tem um grande potencial de adsorção para a redução de nitrogênio amoniacal de efluentes industriais. Environmental legislation in the country always requires more stringent standards for effluent generating industries. Companies must adapt to these laws making the industrial processes more efficient and less polluting. Burning coal in power plants produces bottom ash. This material returns to the coal producers and constitutes an environmental liability to the company. In this study, bottom ash was used in tests for the hydrothermal synthesis, under alkaline conditions, to generate zeolite Na-P1. Analyses by X-ray diffraction, X-ray fluorescence and cation exchange capacity with standard solution of ammonium chloride confirmed to the generation of zeolite Na-P1, and the value of the cation exchange capacity of the equivalent was 23.7 mg g-1. Three industrial effluents from three different companies were collected and evaluated. Tests for ammonia adsorption in a fluidized bed reactor were performed in the three effluents. The results for the final ammonia concentration showed a reduction of 49% ±2, and the values obtained are in terms of equivalent of 21.8 mg g-1, 22.9 mg g-1 e 22.7 mg g-1. CONAMA Resolution numbers 357/2005 and 430/2011 determining values for water quality standards to the various substances. The value for ammonia is 20 mg L-1N/NH3. Considering the difficulties to reduce the ammonia nitrogen concentration in certain industrial effluents, new technologies are being implemented, such as the synthesis of zeolite from coal bottom ash. This study showed that zeolite Na-P1 has good potential for adsorption to reduce the ammonia nitrogen content from industrial effluents.
- Published
- 2015
29. TRATAMIENTO DE AGUAS RESIDUALES DE UNA INDUSTRIA PROCESADORA DE PESCADO EN REACTORES ANAERÓBICOS DISCONTINUOS
- Author
-
Abrahan Isaac Velásquez Ferrín, Carlos Aníbal Chinga Panta, Julio César Marín Leal, Pierre Andrés González Cabo, and Luz María Zambrano Rodríguez
- Subjects
chemistry.chemical_classification ,Chemistry ,Science ,General Engineering ,Environmental engineering ,Alkalinity ,Pulp and paper industry ,efluente industrial ,Engineering (General). Civil engineering (General) ,materia biodegradable ,chemistry.chemical_compound ,reactores discontinuos ,Wastewater ,tratabilidad anaeróbica ,Organic matter ,Ammonium ,Nitrite ,TA1-2040 ,Effluent ,Kjeldahl method ,Total suspended solids ,lodo anaerobio - Abstract
En el presente trabajo se evaluó el tratamiento de las aguas residuales de una industria procesadora de pescado de la ciudad de Manta (Ecuador), en reactores anaeróbicos discontinuos, y se estableció su adecuación a las normas ambientales vigentes en materia de vertido. Para ello, se realizaron ensayos de laboratorio en reactores discontinuos de 1 L, con un tiempo de contacto de 24 h y provistos de un lodo anaerobio procedente de una planta de tratamiento de aguas residuales domésticas. Dicho efluente fue diluido con agua destilada en proporciones de 33%, 66% y 100%, correspondientes a las etapas I, II y III, respectivamente. Durante cada etapa se monitorearon los siguientes parámetros, de acuerdo con los métodos estándares: pH, alcalinidad total, DBO5.20, DQO, nitrito, amonio, nitrógeno total Kjeldahl (NTK), ortofostato, sulfato, sólidos suspendidos totales (SST) y sólidos suspendidos volátiles (SSV). Los resultados muestran porcentajes de remoción de materia orgánica, expresados como DBO5.20 (37.9±4.1%; 41.8±7.6% y 46.2±3.2%) y DQO (34.7±9.7%; 36.9±9.2% y 43.8±4.1%, para las etapas I, II y III, respectivamente), relativamente bajos como resultado del origen del inóculo usado, así como del contenido relativo de sales en el efluente industrial. Las remociones de amonio, NTK y ortofosfato estuvieron entre 60-95%, 25-37% y 6-25%, respectivamente. Bajo las condiciones de los ensayos realizados, el efluente tratado requiriere de la aplicación de un postratamiento para reducir el contenido de materia orgánica y nutrientes a los límites permisibles de descarga establecidos en la República de Ecuador.
- Published
- 2015
30. ANÁLISE DE REGRESSÃO NÃO LINEAR APLICADA A DADOS PROVENIENTES DO TRATAMENTO DE EFLUENTE DE INDÚSTRIA DE PAPEL E CELULOSE POR MEIO DE ULTRAFILTRAÇÃO E MICROFILTRAÇÃO.
- Author
-
Neves, Ludmila Carvalho, de Souza, Jeanette Beber, de Sousa Vidal, Carlos Magno, and Dias, Andrea Nogueira
- Abstract
Copyright of O Papel is the property of Associacao Brasileira Tecnica de Celulose e Papel and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2017
31. Biodegradación aeróbica de efluentes del procesamiento de pescado en reactores por carga
- Author
-
Marín, Julio César, Velásquez, Abrahan, Chinga, Carlos, Vizueta, Ever, Mero, Robert, Marín, Julio César, Velásquez, Abrahan, Chinga, Carlos, Vizueta, Ever, and Mero, Robert
- Abstract
Los efluentes originados durante el procesamiento de pescado y otros recursos marinos están caracterizados por una alta demanda bioquímica (DBO5,20) y química (DQO) de oxígeno, así como por niveles elevados de salinidad, sólidos, aceites y grasas, nitrógeno y fósforo, lo cual puede provocar un alto impacto sobre los ecosiste- mas receptores si no se realizan las operaciones de tratamiento requeridas. En este sentido, en el presente trabajo se evaluó la biodegradación aeróbica de efluentes resultantes del procesamiento de pescado de una industria de la ciudad de Manta (Ecuador), determinando la remoción del contenido orgánico y de nutrientes. Los ensayos de laboratorio se realizaron en reactores por carga en tres etapas, que in- cluyeron proporciones de efluente de 33, 66 y 100 % (etapas I, II y III, respectivamen- te). La caracterización fisicoquímica y microbiológica del efluente inicial y tratado se estableció en base a métodos estándares. Los resultados mostraron la alta capa- cidad del sistema aeróbico para la biodegradación de materia orgánica (85,4±3,4; 93,2±1,3 y 94,2±2,1% como DBO5,20 y de 82,0±5,3; 90,8±2,6 y 92,7±0,6% como DQO), amonio (45,3±4,6; 75,3±3,7 y 82,3±2,2%), nitrógeno total Kjeldahl (70,6±4,3; 81,6±2,3 y 83,2±2,3%), ortofosfato (24,1±5,2; 35,5±5,5 y 42,4±2,7%), así como de sólidos y bacterias coliformes, para las etapas I, II y III, respectivamente. El efluente trata- do cumplió con la norma ambiental ecuatoriana para la descarga a agua de mar y alcantarillado en cuanto al contenido de materia orgánica, pero requiriendo un postratamiento de desinfección para adecuar los niveles de bacterias coliformes.
