15 results on '"Charitos EI"'
Search Results
2. Long-Term Outcomes of Patients Undergoing the Ross Procedure.
- Author
-
Aboud A, Charitos EI, Fujita B, Stierle U, Reil JC, Voth V, Liebrich M, Andreas M, Holubec T, Bening C, Albert M, Fila P, Ondrasek J, Murin P, Lange R, Reichenspurner H, Franke U, Gorski A, Moritz A, Laufer G, Hemmer W, Sievers HH, and Ensminger S
- Subjects
- Adult, Echocardiography methods, Female, Germany epidemiology, Heart Valve Prosthesis adverse effects, Heart Valve Prosthesis statistics & numerical data, Humans, Male, Prognosis, Registries statistics & numerical data, Risk Assessment methods, Risk Factors, Survival Analysis, Treatment Outcome, Aortic Valve pathology, Aortic Valve surgery, Aortic Valve Disease diagnosis, Aortic Valve Disease epidemiology, Aortic Valve Disease surgery, Heart Valve Prosthesis Implantation adverse effects, Heart Valve Prosthesis Implantation instrumentation, Heart Valve Prosthesis Implantation methods, Long Term Adverse Effects diagnosis, Long Term Adverse Effects epidemiology, Long Term Adverse Effects etiology, Postoperative Complications diagnosis, Postoperative Complications epidemiology, Postoperative Complications etiology, Postoperative Complications surgery, Reoperation classification, Reoperation methods, Reoperation statistics & numerical data, Transplantation, Autologous adverse effects, Transplantation, Autologous methods
- Abstract
Background: Treatment of aortic-valve disease in young patients still poses challenges. The Ross procedure offers several potential advantages that may translate to improved long-term outcomes., Objectives: This study reports long-term outcomes after the Ross procedure., Methods: Adult patients who were included in the Ross Registry between 1988 and 2018 were analyzed. Endpoints were overall survival, reintervention, and major adverse events at maximum follow-up. Multivariable regression analyses were performed to identify risk factors for survival and the need of Ross-related reintervention., Results: There were 2,444 adult patients with a mean age of 44.1 ± 11.7 years identified. Early mortality was 1.0%. Estimated survival after 25 years was 75.8% and did not statistically differ from the general population (p = 0.189). The risk for autograft reintervention was 0.69% per patient-year and 0.62% per patient-year for right-ventricular outflow tract (RVOT) reintervention. Larger aortic annulus diameter (hazard ratio [HR]: 1.12/mm; 95% confidence interval [CI]: 1.05 to 1.19/mm; p < 0.001) and pre-operative presence of pure aortic insufficiency (HR: 1.74; 95% CI: 1.13 to 2.68; p = 0.01) were independent predictors for autograft reintervention, whereas the use of a biological valve (HR: 8.09; 95% CI: 5.01 to 13.08; p < 0.001) and patient age (HR: 0.97 per year; 95% CI: 0.96 to 0.99; p = 0.001) were independent predictors for RVOT reintervention. Major bleeding, valve thrombosis, permanent stroke, and endocarditis occurred with an incidence of 0.15% per patient-year, 0.07% per patient-year, 0.13%, and 0.36% per patient-year, respectively., Conclusions: The Ross procedure provides excellent survival over a follow-up period of up to 25 years. The rates of reintervention, anticoagulation-related morbidity, and endocarditis were very low. This procedure should therefore be considered as a very suitable treatment option in young patients suffering from aortic-valve disease. (Long-Term Follow-up After the Autograft Aortic Valve Procedure [Ross Operation]; NCT00708409)., Competing Interests: Funding Support and Author Disclosures The authors have reported that they have no relationships relevant to the contents of this paper to disclose., (Copyright © 2021 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.)
