1. Analysis on the accuracy of CT-guided radioactive I-125 seed implantation with 3D printing template assistance in the treatment of thoracic malignant tumors.
- Author
-
Ji Z, Sun H, Jiang Y, Chen Y, Guo F, Fan J, and Wang J
- Subjects
- Adult, Aged, Brachytherapy instrumentation, Female, Humans, Iodine Radioisotopes administration & dosage, Male, Middle Aged, Needles, Radiotherapy Planning, Computer-Assisted, Thoracic Neoplasms diagnostic imaging, Young Adult, Brachytherapy methods, Iodine Radioisotopes therapeutic use, Printing, Three-Dimensional, Radiography, Interventional methods, Thoracic Neoplasms radiotherapy, Tomography, X-Ray Computed
- Abstract
This article analyzes the accuracy of needle track and dose of a 3-dimensional printing template (3DPT) in the treatment of thoracic tumor with radioactive I-125 seed implantation (RISI). A total of 28 patients were included. The technical process included: (i) preoperative CT positioning, (ii) preoperative planning design, (iii) 3DPT design and printing, (iv) 3DPT alignment, (v) puncture and seed implantation. The errors of needle position and dosimetric parameters were analyzed. A total of 318 needles were used. The mean errors in needle depth, needle insertion point, needle tip and needle angle were 0.52 ± 0.48 cm, 3.4 ± 1.7 mm, 4.4 ± 2.9 mm and 2.8 ± 1.7°, respectively. The differences between actual needle insertion angle and needle depth and those designed in the preoperative were statistically significant (p < 0.05). The mean values of all the errors of the chest wall cases were smaller than those of the lungs, and the differences were statistically significant (p < 0.05). There was no significant difference between the D90 calculated in the postoperative plan and those designed in the preoperative and intraoperative plans (p > 0.05). Some dosimetric parameters of preoperative plans such as V100, V200, CI and HI were not consistent with that of preoperative plans, and the difference was statistically significant (p < 0.05). However, there were no statistical difference in the dosimetric parameters between the postoperative plans and intraoperative plans (p > 0.05). We conclude that for thoracic tumors, even under the guidance of 3DPT, there will be errors. The plan should be optimized in real time during the operation., (© The Author(s) 2021. Published by Oxford University Press on behalf of The Japanese Radiation Research Society and Japanese Society for Radiation Oncology.)
- Published
- 2021
- Full Text
- View/download PDF