- Published
- 2017
32. Biorreator de membranas de ultrafiltração aplicado ao tratamento de efluente industrial: avaliação da eficiência de tratamento e potencial de reúso da água
- Author
-
Farias, Amanda Paiva, Athayde Júnior, Gilson Barbosa, and Lattes não recuperado em 19/06/2019
- Subjects
Industrial effluent ,Efluente industrial ,Membrane bioreactor ,Ultrafiltration ,Ultrafiltração ,Reúso ,Reuse ,Biorreator de membranas ,ENGENHARIAS::ENGENHARIA CIVIL [CNPQ] - Abstract
The exalted population growth rate observed through the years reflects a higher water demand. This natural resource is not found homogeneous in state of nature and it becomes scarce in many regions, so the dispute over its use is one of the consequences. Given the delicate scenario, it is very important to adopt actions that provides the conservation of water in various activities. The industrial sector is responsible for a large part of the consumption of drinking water, maintaining the proportion for the generation and consequently discharge of effluents. The aim of this study was to evaluate the efficiency of the use of the Membrane Bioreactor (MBR) as a technology that provides better efficiency in the treatment of industrial effluents by means of replacing or combining this new technology with the conventional treatment. The effluent was characterized by physical-chemical parameters for this purpose. The LaCom was equipped with a 12L bench-scale bioreactor containing a flat plate of an ultrafiltration membrane, filled with effluents up to 10 L, for the monitoring of the removal efficiency in the biological treatment carried out. The analyzes realized were pH, sedimentable solids, Total Suspended Solids (SST), Chemical Oxygen Demand (COD) and Biological Oxygen Demand (BOD). Through the characterization of the effluent and the permeated, it was possible to calculate the average value for each parameter analyzed and the efficiencies of this treatment for some of the parameters. Total suspended solids presented 92.4%, COD analyzed with Pastel UV revealed 96.5 %, COD conventionally analyzed reached 99% and BOD 92.2%. The results allowed to verify and to prove the efficiency of the treatment of this type of industrial effluent by means of an ultrafiltration membrane. From analyzes and with the intention of applying the reuse in the industry, it was concluded that the permeated came out as expected, achieving a very satisfactory removal efficiency. Moreover, it can be reused in some industrial processes, always taking into account the type of process with the required quality. However, existing legislation and standards superficially addresses the reuse. When in fact it would be a priority to be discussed and applied in industries or other establishment. Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES Financiadora de Estudos e Projetos - Finep O elevado índice de crescimento populacional observado ao longo dos anos reflete em uma maior demanda de água. Por esse recurso natural não ser encontrado de forma homogênea na natureza, torna-se escasso em muitas regiões, assim a disputa pelo seu uso é uma das consequências. Diante do delicado cenário, é de grande relevância a adoção de medidas que proporcionam a conservação da água nas diversas atividades. O setor industrial é responsável por grande parte do consumo de água potável, mantendo a proporção para a geração e consequentemente lançamento de efluentes. Com isso, o presente trabalho foi realizado com o objetivo de avaliar a eficiência da utilização do Biorreator de Membranas (BRMs), como uma tecnologia que proporciona uma melhor eficiência ao tratamento de efluentes industriais, por meio de substituição ou combinação dessa nova tecnologia ao tratamento convencional. Para isso o efluente foi caracterizado por meio de parâmetros físico-químicos. Foi instalado no LaCom um biorreator de bancada com capacidade total de 12 L, contendo uma placa plana de uma membrana de ultrafiltração, sendo preenchido com efluentes até os 10 L, afim de verificar a eficiência de remoção e o comportamento de alguns parâmetros ao longo do tratamento biológico realizado. As análises realizadas foram de pH, Sólidos Sedimentáveis, Sólidos Suspensos Totais (SST), Demanda Química de Oxigênio (DQO) e Demanda Biológica de Oxigênio (DBO). Com a caracterização do efluente e do permeado, foi possível calcular as médias para cada parâmetro analisado, além das eficiências alcançadas dos sólidos suspensos totais com 92,4%, DQO analisada com o Pastel UV obtendo 96,5%, DQO analisada de forma convencional chegando a 99% e DBO de 92,2%. Os resultados obtidos permitiram verificar e comprovar a eficiência do tratamento desse tipo de efluente industrial por meio de uma membrana de ultrafiltração. A partir dessas análises e com a intensão de aplicar o reúso na indústria, foi concluído que o permeado saiu como o esperado, alcançando uma eficiência de remoção muito satisfatória, podendo ser reutilizado em alguns processos da indústria sempre levando em consideração o tipo de processo com a qualidade requerida. No entanto, as legislações e normas existentes deixam a desejar, quando abordam de forma superficial o reúso. Quando na verdade era para ser uma prioridade a ser discutida e aplicada nas indústrias ou em qualquer outro estabelecimento.
- Published
- 2017
33. Effluent use in an automotive industrial complex
- Author
-
Denise Maria Lenz and Sandro Carlos Pohl
- Subjects
010501 environmental sciences ,cooling towers ,01 natural sciences ,lcsh:TD1-1066 ,chemistry.chemical_compound ,Settling ,Water cooling ,Aerated lagoon ,indústria automotiva ,Cooling tower ,lcsh:Environmental technology. Sanitary engineering ,lcsh:TA170-171 ,Waste Management and Disposal ,Phosphoric acid ,Effluent ,0105 earth and related environmental sciences ,automobile industry ,Environmental engineering ,04 agricultural and veterinary sciences ,efluente industrial ,Filter (aquarium) ,lcsh:Environmental engineering ,reuse ,chemistry ,040103 agronomy & agriculture ,0401 agriculture, forestry, and fisheries ,Environmental science ,Aeration ,reúso ,effluent ,torres de resfriamento - Abstract
RESUMO Neste trabalho, realizaram-se modificações nos sistemas produtivo e de tratamento de efluentes em um complexo industrial automotivo a fim de possibilitar a utilização do efluente tratado no sistema de torres de resfriamento. Inicialmente, realizou-se um balanço hídrico nos processos industriais para determinar o consumo de água e analisou-se a qualidade do efluente tratado quanto aos parâmetros físico-químicos em dois pontos do sistema de tratamento de efluentes: no decantador secundário (P1) do tratamento físico-químico e na saída da lagoa de polimento (P2). Essas análises mostraram que o efluente tratado no decantador secundário não tem capacidade de atender às especificações da água de circulação das torres de resfriamento sem a realização de muitas alterações em seu tratamento, optando-se pela utilização do efluente tratado na saída da lagoa de polimento após modificações, como: alteração na concentração de ácido fosfórico e de ácido nítrico da solução de limpeza dos tanques de fosfatização, elevação em 50% da capacidade de aeração da lagoa aerada e troca do coagulante sulfato de alumínio pelo cloreto férrico no tratamento físico-químico. Assim, os parâmetros do efluente tratado na lagoa de polimento aproximaram-se aos parâmetros especificados para água de torres de resfriamento. A introdução desse efluente na proporção de 40% do volume da água de circulação na torre de resfriamento resultou em elevação do ciclo de dureza e redução no ciclo de sílica. A utilização de um filtro abrandador na saída da lagoa de polimento proporcionou a redução dos parâmetros de qualidade da água para valores similares aos da água de recirculação nas torres de resfriamento. ABSTRACT In this work, some changes in the productive system and in the effluent treatment plant of an automotive industrial complex have been performed in order to enable the treated effluent use in the cooling towers of the industry. Initially, a hydric balance in the industrial processes was performed, allowing the determination of water consumption. After, the effluent quality was analysed through its physico-chemical parameters at two sites of the effluent treatment plant: in the secondary settling tank (P1) of the physico-chemical treatment and in the exit of the polishing pond (P2). These analyses showed that the effluent from the settle tank does not have the ability to contemplate the specifications for water used in the cooling towers without much change in effluent treatment so that the effluent from polishing pond was used for testing in the cooling towers after some changes. These changes have included: phosphoric acid and nitric acid concentration changes in the cleaning solution of phosphating tanks, 50% increase in the aeration capacity of the aerated lagoon and replacement of aluminum sulfate coagulant by ferric chloride in physico-chemical treatment. With these modifications, the effluent from polishing pond approached the parameters specified for water cooling towers. The use of this treated effluent as 40% of water volume of the cooling tower resulted in hardness cycle increase and reduction in silica cycle. The use of a softener filter after the polishing pond decreased the effluent quality parameters to similar values to those for water cooling towers.
