1. Comparison of Prostate Imaging and Reporting Data System V2.0 and V2.1 for Evaluation of Transition Zone Lesions: A 5-Reader 202-Patient Analysis.
- Author
-
Kim N, Kim S, Prabhu V, Shanbhogue K, Smereka P, Tong A, Anthopolos R, Taneja SS, and Rosenkrantz AB
- Subjects
- Humans, Magnetic Resonance Imaging methods, Male, Neoplasm Grading, Retrospective Studies, Prostate diagnostic imaging, Prostate pathology, Prostatic Neoplasms diagnostic imaging, Prostatic Neoplasms pathology
- Abstract
Objective: The aim of the study was to compare the distribution of Prostate Imaging and Reporting Data System (PI-RADS) scores, interreader agreement, and diagnostic performance of PI-RADS v2.0 and v2.1 for transition zone (TZ) lesions., Methods: The study included 202 lesions in 202 patients who underwent 3T prostate magnetic resonance imaging showing a TZ lesion that was later biopsied with magnetic resonance imaging/ultrasound fusion. Five abdominal imaging faculty reviewed T2-weighted imaging and high b value/apparent diffusion coefficient images in 2 sessions. Cases were randomized using a crossover design whereby half in the first session were reviewed using v2.0 and the other half using v2.1, and vice versa for the 2nd session. Readers provided T2-weighted imaging and DWI scores, from which PI-RADS scores were derived., Results: Interreader agreement for all PI-RADS scores had κ of 0.37 (v2.0) and 0.26 (v2.1). For 4 readers, the percentage of lesions retrospectively scored PI-RADS 1 increased greater than 5% and PI-RADS 2 score decreased greater than 5% from v2.0 to v2.1. For 2 readers, the percentage scored PI-RADS 3 decreased greater than 5% and, for 2 readers, increased greater than 5%. The percentage of PI-RADS 4 and 5 lesions changed less than 5% for all readers. For the 4 readers with increased frequency of PI-RADS 1 using v2.1, 4% to 16% were Gleason score ≥3 + 4 tumor. Frequency of Gleason score ≥3 + 4 in PI-RADS 3 lesions increased for 2 readers and decreased for 1 reader. Sensitivity of PI-RADS of 3 or greater for Gleason score ≥3 + 4 ranged 76% to 90% (v2.0) and 69% to 96% (v2.1). Specificity ranged 32% to 64% (v2.0) and 25% to 72% (v2.1). Positive predictive value ranged 43% to 55% (v2.0) and 41% to 58% (v2.1). Negative predictive value ranged 82% to 87% (v2.0) and 81% to 91% (v2.1)., Conclusions: Poor interreader agreement and lack of improvement in diagnostic performance indicate an ongoing need to refine evaluation of TZ lesions., Competing Interests: A.B.R. received royalties from Thieme Medical Publishers and salary support for AJR editorship. The other authors declare no conflict of interest., (Copyright © 2022 Wolters Kluwer Health, Inc. All rights reserved.)
- Published
- 2022
- Full Text
- View/download PDF