- Published
- 2021
- Full Text
- View/download PDF
3. NeoChord System as an Alternative Option Upon Transmitral Pressure Gradient Elevation in the MitraClip Procedure.
- Author
-
Sugiura A, Weber M, Charitos EI, Treede H, Sinning JM, and Nickenig G
- Subjects
- Aged, 80 and over, Clinical Decision-Making, Female, Heart Valve Prosthesis Implantation adverse effects, Humans, Mitral Valve Insufficiency diagnostic imaging, Mitral Valve Insufficiency physiopathology, Mitral Valve Prolapse diagnostic imaging, Mitral Valve Prolapse physiopathology, Prosthesis Design, Recovery of Function, Risk Factors, Severity of Illness Index, Treatment Outcome, Heart Valve Prosthesis, Heart Valve Prosthesis Implantation instrumentation, Hemodynamics, Mitral Valve Insufficiency surgery, Mitral Valve Prolapse surgery
- Published
- 2020
- Full Text
- View/download PDF
4. The role of transcatheter mitral valve therapy in heart failure.
- Author
-
Treede H and Charitos EI
- Subjects
- Humans, Mitral Valve Annuloplasty, Prostheses and Implants, Prosthesis Design, Heart Failure surgery, Heart Valve Prosthesis Implantation methods, Mitral Valve surgery, Mitral Valve Insufficiency surgery
- Abstract
Mitral valve regurgitation is detected in up to 75% of patients with heart failure. Interventional mitral valve therapies can be used to treat mitral regurgitation with very low morbidity and mortality rates and minimal invasiveness. Devices intended for the replacement of the mitral valve still require significant development and refinement before entering clinical practice on a large scale. The derived benefit of these therapies, the priority (repair over replacement) and the therapeutic role in patients with secondary mitral regurgitation due to heart failure remain to be investigated., (© The Author(s) 2019. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery.)
- Published
- 2019
- Full Text
- View/download PDF
5. Decellularized Versus Standard Pulmonary Allografts in the Ross Procedure: Propensity-Matched Analysis.
- Author
-
da Costa FDA, Etnel JRG, Charitos EI, Sievers HH, Stierle U, Fornazari D, Takkenberg JJM, Bogers AJJC, and Mokhles MM
- Subjects
- Adult, Cryopreservation, Female, Heart Ventricles surgery, Humans, Male, Propensity Score, Retrospective Studies, Treatment Outcome, Aortic Valve, Heart Valve Diseases surgery, Heart Valve Prosthesis Implantation methods, Pulmonary Valve transplantation, Tissue Transplantation methods
- Abstract
Background: It is hypothesized that decellularization of allografts used for right ventricular outflow tract reconstruction may result in decreased valve deterioration. This study compared the durability of fresh decellularized pulmonary allografts with standard cryopreserved pulmonary allografts in patients undergoing the Ross procedure., Methods: The Ross procedure was performed in 144 patients with decellularized allografts (DA) from 2005 to 2014 and in 619 with standard cryopreserved allografts (SCA) from 1990 to 2014. Propensity score matching was used to compare early and midterm clinical outcome and echocardiographic allograft function over time between the two groups., Results: We matched 94 DA patients (79.3% male; median age, 34.0 years; mean follow-up, 2.4 ± 1.9 years) to 94 SCA patients (78.3% male; median age, 35.0 years; mean follow-up, 9.4 ± 4.2 years). There were no significant differences in baseline characteristics after matching. The matched DA vs SCA groups, respectively, were comparable in actuarial 5-year freedom from allograft dysfunction (85.6% [95% confidence interval {CI}, 53.9% to 96.2%] vs 93.3% [95% CI, 85.7% to 96.9%], p = 0.892), freedom from allograft reintervention (98.8% [95% CI, 91.7% to 99.8%] vs 95.5% [95% CI, 88.5% to 98.3%], p = 0.383), survival (95.3% [95% CI, 87.8% to 98.2%] vs 97.7% [95% CI, 91.3% to 99.4%], p = 0.323), and event-free survival (83.5% [95% CI, 70.6% to 91.1%] vs 84.5% [95% CI, 75.2% to 90.5%], p = 0.515). Longitudinal echocardiographic analyses showed a similarly modest increase in allograft gradient and regurgitation grades over time in both groups, although direct statistical comparison was not possible., Conclusions: Up to 5 years of follow-up, DA and SCA used for right ventricular outflow tract reconstruction in the Ross procedure are associated with comparably excellent clinical and hemodynamic outcome. Longer follow-up and dedicated echocardiographic studies will shed light on the long-term performance of DAs., (Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.)
- Published
- 2018
- Full Text
- View/download PDF
6. Does Undersizing of Transcatheter Aortic Valve Bioprostheses during Valve-in-Valve Implantation Avoid Coronary Obstruction? An In Vitro Study.