- Published
- 2017
34. Study of laundry wastewater treatment using combined process of coagulation/flocculation and membrane separation
- Author
-
Cardoso, Camila de Oliveira, Veit, Márcia Teresinha, Klen, Márcia Regina Fagundes, Gonçalves, Gilberto da Cunha, Palácio, Soraya Moreno, and Silva, Gracinda Marina Castelo da
- Subjects
Tanfloc coagulant ,Industrial wastewater ,Membrana ,Natural coagulant ,Toxicity ,Reuso ,Coagulante natural ,Membrane ,Efluente industrial ,ENGENHARIA QUIMICA [ENGENHARIAS] ,Coagulante Tanfloc ,Reuse ,Toxicidade - Abstract
Submitted by Marilene Donadel (marilene.donadel@unioeste.br) on 2022-02-23T17:11:14Z No. of bitstreams: 1 Camila_Cardoso_2017.pdf: 2087018 bytes, checksum: 18c2feb9ebaca335deeddc372b8202b9 (MD5) Made available in DSpace on 2022-02-23T17:11:14Z (GMT). No. of bitstreams: 1 Camila_Cardoso_2017.pdf: 2087018 bytes, checksum: 18c2feb9ebaca335deeddc372b8202b9 (MD5) Previous issue date: 2017-03-13 Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES Industrial laundries wastewaters have in your composition a large amount of dirty that leaving the washed items and chemical additives used during the washing process. In this paper, aiming the treatment of this type of effluent was studied the combined process of coagulation-flocculation (C/F) and membrane separation. Three natural coagulants (Tanfloc POP, Tanfloc SG and Tanfloc SL) were tested in C/F process searching to determine the best color and turbidity removal in the shortest settling time. The statistical analysis and coagulant acquisition cost were decisive in selection of the best natural coagulant. The highest removal of the parameters color (88.7%) and turbidity (92.8%) as well as the lowest cost showed Tanfloc POP coagulant for subsequent testing of Doehlert experimental design. The experimental design results indicated the concentration of coagulant Tanfloc POP equal to 110 mg L-1 and pH of 6.4 as the best experimental condition to obtain the supernatant used in sequential membrane filtration tests. Microfiltration (MF) and ultrafiltration (UF) membranes were tested at pressures 0.6, 1.0 and 1.4 bar in relation to permeate flow. The MF membrane at pressure of 1.4 bar showed the highest value of permeate flow as well as the largest removal of studied parameters. The combined process coagulation/flocculation/membrane was efficient to remove the analyzed parameters, reaching remove of 99.1% to turbidity and 98.4% of color at pressure of 1.4 bar. The permeate obtained in this condition of C/F-MF of combined process was classified in Class 2, 3 and 4 of reuse waters proposed by ABNT-NBR-13969/97 for floors washing, gardens irrigation and flushing toilets. Os efluentes de lavanderias industriais têm na sua composição uma elevada quantidade de sujeiras, que saem dos itens que foram lavados, e aditivos químicos utilizados durante o processo de lavagem. No presente trabalho, visando o tratamento deste tipo de efluente foi estudado o processo combinado de coagulação/floculação (C/F) e separação por membranas. Três coagulantes naturais (Tanfloc POP, Tanfloc SL e Tanfloc SG) foram testados no processo de C/F buscando determinar as melhores porcentagens de remoção de cor e turbidez no menor tempo de sedimentação. A análise estatística e de custo de aquisição do coagulante foram determinantes na seleção do melhor coagulante natural. A maior remoção dos parâmetros cor (88,7%) e turbidez (92,8%), bem como menor custo apontaram o coagulante Tanfloc POP para os ensaios subsequentes do planejamento experimental de Doehlert. Os resultados do planejamento indicaram a concentração de coagulante Tanfloc POP igual a 110 mg L-1 e pH igual a 6,4 como a melhor condição experimental para obtenção do sobrenadante utilizado nos ensaios sequenciais de separação por membranas. Foram testadas membranas de micro (MF) e ultrafiltração (UF) nas pressões de 0,6, 1,0 e 1,4 bar em relação ao fluxo permeado. A membrana MF na pressão de operação de 1,4 bar apresentou o maior valor do fluxo permeado, bem como as maiores remoções dos parâmetros estudados. O processo combinado de coagulação/floculação/membranas demonstrou ser eficiente para remoção dos parâmetros analisados, chegando a remover 99,1% da turbidez e 98,1% de cor na pressão de 1,4 bar. O permeado obtido nesta condição do processo combinado C/F-MF enquadrou-se em águas de reuso de classe 2, 3 e 4 propostos pela norma ABNT-NBR-13969/97 para fins de lavagens de pisos, irrigação de jardins e descargas de vasos sanitários.
- Published
- 2017
35. Estudo da Eficiência da Eletrocoagulação Aplicada a Efluente da Produção de Bebidas Não Gaseificadas e Não Alcoólicas
- Author
-
FOGACA, F. C., BARTHUS, R. C., Raquel Machado Borges, and JESUS, H. C.
- Subjects
Fenton ,Fotofent ,Efluente Industrial ,Eletrocoagulação ,POA - Abstract
Made available in DSpace on 2018-08-01T21:58:45Z (GMT). No. of bitstreams: 1 tese_10234_Dissertac a o Fernando Fogac a.pdf: 1885054 bytes, checksum: 330d0f1f3d296b8a77370c64f70b25e8 (MD5) Previous issue date: 2016-08-30 O presente trabalho teve como principal objetivo estudar uma rota de tratamento para o efluente da produção de bebidas não alcoólicas e não gaseificadas, com uma etapa de eletrocoagulação. Como parâmetros analíticos foram monitorados condutividade, pH, temperatura, DQO e turbidez. Outros parâmetros como densidade de corrente e densidade de carga foram avaliados para otimização dos processos. Foram testados os processos de tratamento: Eletrocoagulação, Eletrocoagulação seguida de Fenton, Eletrofenton e Eletrocoagulação seguida de Fotofenton Solar. O efluente de estudo era proveniente de uma empresa situada no Espírito Santo, que é fabricante de sucos prontos para beber, chás e isotônicos. As características do efluente, tais como a heterogeneidade, a alta concentração de DQO e sua elevada acidez, representam os maiores desafios para o tratamento. As amostras foram coletadas e enviadas ao LQA na UFES para os ensaios de tratamento e posterior análise dos parâmetros físico-químicos. A eletrocoagulação não mostrou rendimento suficiente para ser utilizada como única rotina de tratamento para este efluente, o que fez ser necessária a utilização do reagente fenton em três diferentes processos. O eletrofenton apresentou bons resultados, da ordem de 40% de remoção de DQO, mas o processo mais eficiente foi a eletrocoagulação seguida de fenton com remoções de até 60%. A eletrocoagulação seguida de fotofenton solar foi uma técnica promissora, mas precisa ser otimizada. Com o resultado desta pesquisa foi possível observar que há a viabilidade se aplicar a rota de eletrocoagulação seguida de fenton para o tratamento do efluente de bebidas não alcoólicas e não gaseificadas, desde que se adeque a aparelhagem para a realidade industrial.
- Published
- 2016
36. Estratégia sustentável na remediação de cromo em efluente industrial utilizando matriz magnética
- Author
-
Souza, Daiane Requião de, Romão, Luciane Pimenta Cruz, and Cunha, Graziele da Costa
- Subjects
Chromium ,QUIMICA [CIENCIAS EXATAS E DA TERRA] ,Resíduos industriais ,Purificação de resíduos industriais ,Redução de resíduos ,Ferromagnetismo ,Indústria de couro ,Couros ,Química ,Cromo ,Ferrita de cobalto ,Catalytic reduction ,Adsorventes ,Magnetics ,Industrial effluent ,Adsorção ,Adsorbents ,Redução catalítica ,Efluente industrial ,Magnéticos ,Cobalt ferrite - Abstract
Fundação de Apoio a Pesquisa e à Inovação Tecnológica do Estado de Sergipe - FAPITEC/SE The presence of high concentrations of toxic metals in water bodies requires a constant search for new and more effective methods to treat industrial waste. The present work proposes a technique for the removal of chromium present in leather tannery effluent, using a hybrid magnetic adsorbent, CoFe2O4/NOM, synthesized using an environmentally friendly procedure. Salts of the metals (Co and Fe) were used as precursors and natural organic matter (NOM) was used as the gelification agent, replacing the traditional reagents that are toxic and expensive. Comparisons were made of CoFe2O4/NOM produced at ambient temperature (FeAMB) and the materials produced after calcination at 200 (Fe200), 400 (Fe400), and 800 °C (Fe800). The materials were analyzed by X-ray diffractometry and infrared spectroscopy, which revealed the presence of NOM in the structure of the material, together with the formation of cobalt ferrite, hence confirming the suitability of the new synthesis route. Adsorption tests, performed as a function of pH and time, showed the effectiveness of FeAMB at the natural pH of the effluent (pH 4.2), while at pH 6.0 the removal percentages were approximately 94, 100, 98, and 89% for FeAMB, Fe200, Fe400, and Fe800, respectively, with corresponding equilibration times of 60, 120, 120, and 60 minutes, respectively. Kinetics assays showed that high adsorption of 70-87% was achieved after only 20 minutes. The adsorption kinetics could be fitted using a pseudo-second order model, and the likely removal mechanism was electrostatic attraction between carboxylate groups and the cationic chromium species CrOH2+ and Cr(OH)2 +. Amongst the adsorbents studied, the FeAMB/NOM hybrid material was especially attractive because it did not require heat treatment and showed high removal capacities during five reuse cycles, ranging from 96% in the first cycle to 82% in the fifth cycle. The residues remaining after the reuse