Back to Search
Start Over
Analysis on the accuracy of CT-guided radioactive I-125 seed implantation with 3D printing template assistance in the treatment of thoracic malignant tumors.
- Source :
-
Journal of radiation research [J Radiat Res] 2021 Sep 13; Vol. 62 (5), pp. 910-917. - Publication Year :
- 2021
-
Abstract
- This article analyzes the accuracy of needle track and dose of a 3-dimensional printing template (3DPT) in the treatment of thoracic tumor with radioactive I-125 seed implantation (RISI). A total of 28 patients were included. The technical process included: (i) preoperative CT positioning, (ii) preoperative planning design, (iii) 3DPT design and printing, (iv) 3DPT alignment, (v) puncture and seed implantation. The errors of needle position and dosimetric parameters were analyzed. A total of 318 needles were used. The mean errors in needle depth, needle insertion point, needle tip and needle angle were 0.52 ± 0.48 cm, 3.4 ± 1.7 mm, 4.4 ± 2.9 mm and 2.8 ± 1.7°, respectively. The differences between actual needle insertion angle and needle depth and those designed in the preoperative were statistically significant (p < 0.05). The mean values of all the errors of the chest wall cases were smaller than those of the lungs, and the differences were statistically significant (p < 0.05). There was no significant difference between the D90 calculated in the postoperative plan and those designed in the preoperative and intraoperative plans (p > 0.05). Some dosimetric parameters of preoperative plans such as V100, V200, CI and HI were not consistent with that of preoperative plans, and the difference was statistically significant (p < 0.05). However, there were no statistical difference in the dosimetric parameters between the postoperative plans and intraoperative plans (p > 0.05). We conclude that for thoracic tumors, even under the guidance of 3DPT, there will be errors. The plan should be optimized in real time during the operation.<br /> (© The Author(s) 2021. Published by Oxford University Press on behalf of The Japanese Radiation Research Society and Japanese Society for Radiation Oncology.)
- Subjects :
- Adult
Aged
Brachytherapy instrumentation
Female
Humans
Iodine Radioisotopes administration & dosage
Male
Middle Aged
Needles
Radiotherapy Planning, Computer-Assisted
Thoracic Neoplasms diagnostic imaging
Young Adult
Brachytherapy methods
Iodine Radioisotopes therapeutic use
Printing, Three-Dimensional
Radiography, Interventional methods
Thoracic Neoplasms radiotherapy
Tomography, X-Ray Computed
Subjects
Details
- Language :
- English
- ISSN :
- 1349-9157
- Volume :
- 62
- Issue :
- 5
- Database :
- MEDLINE
- Journal :
- Journal of radiation research
- Publication Type :
- Academic Journal
- Accession number :
- 34350955
- Full Text :
- https://doi.org/10.1093/jrr/rrab068