8 results on '"Miljoen HP"'
Search Results
2. Prospective Study of Tricuspid Regurgitation Associated With Permanent Leads After Cardiac Rhythm Device Implantation.
- Author
-
Van De Heyning CM, Elbarasi E, Masiero S, Brambatti M, Ghazal S, Al-Maashani S, Capucci A, Leong D, Shivalkar B, Saenen JB, Miljoen HP, Morillo CA, Divarakarmenon S, Amit G, Ribas S, Baiocco E, Maolo A, Romandini A, Maffei S, Connolly SJ, Healey JS, and Dokainish H
- Subjects
- Aged, Canada epidemiology, Disease Progression, Echocardiography, Female, Heart Atria diagnostic imaging, Humans, Male, Multivariate Analysis, Prevalence, Prospective Studies, Severity of Illness Index, Stroke Volume, Tricuspid Valve Insufficiency classification, Cardiac Resynchronization Therapy, Defibrillators, Implantable, Pacemaker, Artificial, Tricuspid Valve Insufficiency epidemiology
- Abstract
Background: Tricuspid regurgitation (TR) has been associated with cardiac rhythm device (CRD) implantation with intracardiac lead insertion. However, data on the incidence of postdevice TR are limited and largely from retrospective studies. We hypothesized that permanent lead implantation would be associated with an increase in TR., Methods: We prospectively included consecutive patients with a clinical indication for CRD. Patients underwent transthoracic echocardiography 1 month before and 1 year after CRD implantation., Results: A total of 328 patients were prospectively enrolled (69 ± 15 years, 38% female). Echocardiograms before and 1 year after CRD were available in 290 patients (15 died, 23 lost to follow-up). Compared with baseline, there was a significant change in TR grade 1 year after CRD insertion (no/trivial TR: 66% vs 29%; mild TR: 29% vs 61%; moderate TR: 3% vs 8%; severe TR 2% vs 2%; P < 0.001 for an increase in TR by at least 1 grade). Compared with baseline, there was a higher prevalence of moderate or severe TR in the 247 patients with CRD without cardiac resynchronization therapy (4% vs 10%, P = 0.004), but no progression in the 43 patients who received cardiac resynchronization therapy (14% vs 11%, P = 1). Multivariable analysis in the patients with less than moderate TR at baseline (n = 274) showed that only a history of atrial fibrillation was independently associated with progression to moderate or severe TR after correction for baseline TR grade (P = 0.013)., Conclusions: One year after endocardial lead insertion, there was a 5% increase in the prevalence of moderate or severe TR, which may be clinically relevant., (Copyright © 2018 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.)
- Published
- 2019
- Full Text
- View/download PDF
3. Superior efficacy of pulmonary vein isolation with online contact force measurement persists after the learning period: a prospective case control study.
- Author
-
Wolf M, Saenen JB, Bories W, Miljoen HP, Nullens S, Vrints CJ, and Sarkozy A
- Subjects
- Aged, Female, Humans, Learning Curve, Male, Middle Aged, Online Systems, Stress, Mechanical, Treatment Outcome, Atrial Fibrillation diagnosis, Atrial Fibrillation surgery, Catheter Ablation methods, Heart Conduction System surgery, Monitoring, Intraoperative methods, Pulmonary Veins surgery
- Abstract
Purpose: Use of online contact force (CF) measurement during circumferential pulmonary vein (PV) isolation (CPVI) for atrial fibrillation (AF) has demonstrated improvements in procedural parameters and mid-term clinical outcome. However, it is unknown if experience gained with CF measuring catheters improves the efficacy of subsequent CPVI procedures performed without CF measurement., Methods: This prospective trial compared procedural results of CPVI performed without a CF measuring catheter to a control group performed with a CF measuring catheter, by an operator with prior experience with CF technology.., Results: Thirty-six eligible paroxysmal (n = 27) or persistent (n = 9) AF patients were consecutively enrolled. Twelve patients underwent CPVI with the non-CF catheter (CF- group) in a recall period and 24 with the CF catheter (CF+ group). After the first circumferential lesion set, the number of PV pairs requiring additional touch-up lesions to achieve electrical isolation was significantly less in the CF+ group (2 of 48 (4.2 %) vs. 7 of 24 (29.2 %) in the CF+ and CF- groups, respectively, p = 0.005). The procedure time was significantly lower in the CF+ group (117.9 ± 23.3 vs. 134.1 ± 25.3 min, p = 0.033). Radiofrequency (RF) and fluoroscopy time did not differ between groups (31.5 ± 7.1 vs. 31.8 ± 7.0 min and 11.8 ± 5.6 vs. 11.0 ± 5.8 min in the CF+ and the CF- group, respectively), Conclusions: With the use of online CF measurement, PV isolation is more frequently complete following the first circumferential lesion set. A previous learning period with direct CF feedback is not a substitute for real-time direct CF measurement to maintain this advantage.