cycles, comprising the FeAMB hybrid saturated with chromium (FeAMB_Sat) and the desorbed chromium solution (dried and calcined at 500 °C, denoted CrD), showed excellent catalytic activity in the reduction of 4-nitrophenol to 4-aminophenol, the latter being an important compound used in the synthesis of pharmaceuticals and corrosion inhibitors. The conversion rates and times were 99.9% and 55 seconds for vi FeAMB_Sat, and 99.9% and 3 seconds for CrD. A magnetic hybrid material (denoted FeSF) was also synthesized replacing the analytical grade iron salt precursor by a ferric sulfate solution derived from the treatment of iron ore mining waste. This hybrid was highly efficient as an adsorbent, with 98% removal of chromium present in an industrial effluent in only 20 minutes. The technique described here contributes to the development of industrial symbiosis since it uses materials prepared using natural substances and enables the reuse of waste in the production cycle. The procedure is a technologically viable alternative for the remediation of metal-contaminated effluents. O aumento da concentração de metais tóxicos nos corpos hídricos impulsiona uma busca constante por tratamentos eficientes para remediar resíduos industriais. Portanto, neste trabalho é proposto a remediação do cromo existente em efluente industrial de curtimento de couro utilizando um adsorvente híbrido magnético, CoFe2O4/MON, sintetizado por uma rota modificada, eco-amigável. Utiliza-se como precursores sais dos metais de interesse e a matéria orgânica natural (MON) como substância gelificante, em substituição aos reagentes tradicionais que são tóxicos e de alto custo. Para fins comparativos, a CoFe2O4/MON obtida à temperatura ambiente (FeAMB) foi calcinada a 200 (Fe200), 400 (Fe400) e 800°C (Fe800) e a formação do material foi confirmada por difratometria de raios x, que indicou também, simultaneamente, com o infravermelho, a presença da MON na estrutura do material, a formação da ferrita de cobalto e assim, a eficácia da rota de síntese proposta. Os ensaios de adsorção em função do pH e do tempo, evidenciaram a eficiência da FeAMB, no pH natural do efluente (4,2), enquanto que para os demais, no pH 6,0; com percentuais de remoção de aproximadamente 94, 100, 98 e 89% para FeAMB, Fe200, Fe400, Fe800, respectivamente, e tempos de equilíbrio de 60, 120, 120 e 60 minutos. Entretanto, com apenas 20 minutos de ensaios cinéticos houve uma alta resposta de adsorção, entre 70-87%. A cinética de adsorção ajustou-se melhor ao modelo de pseudo-segunda ordem e o possível mecanismo de remoção ocorre por atração eletrostática entre os grupos carboxilatos e as espécies catiônicas do cromo, CrOH2+, Cr(OH)2 +. O material híbrido FeAMB/MON destaca-se entre os demais adsorventes em estudo por não ter sido submetido a tratamento térmico e porque apresentou uma elevada capacidade de remoção após ser submetido a cinco ciclos de reutilização, variando de 96% no primeiro ciclo para 82% no quinto ciclo. Os resíduos decorrentes dos ciclos de reutilização, o híbrido FeAMB saturado com cromo (FeAMB_Sat) e a solução de cromo dessorvido, seca e calcinada a 500°C (CrD), apresentaram excelentes potenciais catalíticos na redução do 4- nitrofenol a 4-aminofenol, o qual é um importante insumo para a síntese de produtos farmacêuticos e inibidores de corrosão. A taxa e o tempo de conversão da redução, foram de 99,9% e 55 segundos para FeAMB_Sat e 99,9% e 3 segundos para CrD. De modo eminente, também foi sintetizado um material híbrido magnético substituindo o precursor sal de ferro em grau analítico por solução de sulfato férrico oriunda de um resíduo tratado da mineração de ferro, denominado FeSF. Este híbrido revelou uma eficiência notável como adsorvente, pois o percentual de remoção de cromo presente em efluente industrial foi de 98% em apenas 20 minutos. Diante disso, o presente estudo contribuiu para a prática da simbiose industrial ao propor o emprego de substâncias naturais na elaboração de materiais, bem como a reutilização dos resíduos, e sua reinserção no ciclo produtivo desenvolvendo uma alternativa tecnologicamente viável para remediação de metais.
- Published
- 2016
37. Uso de extrato de levedura como fonte de carbono e de mediadores redox, para a degradação anaeróbia de corante azo Use of yeast extract as source of carbon and redox mediators for the anaerobic degradation of azo dyes
- Author
-
Cássia Aparecida Rabelo Corrêa, Sérgio Francisco de Aquino, Paula Cristina de Paula Caldas, and Silvana de Queiroz Silva
- Subjects
tratamento anaeróbio ,ácidos graxos voláteis ,volatile fatty acids ,efluente industrial ,corantes azo ,yeast extract ,azo-dyes ,industrial effluent ,lcsh:TD1-1066 ,lcsh:Environmental engineering ,redox mediators ,extrato de levedura ,anaerobic treatment ,mediadores redox ,lcsh:Environmental technology. Sanitary engineering ,lcsh:TA170-171 - Abstract
O trabalho investigou a influência do uso do extrato de levedura, fonte dos mediadores redox riboflavina e nicotinamida, na remoção de cor de solução de corante azo Drimaren Azul HF-RL em condições anaeróbias. O trabalho envolveu a execução de ensaios em batelada, em frascos-reatores mantidos a 25 ºC, incubados com o azo-corante e lodo anaeróbio na presença e ausência de fontes de carbono (extrato de levedura ou glicose) e de mediadores redox (riboflavina ou extrato de levedura). O monitoramento da variação temporal de cor, a demanda química de oxigênio (DQO) e ácidos graxos voláteis (AGV) mostraram que a adição de extrato de levedura (0,5 g/L) resultou em eficiências de remoção de cor de 80 a 85% nas primeiras 24 horas de incubação, e que os produtos da degradação do azo-corante foram tóxicos para todo o consórcio anaeróbio, o que resultou em baixas eficiências de remoção de DQO na presença e ausência do extrato de levedura. Os resultados indicaram, ainda, que as eficiências de remoção de cor foram inferiores a 30% na presença de apenas glicose (fonte de carbono) ou riboflavina (mediador redox), indicando que o extrato de levedura atuou simultaneamente como fonte de carbono e de mediadores redox.This paper investigated the influence of using yeast extract, which is the source of redox mediators riboflavin and nicotinamide, in the decolorization of solutions containing the azo dye Drimaren Blue HF-RL in anaerobic conditions. It involved the incubation of serum bottles kept at 25 ºC and inoculated with the azo-dye, and anaerobic sludge in the presence and absence of carbon source (glucose or yeast extract) and redox mediators (riboflavin and yeast extract). The monitoring of color, chemical oxygen demand (COD) and volatile fatty acids (VFA) showed that the addition of yeast extract (0.5 g/L) resulted in 80 to 85% color removal in the first 24 hours of incubation; and that the metabolites of dye degradation were toxic to the anaerobic microorganisms, which led to low COD removal efficiencies either in the presence or absence of yeast extract. The results also showed that the efficiencies of color removal were below 30% in the presence of only glucose or riboflavin, indicating that the yeast extract acted simultaneously as source of carbon and redox mediators.
- Published
- 2009
38. Otimização de uma estação de tratamento de efluentes de uma indústria de embalagens de papel Optimization of a cardboard paper factory wastewater treatment plant
- Author
-
Lademir Luiz Beal, Luiz Olinto Monteggia, and Saulo Varela Della Giustina
- Subjects
foaming control ,Otimização de processos ,industrial wastewater ,Controle de "Foaming" ,activated sludge ,Lodos ativados ,lcsh:Environmental technology. Sanitary engineering ,lcsh:TA170-171 ,efluente industrial ,lcsh:TD1-1066 ,Process optimization ,lcsh:Environmental engineering - Abstract
Este trabalho versa sobre a utilização de uma estratégia de otimização de uma estação de tratamento de efluentes de uma indústria de embalagens de papel, com problemas de "foaming". Os resultados do diagnóstico inicial mostraram que o tratamento primário alcançou uma eficiência superior a 70% na remoção de sólidos suspensos. As modificações operacionais realizadas foram limpezas das caixas de gordura, redução da geração de óleos e graxas nos pontos de geração. As modificações no processo na ETE foram à implementação da equalização da vazão de alimentação do tanque de aeração, adição de hipoclorito de sódio na entrada do sedimentador secundário, adição de ácido fosfórico para equilibrar a relação entre nutrientes e DBO5 e a manutenção de uma concentração e idade do lodo constante durante o processo.This paper describes the strategies used to optimize a cardboard paper factory wastewater treatment plant regarding operational problems caused by the occurrence of foaming and filamentous organisms. The operational modifications involved the use of an equalization tank, the reduction of oil and grease from the industrial process, the addition of sodium hypochlorite at the inlet of the secondary settler to control filamentous organisms and phosphoric acid to correct the nutrients balance and BOD. A correct value of biomass concentration and sludge age were maintained constant all the time. The first results showed that the TSS removal efficiency in the primary settler was higher than 70%, followed by an improved performance of the biological reactor due to the control of filamentous organisms and better performance of the secondary settler.
