Back to Search Start Over

Comprehensive Consideration on AMR Configuration for Magnetocaloric Heat Pump

Authors :
Tsuyoshi Kawanami
Didier Vuarnoz
Shigeki Hirano
Atsuya Toba
Source :
TEION KOGAKU (Journal of Cryogenics and Superconductivity Society of Japan). 50:72-79
Publication Year :
2015
Publisher :
Cryogenic Association of Japan, 2015.

Abstract

This paper discusses the system performance of a magnetic heat pump with an active magnetic regenerator. The heat-transfer coefficient and pressure drop in the AMR are performed analytically. Measurements on the experimental magnetic heat pump test device are performed using distilled water as the working fluid. The coupling of a one-dimensional thermal model is presented. The thermal model takes into consideration the magneto-caloric effect as a source term and the energy conservation between a solid and a fluid. At cyclic steady states, the temperatures of the fluid on both sides of the regenerator are calculated numerically and compared with the measurement results. A reasonable agreement between simulations and experiments confirms the validity of the proposed model.

Details

ISSN :
18800408 and 03892441
Volume :
50
Database :
OpenAIRE
Journal :
TEION KOGAKU (Journal of Cryogenics and Superconductivity Society of Japan)
Accession number :
edsair.doi.dedup.....a4f018021d70e68127faabd7abfa5201
Full Text :
https://doi.org/10.2221/jcsj.50.72