1. MEASUREMENT OF INTRAOCULAR PRESSURE IN THE DOMESTIC PIGEON (COLUMBIA LIVIA).
- Author
-
Ansari Mood M, Rajaei SM, Hashemi SS, and Williams DL
- Subjects
- Animals, Female, Male, Tonometry, Ocular instrumentation, Tonometry, Ocular methods, Columbidae physiology, Intraocular Pressure physiology, Tonometry, Ocular veterinary
- Abstract
The purpose of this study was to establish intraocular pressure values in clinically normal pigeons. One hundred (52 male and 48 female) healthy pigeons ( Columbia livia ) of six different breeds, ranging in age from 20 to 51 mo were used in the study. Pigeons were gently physically restrained in a dorsoventral position without any pressure or extension to the head and neck. A rebound tonometer with a disposable probe was held horizontally and 4-5 mm from the central corneal surface. Calibration of the device was set to "P." Overall, the mean ± SD intraocular pressure values of all eyes were 6.1 ± 0.9 mmHg (ranging from 3 to 9 mmHg). Mean ± SD values for left and right eyes were 6.1 ± 1.0 and 6.0 ± 1.2 mmHg, respectively. There was no statistically significant difference in IOP between the left eye and right eye or between males and females (P = 0.49; P = 0.74). Analysis of variance revealed that there were no significant differences in the IOP between the breeds (P = 0.22).
- Published
- 2016
- Full Text
- View/download PDF