- Published
- 2006
39. IMPLANTAÇÃO DE UM LABORATÓRIO DE ANÁLISE DA QUALIDADE DA ÁGUA E EFLUENTES DE UMA INDÚSTRIA FARMACÊUTICA
- Author
-
Letícia Franco and Patrícia Bilotta
- Subjects
Indicador de qualidade ,água industrial ,efluente industrial ,purificação da água ,reuso de água ,General Medicine - Abstract
A agua para fabricacao de farmacos demanda qualidade rigorosa, por isso requer sucessivas etapas de purificacao para atender as determinacoes da legislacao brasileira. Da mesma forma, o efluente gerado no processo produtivo tambem exige tratamento antes do seu descarte em corpos d'agua. O monitoramento da qualidade da agua e do efluente industrial e realizado por meio de analises laboratoriais, em muitos casos, por laboratorios terceirizadas a um custo elevado. O objetivo deste artigo e identificar os parâmetros de analise da qualidade da agua e efluente de uma industria do ramo farmaceutico e propor instrumentos analiticos para a implantacao de um laboratorio analitico. O desenvolvimento da pesquisa se baseou na identificacao dos parâmetros de analise da qualidade e na aplicacao de metodologias analiticas para agua e efluente, considerando a legislacao vigente e dados da literatura. Com base nos resultados obtidos, sao recomendados os seguintes equipamentos analiticos: agitador magnetico com aquecimento, oximetro, autoclave, capela, condensador, balanca analitica, bico de Bunsen, manta de aquecimento, espectrofotometro, bomba a vacuo, banho-maria, incubadora para teste microbiologico, potenciometro, estufa, mufla, condutivimetro, extracao de Soxhlet, digestor-destilador Kjeldahl, equipamento respirometrico, incubadora (DBO). As vantagens da implantacao do laboratorio sao: reducao de custos com terceirizacao das analises; maior periodicidade das analises e controle do tratamento da agua e efluente; prestacao de servico para industrias que nao possuem laboratorio (fonte adicional de recursos); reuso de agua do processo produtivo; potencial de aproveitamento de agua chuva e reducao de custos com outorga de captacao de agua e lancamento de efluentes.
- Published
- 2014
- Full Text
- View/download PDF
40. Tratamento de resíduos industriais farmoquímicos por reagente de fenton
- Author
-
Ferreira, Taciano Peres, Viana, Júlio Cesar Vieira, Alves, Leandro Albano, and Paula, Marcio André de
- Subjects
Química ,Ciências Ambientais ,Reagente de Fenton ,Efluente industrial ,Farmoquímico ,Fenton's reagent, industrial effluent, pharmochemical - Abstract
This study aims to determine the optimal concentration of Fenton reagent for pharmaceutical chemistry industry, varying the concentration of ferrous sulfate and hydrogen peroxide subsequently monitor the treatment in pilot scale and wastewater treatment (WWTP) station of the main parameters: color, odor, pH and COD. Pilot tests to obtain the guidelines used in formulating the Fenton reagent to be used in large scale in the effluent tank were performed, the pilot test of experiment T12 showed the best result (Color and COD) for the composition of the treatment with: 3.2 mL of H2O2 and 160 mg Ferrous Sulfate. From this parameter the treatment was carried out daily monitoring in the laboratory and pilot scale, and the values were similar for both treatments, with the percentage reduction of COD of 93.57% in the lab test and 94.00% in the ETE test. The process of wastewater treatment using Fenton reagent showed excellent results, with better values than the limits established by law. But the treatment time of 16 days is not feasible for some industries, but is smoothly carried out in the study industry. O presente trabalho tem como objetivo determinar a concentração ideal do Reagente de Fenton para uma indústria farmoquímica, variando a concentração de sulfato ferroso e água oxigenada, posteriormente acompanhar o tratamento em escala piloto e na estação de tratamento de efluente (ETE) dos principais parâmetros: Cor, Odor, pH e DQO. Foram realizados ensaios pilotos para a obtenção das diretrizes empregadas na formulação do reagente de Fenton a ser utilizado em larga escala, no tanque de efluente, o teste piloto do experimento T12 foi o que apresentou melhor resultado (Cor e DQO) para a composição do tratamento com: 3,2 mL de H2O2 e 160 mg de Sulfato Ferroso. A partir deste parâmetro foi realizado o tratamento com acompanhamento diário no laboratório e em escala piloto, sendo que os valores foram similares para ambos os tratamentos, sendo o percentual de redução de DQO de 93,57% no ensaio de laboratório e 94,00% na ETE. O processo de tratamento de efluente utilizando o Reagente de Fenton apresentou ótimos resultados, com valores melhores que os limites estabelecidos pela legislação. Entretanto o tempo de tratamento de 16 dias se torna inviável para algumas indústrias, mas sendo tranquilamente realizado na indústria estudada.
- Published
- 2014
- Full Text
- View/download PDF
41. Energia solar no tratamento de corante têxtil
- Author
-
Farias Silva, Viviane, Arruda de Brito, Kalyne Sonale, Farias Silva, Vanessa, Costa Ferreira, Aline, Maracajá, Patrício Borges, Farias Silva, Viviane, Arruda de Brito, Kalyne Sonale, Farias Silva, Vanessa, Costa Ferreira, Aline, and Maracajá, Patrício Borges
- Abstract
Industries use water throughout the process, wasting huge amounts of water generating effluents with high levels of chemicals in need of treatment to be reused or released into the environment. In this context, this work was performed at the Laboratory of Environmental Engineering and Quality at Federal University of Pernambuco aiming to degradation of dye used in textile for industries through the use of solar energy as an alternative wastewater treatment. In this research the photocatalytic tests were performed with the catalyst powder (TiO2 - P25), containing the textile dye Remazol Golden Yellow RNL (RGY) or without catalyst in photolysis tests. Two types of radiation, artificial and solar energy (natural) were tested. To assess the discoloration and degradation of the samples, the UV- visible spectroscopy was the primary analytical technique but also performed analyzes of Total Organic Carbon (TOC) and Chemical Oxygen Demand (COD). In the six (6) analysis performed yielded a high degree of color removal of dye greater than 97%, high efficiency of the process with a significant reduction in the COD and TOC. The methods used were effective in discoloration of RGY, but also in degradation, becoming an innovative technique with the use of solar energy for treatment of textile effluents., As indústrias utilizam a água em todo o seu processo, desperdiçando enormes volumes de água gerando efluentes com altos índices de produtos químicos, precisando de tratamento para ser reutilizado ou lançado no maio ambiente. Nesse contexto, o presente trabalho foi realizado no Laboratório de Engenharia Ambiental e de Qualidade na Universidade Federal de Pernambuco objetivando-se a degradação de corante utilizados nas indústrias têxtis através do uso da energia solar como alternativa de tratamento de efluente. Nesta pesquisa os testes fotocatalíticos foram realizados com o catalisador em pó (TiO2 - P25), contendo o corante têxtil Remazol Amarelo Ouro RNL (RGY) ou sem catalisador nos testes de fotólise. Foram testados dois tipos de radiação, a artificial e a energia solar (natural). Para avaliar a descoloração e a degradação das amostras, a Espectroscopia UV-visível foi a principal técnica analítica empregada como também realizadas análises de Carbono Orgânico Total (COT) e Demanda Química de Oxigênio (DQO). Nas 6 (seis) analises realizadas obteve-se um elevado índice de remoção da cor do corante, superior a 97%, com alta eficiência do processo com uma significativa redução da COT e da DQO. Os métodos utilizados foram eficientes na descoloração do RGY, como também na sua degradação, tornando-se uma técnica inovadora com o uso da energia solar para o tratamento de efluentes têxteis.
- Published
- 2014
42. Adsorção de nitrogênio amoniacal de efluentes industriais, a partir da síntese da zeólita Na-P1 de cinzas pesadas de carvão
- Author
-
Böer, Sabrine Cássia de and Cunha, Ana Cristina Borba da
- Subjects
Adsorção ,Nitrogênio amoniacal ,Efluente industrial ,Zeólita Na-P1 - Abstract
Submitted by Jakeline Silva (jakeline.silva@unilasalle.edu.br) on 2016-10-19T20:59:51Z No. of bitstreams: 1 scboer.pdf: 1301851 bytes, checksum: 253c5059318107743b3740387de5986f (MD5) Made available in DSpace on 2016-10-19T20:59:51Z (GMT). No. of bitstreams: 1 scboer.pdf: 1301851 bytes, checksum: 253c5059318107743b3740387de5986f (MD5) Previous issue date: 2013 A legislação ambiental atualmente vigente impõe às indústrias geradoras de efluentes padrões de emissões cada vez mais restritivas. Desta forma, as empresas precisam se adequar a essas políticas e ajustar seus processos produtivos, adotando procedimentos que tornem estes processos mais eficazes e com menor geração e liberação de rejeitos. O objetivo principal deste trabalho é avaliar a possibilidade de remover, via adsorção por zeólitas sintetizadas a partir de cinzas pesadas de carvão mineral, o nitrogênio amoniacal presente nos efluentes do processo industrial de curtumes e de um aterro, de acordo com os padrões estabelecidos pela legislação ambiental. As cinzas pesadas geradas pela combustão de carvão mineral foram sujeitas à síntese hidrotérmica, em meio alcalino, visando à formação de zeólitas Na-P1. Para comprovar a efetiva formação destas zeólitas foram realizadas análises de Difração de Raios-X, Fluorescência de Raios-X e capacidade de troca catiônica. Após a análise dos resultados obtidos ficou comprovada a formação das zeólitas. As zeólitas Na-P1 assim produzidas foram testadas em leito fluidizado, com padrão de cloreto de amônio, utilizando efluentes de curtumes e de um aterro industrial. Foi constatada uma redução de aproximadamente 50% de nitrogênio amoniacal nos efluentes estudados. Considerando a grande dificuldade para reduzir os teores de nitrogênio amoniacal em determinados efluentes industriais, ao mesmo tempo em que permanece sem utilização a maior parte das cinzas pesadas resultantes da queima de carvão mineral, torna-se evidente a grande potencialidade do uso de zeólitas como um método alternativo para redução de nitrogênio amoniacal destes efluentes.