- Published
- 2015
- Full Text
- View/download PDF
4. Levels of circulating CD34+/KDR+ cells do not predict coronary in-stent restenosis.
- Author
-
Haine SE, Van Craenenbroeck EM, Hoymans VY, Miljoen HP, Vandendriessche TR, Claeys MJ, Frederix G, Conraads VM, Bosmans JM, and Vrints CJ
- Subjects
- Aged, Antigens, CD34 immunology, Cell Count, Coronary Angiography, Coronary Restenosis diagnosis, Coronary Restenosis immunology, Endothelial Cells pathology, Endothelium, Vascular immunology, Endothelium, Vascular metabolism, Endothelium, Vascular pathology, Female, Flow Cytometry, Follow-Up Studies, Humans, Male, Middle Aged, Predictive Value of Tests, Prosthesis Failure, Ultrasonography, Interventional, Antigens, CD34 blood, Coronary Restenosis blood, Endothelial Cells immunology, Stents, Vascular Endothelial Growth Factor Receptor-2 blood
- Abstract
Background: Angiographic and clinical parameters are poor predictors of in-stent restenosis. Bone marrow-derived CD34(+) cells that coexpress a receptor for vascular endothelial growth factor (kinase insert domain receptor [KDR]) are committed to endothelial lineage. Mobilization and infusion of CD34(+)/KDR(+) cells accelerates re-endothelialization and reduces neointimal thickness in vascular injury models. Bioengineered stents capturing CD34(+) cells also show expedited re-endothelialization. We examined whether circulating CD34(+)/KDR(+) cell counts can be used to predict restenosis in a bare-metal stent (BMS)., Methods: CD34(+)/KDR(+) cells were counted by flow cytometry in 124 nondiabetic patients before BMS implantation and the relation to in-stent late luminal loss (LLL) was examined by angiography at 6 months (primary end point). Neointima was also quantified as the maximum percentage area stenosis (M%AS) and percentage volume intima hyperplasia (%VIH) on intravascular ultrasonography (secondary end points)., Results: Multiple linear regression analysis, taking into account implanted stent length and diameter, revealed no relation between CD34(+)/KDR(+) cell counts and LLL (partial regression coefficient b = 0.11; 95% confidence interval [CI], -0.19-0.42; P = 0.46). Similarly, no relation between CD34(+)/KDR(+) cell counts and M%AS or %VIH could be demonstrated. Moreover, the increase in CD34(+)/KDR(+) cell counts over 6 months was unrelated to LLL (b = -0.15; 95% CI, -0.42-0.12; P = 0.28), M%AS, and %VIH., Conclusions: Although our study does not exclude a pathophysiologic role for CD34(+)/KDR(+) cells in the formation of neointima, cell counts before percutaneous coronary intervention proved to be unrelated to LLL or intravascular ultrasonographically derived restenosis parameters in coronary BMSs at 6 months., (Copyright © 2014 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.)
- Published
- 2014
- Full Text
- View/download PDF
5. Difference in clinical target lesion revascularization between a silicon carbide-coated and an uncoated thin strut bare-metal stent: the PRO-Vision study.
- Author
-
Haine SE, Cornez BM, Jacobs JM, Miljoen HP, Vandendriessche TR, Claeys MJ, Bosmans JM, and Vrints CJ
- Subjects
- Aged, Coronary Restenosis, Female, Humans, Male, Middle Aged, Treatment Outcome, Carbon Compounds, Inorganic, Coated Materials, Biocompatible, Coronary Artery Disease therapy, Percutaneous Coronary Intervention methods, Silicon Compounds, Stents
- Abstract
Background: Bare-metal stents trigger a foreign body reaction, resulting in neointima formation and restenosis. Silicon carbide (SiC) coating shields the metal from circulating blood and vessel wall, both potential sources of neointima smooth muscle cells., Methods: We investigated whether SiC-coated stents (PRO-Kinetic) have lower clinical target lesion revascularization (TLR) rates than do uncoated bare-metal stents (Vision). Stents were implanted in 2731 patients during 2 consecutive 18-month periods. Clinical TLR was evaluated at 1 year., Results: In the PRO-Kinetic group, TLR was significantly higher (9.0% vs 5.6%; unadjusted odds ratio, 1.61; 95% confidence interval [CI], 1.24-2.08; P < 0.001) compared with the Vision group. After adjustment for postintervention minimal luminal diameter (adjusted odds ratio [AOR], 0.56; 95% CI, 0.42-0.73), total implanted stent length (AOR, 1.01; 95% CI, 1.00-1.02), non-ST-segment elevation myocardial infarction or unstable angina at initial presentation (AOR, 1.89; 95% CI, 1.41-2.54), and triple vessel stenting (AOR, 2.68; 95% CI, 1.02-7.05), the use of PRO-Kinetic stents remained an independent predictor for revascularization (AOR, 1.57; 95% CI, 1.18-2.10; P = 0.002). Because strut thickness is lower in 2.0- to 3.0-mm PRO-Kinetic stents, a subgroup analysis (n = 2382 lesions) was performed. Even in this subgroup, PRO-Kinetic implantation proved an independent predictor of TLR (AOR, 1.62; 95% CI, 1.17-2.23; P = 0.003)., Conclusion: In contrast to theoretical expectations, the SiC-coated PRO-Kinetic stent was associated with greater target lesion revascularization rates at 1 year compared with the uncoated Vision stent., (Copyright © 2013 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.)
