1. Comparison of exsanguination and hemostasis devices for Limb surgery: a multicenter randomized controlled study.
- Author
-
Xu J, Zhao K, Xu S, Xu J, Sun B, Tong S, Yao W, Bi Q, Yang Z, and Zhou W
- Subjects
- Humans, Female, Male, Middle Aged, Adult, Extremities surgery, Hemostasis, Surgical instrumentation, Hemostasis, Surgical methods, Aged, Treatment Outcome, Prospective Studies, Blood Loss, Surgical prevention & control, Tourniquets adverse effects, Exsanguination etiology
- Abstract
Background: Excessive intraoperative bleeding remains a challenge in limb surgeries. The exsanguination tourniquet ring has emerged as a potential solution for effective exsanguination and hemostasis. This study aims to evaluate its efficacy and safety compared to the conventional exsanguination and hemostasis approach (pneumatic tourniquet combined with Esmarch bandage)., Methods: This randomized controlled trial evaluates the exsanguination tourniquet ring's effectiveness and safety versus the conventional approach in 220 participants undergoing various limb surgeries. Allocation included experimental and control groups, assesses through efficacy (including intraoperative and total blood loss, hemoglobin levels, and exsanguination and hemostasis effectiveness) and safety (adverse event occurrence) indicators., Results: The experimental group (n = 110) utilizes the exsanguination tourniquet ring, while the control group (n = 110) employs the conventional approach. As for intraoperative blood loss, the experimental group is non-inferior to the control group (p-value < 0.001). While no significant difference is found in total blood loss (for the full analysis set, p-value = 0.442; for the per protocol set, p-value = 0.976) and differences in postoperative and preoperative hemoglobin levels (for the full analysis set, p-value = 0.502; for the per protocol set, p-value = 0.928). Regarding exsanguination and hemostasis effectiveness, the full analysis set reveals significantly superior ratings in the experimental group compared to the control group (p-value = 0.002 < 0.05), while the per protocol set analysis indicates no significant difference between the groups (p-value = 0.504). As for safety indicators, adverse events related to the device are minimal in two groups, with only one severe event unrelated to the device., Conclusions: The exsanguination tourniquet ring is an effective and safe device for intraoperative blood loss control in various limb surgeries., Trial Registration: Comparison of Exsanguination and Hemostasis Devices for Limb Surgery A Prospective Multicenter Randomized Controlled Study, ChiCTR2300077998, 11/27/2023., (© 2024. The Author(s).)
- Published
- 2024
- Full Text
- View/download PDF