- Published
- 2013
43. Estudo, Monitoramento e Avaliação de Estações de Tratamento de Efluentes Industriais: Estudo de Caso de Indústrias de Polímeros e Cervejeira
- Author
-
ALCÂNTARA, Carem Vieira, SILVA, Maria do Carmo Lourenço da, and MOTTA SOBRINHO, Maurício A. da
- Subjects
Análise de Imagem ,Efluente Industrial ,Fracionamento da Matéria Orgânica - Abstract
CNPq Para o entendimento das operações do tratamento biológico de efluente o conhecimento em duas áreas são fundamentais: a microbiologia e a engenharia dos reatores. O reator biológico de uma estação de tratamento de esgotos por via biológica é um verdadeiro ecossistema, formado por várias espécies de bactérias, protozoários, metazoários e algas, tais microrganismos podem ser agrupados em formadores de flocos e filamentosas. Outro aspecto importante dentro do acompanhamento biológico trata-se da avaliação da atividade microbiana, ou seja, da capacidade em degradar o material orgânico presente nos esgotos. A realização de um estudo cinético pode avaliar o comportamento dos microrganismos, pela velocidade de degradação, como também propor um modelo matemático que represente este processo. Este trabalho teve por objetivo estudar o processo de tratamento de efluentes por via biológica, do ponto de vista microscópico e macroscópico, fornecendo informações que permitam melhorar a eficiência do processo. Este trabalho buscou incluir novas ferramentas no controle e avaliação de estações de tratamento como a análise de imagens dos flocos e micro-organismos e o fracionamento da matéria orgânica. Inicialmente foi estudada a Estação de Tratamento de Efluentes da M&G Polímeros, onde foram feitos estudos da microbiota e avaliação físico-química buscando relações entre eles. Em seguida estudou-se o efluente da cervejaria Schincariol, analisando-se a distribuição da matéria orgânica nos diversos compartimentos. Os resultados mostraram o alto potencial destas análises na melhoria da eficiências dos tratamento dos efluentes industriais.
- Published
- 2012
44. Toxicity identification and evaluation of cosmetic industry wastewater
- Author
-
Melo, Elisa Dias de, Silva, Cláudio Mudado, Barbosa, Luiz Claudio de Almeida, Mounteer, Ann Honor, and Botta, Clarice Maria Rispoli
- Subjects
Industrial effluent ,Cosméticos ,Toxicity ,ENGENHARIAS::ENGENHARIA SANITARIA::TRATAMENTO DE AGUAS DE ABASTECIMENTO E RESIDUARIAS::ESTUDOS E CARACTERIZACAO DE EFLUENTES INDUSTRIAIS [CNPQ] ,Efluente industrial ,Cosmetics ,Toxicidade - Abstract
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior Cosmetic industry wastewaters can contain a complex mixture of chemicals, representing potential toxicity to aquatic organisms when released untreated or insufficiently treated into receiving waters. Despite the importance of including ecotoxicological assessment in the wastewater monitoring, there is still the need to identify the compounds responsible for toxicity, to allow its effective reduction. The United States Environmental Protection Agency has developed a method to assist in the identification of toxic substances, known as Toxicity Identification and Evaluation (TIE), which is based on sample manipulation by a series of physical and chemical processes, aimed at separating classes of compounds to determine their potential toxicity. In this work, the TIE methodology was applied to wastewater generated at a small cosmetics industry, located in the state of Minas Gerais. The physical-chemical and ecotoxicological analysis of samples collected from the inlet and outlet of the wastewater treatment plant (WTP) revealed an inefficient operation of the system (physical-chemical processes of coagulation, flocculation, sedimentation and filtration). Organic matter, suspended solids and surfactants concentrations in the treated effluent samples exceeded the legal standards for effluent discharge. Acute and chronic toxicity testing with organisms from three trophic levels (Vibrio fischeri, Daphnia similis, Ceriodaphnia dubia and Pseudokirchneriella subcapitata) indicated high toxicity of treated effluents. After application of the procedures described in Phase I of the TIE protocol, sources of toxicity from ammonia, cationic metals and oxidant compounds were discarded, and the toxicity was associated with particulate matter, volatile or sublatable and nonpolar to moderately polar organic compounds. These results indicated surfactants, ingredients used in large quantities in the production process, as a possible source of toxicity. The evaluation of individual and combined toxicity of the major surfactants used in the industry was able to confirm this suspicion, even though other possible sources of toxicity, such as fragrances, should not be discarded. Os efluentes líquidos gerados por indústrias de cosméticos podem ser formados por misturas complexas de substâncias químicas, apresentando potencial tóxico aos organismos aquáticos quando lançados nos corpos-d água sem tratamento ou insuficientemente tratados. Apesar da importância em se englobar a avaliação ecotoxicológica no monitoramento de efluentes líquidos, há ainda a necessidade em se identificar os compostos responsáveis pela toxicidade, possibilitando a sua efetiva redução. A Agência de Proteção Ambiental dos Estados Unidos desenvolveu um método para auxiliar na identificação de substâncias tóxicas, conhecido como Avaliação e Identificação da Toxicidade (AIT), que baseia-se na manipulação das amostras através de uma série de processos físicos e químicos, objetivando separar grupos de compostos para verificar seu potencial tóxico. Neste trabalho foi aplicada a metodologia de AIT aos efluentes líquidos gerados por uma indústria de cosméticos de pequeno porte, localizada no estado de Minas Gerais. A caracterização físico-química e ecotoxicológica de amostras coletadas na entrada e na saída da Estação de Tratamento de Efluentes (ETE) para as três campanhas realizadas revelaram uma operação ineficiente do sistema de tratamento implantado (processo físico-químico de coagulação, floculação, decantação e filtração). Foram detectados teores de matéria orgânica, sólidos em suspensão totais e surfactantes em desconformidade com os padrões legais para lançamento de efluentes, e testes de toxicidade aguda e crônica com organismos de três níveis tróficos (Vibrio fischeri, Daphnia similis, Ceriodaphnia dubia e Pseudokirchneriella subcapitata) indicaram elevada toxicidade dos efluentes tratados. Após a aplicação dos procedimentos previstos na fase I do protocolo de AIT, foram descartadas as fontes de toxicidade por amônia, metais catiônicos e compostos oxidantes, sendo a toxicidade associada a materiais particulados, compostos voláteis ou subláteis e a compostos orgânicos apolares ou moderadamente polares. Tais resultados indicaram os surfactantes, ingredientes empregados em elevadas quantidades no processo produtivo, como possível fonte da toxicidade. A avaliação da toxicidade individual e combinada dos principais surfactantes utilizados na indústria puderam confirmar essa suspeita, apesar de não terem sido descartadas outras possíveis fontes, como, por exemplo, das fragrâncias empregadas.
- Published
- 2012
45. Recuperação de biomassa bacteriana produzida no tratamento de efluente industrial
- Author
-
LIMA, L. K. F. de, PONSANO, E. H. G., PINTO, M. F., LEANDRO KANAMARU FRANCO DE LIMA, CNPASA, ELISA HELENA GIGLIO PONSANO, UNESP, and MARCOS FRANKE PINTO, UNESP.
