1. Modal Testing and Analysis of High-rise Laminated Timber Building
- Author
-
Qiyun Xu, Hongyan Zou, Zheng Wang, Yuhang He, Liang Qi, and Jun Wang
- Subjects
laminated timber ,natural frequency ,dynamic characteristics ,calculating modal ,experimental modal ,Biotechnology ,TP248.13-248.65 - Abstract
To enhance the design and research work on dynamic characteristics of high-rise laminated timber buildings, this paper carried out a modal analysis study on one of the largest laminated timber buildings in China. The finite element calculating modal analysis was carried out using SAP2000 software, and the experimental modal analysis of the building was carried out via environmental excitation. The calculating modal results and the experimental modal results showed good agreement. The calculating modal frequency values were generally lower than the experimental modal frequency values. The natural frequencies obtained by the two methods appeared in the Y-direction first-order bending mode and had values of 2.03 and 2.5 Hz, respectively. The corresponding frequencies of the first-order torsional mode were 2.82 and 3.25 Hz, respectively. The distribution of the CLT core tube along the length direction of the building has an impact on the vibration mode. The six-story part shows the second-order bending form, while the four-story section only shows the first-order bending form. The above work provides a case study and reference for the simulation and modal analysis of high-rise laminated timber buildings, demonstrating the critical role of the core tube structure in such wooden buildings. This insight contributes to a better understanding of structural performance and design considerations in similar projects.
- Published
- 2024