- Published
- 2013
- Full Text
- View/download PDF
6. Atrioventricular dissociation due to pheochromocytoma in a young adult.
- Author
-
Haine SE, Miljoen HP, Blankoff I, and Vrints CJ
- Subjects
- Adrenal Gland Neoplasms diagnosis, Adrenal Gland Neoplasms surgery, Adrenalectomy, Adult, Atrioventricular Block diagnosis, Atrioventricular Block therapy, Cardiac Pacing, Artificial, Electrocardiography, Electrophysiologic Techniques, Cardiac, Female, Humans, Pacemaker, Artificial, Pheochromocytoma diagnosis, Pheochromocytoma surgery, Tachycardia, Supraventricular diagnosis, Tachycardia, Supraventricular therapy, Treatment Outcome, Unnecessary Procedures, Adrenal Gland Neoplasms complications, Atrioventricular Block etiology, Pheochromocytoma complications, Tachycardia, Supraventricular etiology
- Abstract
Atrioventricular dissociation can be a manifestation of an underlying noncardiac disease.We present a patient who underwent pacemaker implantation because of intermittent atrioventricular dissociation and medically untreatable supraventricular arrhythmias, which could not be induced by electrophysiological testing. The arrhythmias proved to be due to a pheochromocytoma. After left adrenalectomy, both the supraventricular arrhythmias and the atrioventricular dissociation disappeared. Adequate recognition and treatment of pheochromocytoma can reverse atrioventricular dissociation and may avoid unnecessary procedures such as electrophysiological testing and pacemaker implantation., (Copyright © 2010 Wiley Periodicals, Inc.)
- Published
- 2010
- Full Text
- View/download PDF
7. Mianserin and ventricular tachycardia: case report and review of the literature.
- Author
-
Haine SE, Miljoen HP, Blankoff I, and Vrints CJ
- Subjects
- Adult, Electrocardiography, Humans, Male, Tachycardia, Ventricular diagnosis, Antidepressive Agents, Second-Generation adverse effects, Mianserin adverse effects, Tachycardia, Ventricular chemically induced
- Abstract
Mianserin is a drug frequently used to treat depression and sleep disturbances. Despite documented effects on various cardiac tissues in animal studies, mianserin has a very safe clinical profile. Only one case of ventricular arrhythmias in a patient treated with mianserin has been reported. This patient had a severe cardiac history. Our case is to our knowledge the first report on ventricular arrhythmias in a patient treated with mianserin without previous or present cardiac disease. After discontinuation of mianserin the arrhythmias disappeared within days. The literature on mianserin toxicity is reviewed., (2006 S. Karger AG, Basel)
- Published
- 2006
- Full Text
- View/download PDF
8. Anti-glomerular basement membrane glomerulopathy in a young child.
- Author
-
Boven K, Miljoen HP, Van Hoeck KJ, Van Marck EA, and Van Acker KJ
- Subjects
- Basement Membrane immunology, Child, Preschool, Female, Fluorescent Antibody Technique, Indirect, Glomerulonephritis, Membranous drug therapy, Glomerulonephritis, Membranous immunology, Humans, Immunosuppressive Agents therapeutic use, Kidney pathology, Glomerulonephritis, Membranous pathology
- Abstract
We report the youngest patient with anti-glomerular basement membrane disease described in the literature to date. Age-dependent expression of the target antigen in this auto-immune disease explains the low incidence in young children. Despite adequate immunosuppression, renal function did not recover in our patient.
- Published
- 1996
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.