- Subjects
Colorimetria ,Demanda química de oxigênio ,Efluente industrial ,Biomassa ,Biotecnologia ,Peixe ,Rubrivivax gelatinousus - Abstract
Ultimamente, tem se observado uma crescente busca por formas alternativas para o tratamento de efluentes industriais líquidos. O cultivo de microorganismos fotossintetizantes nestes efluentes representa uma alternativa biotecnológica atrativa, pois possibilita a redução da carga poluente e gera uma massa celular com potencial de aplicação. Entretanto, para a remoção da massa celular gerada nesses processos, é necessário o emprego de tecnologias específicas. Neste trabalho, Rubrivivax gelatinosus foi cultivada no efluente líquido de indústria de abate e processamento de pescado e a biomassa foi recuperada por duas metodologias diferentes, com o objetivo de comparar a produtividade entre elas. Adicionalmente, avaliou-se a remoção da carga poluente e comparou-se a cor das massas celulares obtidas com a de um produto comercial de referência. O cultivo foi realizado sob anaerobiose, 30 ± 5ºC e 2.000 ± 500 lux, durante 10 dias, e a recuperação da biomassa foi realizada pelos processos A (utilizando-se centrifugação) e B (utilizando-se microfiltração tangencial). Pelos resultados, observou-se uma produtividade de 0,043 g biomassa L-1 dia-1 e redução de 52,51% da DQO no processo A. Em B, observou-se, respectivamente, 0,079 g biomassa L-1 dia-1 e 81,25%. As biomassas e o produto comercial apresentaram semelhante luminosidade e tonalidade. Houve diferença na saturação da cor entre o produto obtido da microfiltração e o comercial. Conclui-se que o sistema de microfiltração por membrana foi o melhor método para a obtenção da biomassa de Rubrivivax gelatinosus, promovendo uma alta redução da matéria orgânica no efluente industrial.
- Published
- 2012
46. Wastewater treatment of the glass industry with Moringa oleifera
- Author
-
Zampero, Rosangela, Cunha Neto, Francisco Rodrigues da, Silva, Roberta Bessa Veloso, and Oliveira, Magali Borges de
- Subjects
coagulante natural ,biopolímero natural ,natural coagulant ,CIENCIAS AGRARIAS::ENGENHARIA AGRICOLA [CNPQ] ,efluente industrial ,moringa oleifera ,industrial effluent - Abstract
Made available in DSpace on 2016-05-02T13:54:10Z (GMT). No. of bitstreams: 1 RosangelaZampero-dissertacaocompleta.pdf: 820803 bytes, checksum: ec31de7b8b2d172d25dda29c7917c9ef (MD5) Previous issue date: 2011-12-09 The use of biopolymers extracted from plants in the clotting process has several advantages compared with chemical salts. Among the advantages: low cost and variation in the nature of the alkalinity of the water in the process, because the sludge generated after treatment has lower volume compared with the sludge generated with the use of chemical constituents. The specific study of wastewater generated in the industry of glass quenching calls attention to the high rate of waste sludge. The effluent is a major concern regarding the disposal or reuse. In this case, the hardening process studied uses 110,000 liters of water per month, which generates 40 tons / month of solid waste and consequently large volumes of wastewater. During the study the objective was to check the behavior of Moringa oleifera seeds as natural coagulant in the effluent liquid from the glass industry and water reuse in the process. O uso de biopolímeros extraídos de vegetais no processo de coagulação tem várias vantagens em comparação com os sais químicos. Dentre as vantagens, destaca-se o baixo custo e o fato que não existe variação na natureza da alcalinidade da água no processo, pois o lodo gerado após tratamento apresenta menor volume quando comparado com o lodo gerado com uso de constituintes químicos. O estudo dos efluentes líquidos gerados na indústria de têmpera de vidros chamou a atenção pelo alto índice de lodos residuais. Este efluente é a grande preocupação quanto ao seu descarte ou reuso. Neste caso, o processo de têmpera estudado utiliza 110 mil litros de água por mês, que gera 40 ton./mês de efluentes sólidos e consequentemente grande volume de efluente líquido. No decorrer do estudo objetivou-se verificar o comportamento das sementes de Moringa oleifera como coagulante natural no efluente líquido da indústria de vidros e reuso da água no processo.
- Published
- 2011
47. De um subproduto industrial para um produto destinado à alimentação animal: produção de biomassa bacteriana
- Author
-
Lima, Leandro Kanamaru Franco de [UNESP], Torres, Ane Pamela Capucci [UNESP], Santo, Edson Francisco do Espirito [UNESP], Ponsano, Elisa Helena Giglio [UNESP], and Universidade Estadual Paulista (Unesp)
- Subjects
Nutrição animal ,Pigmentação ,Efluente industrial ,Rubrivivax gelatinosus ,Pescado - Abstract
Made available in DSpace on 2016-01-28T16:52:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2011. Added 1 bitstream(s) on 2016-01-28T17:00:10Z : No. of bitstreams: 1 ISSN1679-4605-2011-07-01-145.pdf: 42365 bytes, checksum: 69f3ec618ea954810efa853a74424986 (MD5) A grande diversidade das atividades industriais ocasiona durante o processo produtivo a geração de resíduos sólidos, líquidos e gasosos, que podem poluir e/ou contaminar o solo, a água e o ar. Embora existam regulamentos para o descarte desses resíduos, a inobservância às regras, a ineficiência dos tratamentos despoluentes e a inoperância de órgãos fiscalizadores permitem que, ainda hoje, sejam lançados ao ambiente grandes cargas de poluentes. Isso se aplica às indústrias de alimentos de origem animal. Felizmente, a visão dos empresários do setor vem mudando, na medida em que a imagem de uma empresa que conta com produtos e processos ambientalmente responsáveis representa parte das estratégias competitivas atuais. O objetivo deste trabalho foi demonstrar como um efluente industrial pode ser transformado em matéria prima para a obtenção de um produto com valor comercial, utilizando tecnologias reconhecidas pela indústria e a atividade microbiana. O efluente foi obtido em indústria de abate e processamento de tilápias, apresentado (valores médios) pH = 9,4, DQO = 1.127 mg/L, óleos e graxas = 1.166 mg/L, nitrogênio total = 813 mg/L, coliformes a 30–35o C = 1,0x105 NMP/mL, coliformes a 45o C = 0,41 NMP/mL, bolores e leveduras = 4,6x103 UFC/mL e, ocasionalmente, contendo Salmonella sp e Aeromonas sp. Os tratamentos físicos aplicados ao efluente incluíram gradeamento, filtração (50µm) e pasteurização (65o C/30 min). O cultivo de Rubrivivax gelatinosus foi realizado sob anaerobiose em reatores de vidro durante 7 dias, em temperatura ambiente (30±5o C) e 2.000±500 lux. A recuperação da biomassa foi feita por filtração tangencial (0,2 µm; 1,5 bar), centrifugação (3.400 g/30 min; 5o C) e liofilização (-40o C) e a pulverização foi realizada manualmente. A produção de massa celular atingiu 0,18 g/L, com produtividade de 0,0634 g/L.dia. O processo promoveu redução de 52% na DQO, 48% em óleos e graxas e 22% no nitrogênio total, gerando um resíduo com pH 7,9, livre de bactérias patogênicas e, portanto, apto ao descarte. O produto obtido apresentou cor vermelho escuro (L = 22,42; C = 14,22; h = 25,48), 4,55% de umidade, 57,39% de proteína, 11,08% de extrato etéreo, 4,05% de matéria mineral, 3,03 mg/g de oxicarotenóides, 20,27 NMP/g de coliformes a 30–35o C
- Published
- 2011
48. Eficacia de coagulantes en el tratamiento primario de efluentes de procesadora de frutas
- Author
-
Alcarraz C, Mario, Gamarra B, Gerardo, Castro L, Américo, and Godoy A, Juan
- Subjects
coagulación ,floculación ,flocculation ,efluente industrial ,Tratamiento primario ,Primary treatment ,coagulation ,industrial effluent - Abstract
Industrial effluents without treatment or supervision by the authorities pollute the environment. Solving the problem does not go only by the control, supervision and penalties for companies that generate effluents, require its own investigation as well as develop specific treatments, accessible and affordable that can be adopted by each industry. The primary treatment is removal by physical or chemical means a substantial part of sedimentable or floating material, reducing an important fraction of the organic load, which represents a significant percentage of solid contaminants. Within the types of primary treatment quote coagulation and flocculation. The main objective was to evaluate the efficacy of two coagulants in reducing the pollution potential of effluents from the fruit processing plant. To make the primary treatment: were assayed two chemical substances, aluminum sulfate as inorganic coagulant and other organic, the Polycat CS-5460. The effectiveness was determined by turbidity assays, biochemical oxygen demand and total solids. We conclude that the best coagulant for the removal organic matter in effluents from the processing of fruit is the Polycat CS-5460 having achieved an important removal of turbidity (98.1%) and reduction of biochemical oxygen demand (96.58%) within allowable limits for discharge of industrial effluents, according peruvian law., Los efluentes industriales sin tratamiento previo ni control de las autoridades contaminan el medio ambiente. Resolver el problema planteado no pasa solamente por el control, supervisión y sanción a las empresas generadoras de efluentes, requieren además de una investigación propia para desarrollar tratamientos específicos, accesibles y económicos que puedan ser adoptados por cada tipo de industria. El tratamiento primario consiste en la remoción, por medios físicos o químicos, de una parte sustancial del material sedimentable o flotante, reduciendo una fracción importante de la carga orgánica, que representa porcentajes significativos de los sólidos contaminantes. Entre los tipos de tratamiento primario se utilizan: la coagulación y la floculación. El objetivo principal del trabajo fue evaluar la eficacia de dos coagulantes en la reducción del potencial contaminante de los efluentes de la planta procesadora de frutas. Para realizar el tratamiento primario se ensayaron dos coagulantes químicos, el sulfato de aluminio como inorgánico y el Polycat CS-5460 como orgánico. La eficacia se determinó con los ensayos de turbidez, demanda bioquímica de oxígeno y sólidos totales. Se concluye que el mejor coagulante para la remoción de la materia orgánica de los efluentes de la procesadoras de frutas es el Polycat CS-5460 habiendo logrado una remoción de turbidez de 98,1% y la reducción de la demanda bioquímica de oxígeno de 96,58%, valores que se encuentran dentro de los límites permisibles para la descarga de efluentes industriales, según la legislación peruana.
