1. Foley catheter with noble metal alloy coating for preventing catheter-associated urinary tract infections: a large, multi-center clinical trial
- Author
-
Ylva Kai-Larsen, Stefan Grass, Bhaumik Mody, Swati Upadhyay, Hargovind L. Trivedi, Dilip. K. Pal, Santosh Babu, Bikash Bawari, and Shrawan. K. Singh
- Subjects
Catheter ,Catheter-associated urinary tract infection ,Foley ,BIP foley catheter ,Noble metal alloy ,Coating ,Infectious and parasitic diseases ,RC109-216 - Abstract
Abstract Background Catheter-associated urinary tract infections (CAUTI) are among the most frequent healthcare-associated infections in the world. They are associated with increased mortality, prolonged hospital stay and increased healthcare costs. The objective of this study was to evaluate the efficacy of the noble metal alloy (NMA) coated BIP Foley Catheter in preventing the incidence of symptomatic CAUTI in a large cohort of patients in India. Methods This multi-center, prospective study included 1000 adult patients admitted to six hospitals across India for urology, surgery and ICU requiring urethral catheterization and admission for ≥ 48 h. Patients were allocated to the NMA-coated BIP Foley Catheter group or a non-coated control catheter group, with a randomization ratio of 3:1. CAUTI surveillance was conducted at study entry, upon catheter removal, and 2 days after catheter removal. For statistical analysis, categorical data (e.g. gender) were compared using the chi-square or Fischer test, and numerical data were compared using the two-sample t-test. Associations were evaluated using logistic regression. Results and conclusions The incidence of symptomatic CAUTI was reduced by 69% in the BIP Foley Catheter group compared to the control group (6.5 vs 20.8 CAUTI/1000 catheter days), with an incidence rate ratio of 0.31 (95% confidence interval: 0.21–0.46; p
- Published
- 2021
- Full Text
- View/download PDF