1. Comprehensive Consideration on AMR Configuration for Magnetocaloric Heat Pump
- Author
-
Tsuyoshi Kawanami, Didier Vuarnoz, Shigeki Hirano, and Atsuya Toba
- Subjects
Coupling ,Pressure drop ,Materials science ,magneto-caloric effect ,Thermodynamics ,Mechanics ,numerical simulatio ,law.invention ,Energy conservation ,heat pump ,law ,Regenerative heat exchanger ,Magnetic refrigeration ,Working fluid ,Thermal model ,active magnetic regenerator ,Heat pump - Abstract
This paper discusses the system performance of a magnetic heat pump with an active magnetic regenerator. The heat-transfer coefficient and pressure drop in the AMR are performed analytically. Measurements on the experimental magnetic heat pump test device are performed using distilled water as the working fluid. The coupling of a one-dimensional thermal model is presented. The thermal model takes into consideration the magneto-caloric effect as a source term and the energy conservation between a solid and a fluid. At cyclic steady states, the temperatures of the fluid on both sides of the regenerator are calculated numerically and compared with the measurement results. A reasonable agreement between simulations and experiments confirms the validity of the proposed model.
- Published
- 2015
- Full Text
- View/download PDF