- Published
- 2010
49. Avaliação dos fatores abióticos e bióticos de uma área petroquímica da região de Paulínia, SP, e fotodocumentação dos fungos transientes isolados
- Author
-
Cruz, Aline da Silva [UNESP], Universidade Estadual Paulista (Unesp), Angelis, Derlene Attili de [UNESP], and Pagnocca, Fernando Carls [UNESP]
- Subjects
Industrial effluent ,Cultura e meios de cultura (Biologia) - Acervo ,Leveduras (Fungos) - Engenharia genetica ,Efluente industrial ,Paulinia (SP) ,Fungos ,Fungal diversity ,Fungos filamentosos ,Diversidade fúngica - Abstract
Made available in DSpace on 2014-06-11T19:27:24Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-07-12Bitstream added on 2014-06-13T19:35:29Z : No. of bitstreams: 1 cruz_as_me_rcla.pdf: 2096941 bytes, checksum: e034fe58bade607f70d6be667b1b3079 (MD5) A ocupação do solo e a demanda de água doce tem sido crescente, de maneira que pesquisas voltadas à avaliação da qualidade das águas em áreas estratégicas são consideradas fundamentais. Neste contexto, a área de estudos foi escolhida pela disponibilidade de água, distribuição demográfica e pela sua importância industrial. Com o propósito de melhor compreender o impacto causado pelo efluente do pólo petroquímico de Paulínia, SP, na qualidade das águas do rio Atibaia, os parâmetros potencial hidrogeniônico (pH), temperatura da água, sólidos totais, turbidez, oxigênio dissolvido (OD), demanda bioquímica de oxigênio (DBO), nitrogênio total (NT), íons fósforo (íons P), pluviosidade, estações seca e chuvosa, condutividade elétrica da água e concentração de cloretos foram analisados. Verificou-se, ainda, a influência dos parâmetros mencionados sobre a micobiota transiente de amostras coletadas no período entre agosto de 2007 a março de 2009. O método de plaqueamento para contagem dos fungos e as análises físicas e químicas seguiram Clesceri et al. (1998). Correlação de Pearson, análise de variância multivariada, correlação canônica para dados multivariados e análise dos componentes principais foram as análises estatísticas realizadas. Estas revelaram diferentes influências dos parâmetros independentes sobre as contagens fúngicas. A micobiota transiente detectada no período estudado foi sensível aos parâmetros cloretos, sólidos totais, condutividade elétrica da água e OD, pois estes fatores abióticos influenciaram negativamente nas contagens. Entretanto, o número de colônias de fungos foi estimulada positivamente pela pluviosidade (estação chuvosa), DBO, turbidez e NT. Das análises estatísticas, apenas a correlação de Pearson pareceu não ser eficiente para estudos ambientais sujeitos a variações diversas The use of the soil and fresh-water has increased, so that investigations on the water quality in strategic areas are considered of fundamental importance. In this context, the study area was chosen for its water availability, demographic distribution and industrial relevance. With an eye on the water quality of the influence of an industrial effluent discharged in the Atibaia river, in the surroundings of a petrochemical refinery in Paulínia, SP, the following parameters were analyzed: pH, water temperature; total dissolved solids; turbidity; dissolved oxygen (DO); biochemical oxygen demand (BOD), total nitrogen (TN), phosphorous; rain; dry and rain seasons; water conductivity and chlorides. Also, the influence of these parameters on transient mycota between August 2007 and March 2009 was investigated. The method for counting the forming colony units of fungi was according to Clesceri et al. (1998). Pearson correlation coefficient, multivariate analysis of variance, canonical correlation to multivariate data and principal component analysis were the statistical methods employed. The results revealed differences in the influence of the independent parameters on the counting of fungal colony forming units (CFU). The fungi present in the samples were negatively affected by chloride concentration, total dissolved solids, water conductivity and DO. However, the CFU was increased by the rain, BOD, turbidity and TN. Among the statistical tests used, only Pearson correlation was not satisfactory for our studies
- Published
- 2010
50. Variabilidade interanual (10 anos) da comunidade zooplanctônica na região costeira do Espírito Santo, em área sob influência de efluente industrial aquecido
- Author
-
Campelo, Rodolfo Pessotti Messner and Sant'Anna, Eneida Maria Eskinazi
- Subjects
Ecologia aquática ,Ecologia de ecossistemas ,Efluente industrial ,Zooplâncton - região costeira - ES - Abstract
Na ultima década (1998-2007) foram realizadas coletas de dados bióticos (zooplâncton) e abióticos (temperatura e salinidade), nas águas da região costeira adjacente à Praia Mole, no Espírito Santo, com o objetivo de monitorar os efeitos potenciais do descarte de um efluente industrial aquecido sobre a comunidade zooplanctônica. O presente estudo teve como principal objetivo analisar os dados gerados por este monitoramento observando a variabilidade interanual ambiental e da comunidade zooplanctônica ao longo de dez anos de amostragens. Os resultados obtidos indicaram uma clara distinção entre o ponto amostral sob influência direta do efluente industrial, que apresentou média térmica da água superior em 2oC aos demais sítios amostrais. A comunidade zooplanctônica também apresentou variação espacial expressiva em densidade e diversidade, com menores densidades nas áreas mais próximas do descarte industrial e maior diversidade junto à porção mais costeira e sob influência direta do efluente. Com relação aos copépodos, táxons mais representativos da comunidade zooplanctônica, os resultados sugerem que os gêneros Acartia, Paracalanus e Temora podem representar importantes sinalizadores de variabilidade ecossistêmica de longo prazo em águas costeiras. Esses copépodos apresentaram uma variabilidade espacial em suas populações, consistentes com as diferenças ambientais observadas nos sítios amostrais, especialmente naqueles sob maior influência do efluente aquecido. Coletivamente, essas respostas indicam que embora a composição de espécies possa permanecer constante ao longo dos anos, os padrões de abundância são muito mais variáveis e mais afetados pelas alterações ambientais, apenas perceptíveis quando analisadas em larga escala temporal. In the last decade (1998-2007) collections were made of biotic (zooplankton) and abiotic (temperature and salinity) in the coastal waters adjacent to Praia Mole, in the Espírito Santo, in order to monitor the potential effects of disposal a heated effluent on the zooplankton community. This study aimed to analyze the data generated by this monitoring by observing the environment and interannual variability of zooplankton community over ten years of sampling. The results indicated a clear distinction between the sample point under the direct influence of industrial effluent, which showed higher average temperature of the water at 2°C to the other sites sampled. The zooplankton community also showed significant spatial variation in density and diversity, with lower values recorded in the areas farthest to the disposal industry. With respect to copepods, the most representative taxa of the zooplankton community, results suggest that the genera Acartia, Temora and Paracalanus flags can represent important long-term ecosystem variability in coastal waters. These copepods showed a spatial variability in their populations, consistent with the observed differences in environmental sampling sites, especially those under greater influence of the heated effluent. Collectively, these responses indicate that although species composition may remain constant over the years, the abundance patterns are much more variable and affected by environmental change, only noticeable when viewed on a large timescale.
- Published
- 2010
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.