Back to Search Start Over

Superior efficacy of pulmonary vein isolation with online contact force measurement persists after the learning period: a prospective case control study.

Authors :
Wolf M
Saenen JB
Bories W
Miljoen HP
Nullens S
Vrints CJ
Sarkozy A
Source :
Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing [J Interv Card Electrophysiol] 2015 Sep; Vol. 43 (3), pp. 287-96. Date of Electronic Publication: 2015 May 09.
Publication Year :
2015

Abstract

Purpose: Use of online contact force (CF) measurement during circumferential pulmonary vein (PV) isolation (CPVI) for atrial fibrillation (AF) has demonstrated improvements in procedural parameters and mid-term clinical outcome. However, it is unknown if experience gained with CF measuring catheters improves the efficacy of subsequent CPVI procedures performed without CF measurement.<br />Methods: This prospective trial compared procedural results of CPVI performed without a CF measuring catheter to a control group performed with a CF measuring catheter, by an operator with prior experience with CF technology..<br />Results: Thirty-six eligible paroxysmal (n = 27) or persistent (n = 9) AF patients were consecutively enrolled. Twelve patients underwent CPVI with the non-CF catheter (CF- group) in a recall period and 24 with the CF catheter (CF+ group). After the first circumferential lesion set, the number of PV pairs requiring additional touch-up lesions to achieve electrical isolation was significantly less in the CF+ group (2 of 48 (4.2 %) vs. 7 of 24 (29.2 %) in the CF+ and CF- groups, respectively, p = 0.005). The procedure time was significantly lower in the CF+ group (117.9 ± 23.3 vs. 134.1 ± 25.3 min, p = 0.033). Radiofrequency (RF) and fluoroscopy time did not differ between groups (31.5 ± 7.1 vs. 31.8 ± 7.0 min and 11.8 ± 5.6 vs. 11.0 ± 5.8 min in the CF+ and the CF- group, respectively)<br />Conclusions: With the use of online CF measurement, PV isolation is more frequently complete following the first circumferential lesion set. A previous learning period with direct CF feedback is not a substitute for real-time direct CF measurement to maintain this advantage.

Details

Language :
English
ISSN :
1572-8595
Volume :
43
Issue :
3
Database :
MEDLINE
Journal :
Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing
Publication Type :
Academic Journal
Accession number :
25956480
Full Text :
https://doi.org/10.1007/s10840-015-0006-4