- Author
-
Stock S, Scharfschwerdt M, Meyer-Saraei R, Richardt D, Charitos EI, Sievers HH, and Hanke T
- Subjects
- Aortic Valve physiopathology, Balloon Valvuloplasty, Coronary Circulation, Coronary Stenosis etiology, Coronary Stenosis physiopathology, Heart Valve Prosthesis Implantation adverse effects, Hemodynamics, Humans, Hydrodynamics, Materials Testing, Models, Anatomic, Models, Cardiovascular, Prosthesis Design, Risk Factors, Transcatheter Aortic Valve Replacement adverse effects, Aortic Valve surgery, Bioprosthesis, Coronary Stenosis prevention & control, Heart Valve Prosthesis, Heart Valve Prosthesis Implantation instrumentation, Prosthesis Failure, Transcatheter Aortic Valve Replacement instrumentation
- Abstract
Background The transcatheter aortic valve-in-valve implantation (TAViVI) is an evolving treatment strategy for degenerated surgical aortic valve bioprostheses (SAVBs) in patients with high operative risk. Although hemodynamics is excellent, there is some concern regarding coronary obstruction, especially in SAVB with externally mounted leaflet tissue, such as the Trifecta (St. Jude Medical Inc., St. Paul, Minnesota, United States). We investigated coronary flow and hydrodynamics before and after TAViVI in a SAVB with externally mounted leaflet tissue (St. Jude Medical, Trifecta) with an undersized transcatheter aortic valve bioprosthesis (Edwards Sapien XT; Edwards Lifesciences LLC, Irvine, California, United States) in an in vitro study. Materials and Methods An aortic root model was constructed incorporating geometric dimensions known as risk factors for coronary obstruction. Investigating the validity of this model, we primarily performed recommended TAViVI with the Sapien XT (size 26 mm) in a Trifecta (size 25 mm) in a mock circulation. Thereafter, hydrodynamic performance and coronary flow (left/right coronary diastolic flow [lCF/rCF]) after TAViVI with an undersized Sapien XT (size 23 mm) in a Trifecta (size 25 mm) were investigated at two different coronary ostia heights (COHs, 8 and 10 mm). Results Validation of the model led to significant coronary obstruction ( p < 0.001). Undersized TAViVI showed no significant reduction with respect to coronary flow (lCF: COH 8 mm, 0.90-0.87 mL/stroke; COH 10 mm, 0.89-0.82 mL/stroke and rCF: COH 8 mm, 0.64-0.60 mL/stroke; COH 10 mm, 0.62-0.58 mL/stroke). Mean transvalvular gradients (4-5 mm Hg, p < 0.001) increased significantly after TAViVI. Conclusions In our in vitro model, undersized TAViVI with the balloon-expandable Sapien XT into a modern generation SAVB (Trifecta) successfully avoided coronary flow obstruction., (Georg Thieme Verlag KG Stuttgart · New York.)
- Published
- 2017
- Full Text
- View/download PDF
7. Ross Procedure in Neonates and Infants: A European Multicenter Experience.
- Author
-
Mookhoek A, Charitos EI, Hazekamp MG, Bogers AJ, Hörer J, Lange R, Hetzer R, Sachweh JS, Riso A, Stierle U, Takkenberg JJ, and Schoof PH
- Subjects
- Aortic Valve abnormalities, Autografts, Echocardiography, Female, Follow-Up Studies, Germany, Humans, Infant, Newborn, Male, Netherlands, Retrospective Studies, Treatment Outcome, Ventricular Outflow Obstruction congenital, Ventricular Outflow Obstruction diagnostic imaging, Aortic Valve surgery, Cardiac Surgical Procedures methods, Heart Valve Prosthesis Implantation methods, Pulmonary Valve transplantation, Ventricular Outflow Obstruction surgery
- Abstract
Background: Infants and neonates with severe left ventricular outflow tract obstruction may require pulmonary autograft replacement of the aortic root. In this retrospective multicenter cohort study, we present our experience with the Ross procedure in neonates and infants with a focus on midterm survival and pulmonary autograft durability., Methods: A retrospective observational study was performed in 76 infants (aged less than 1 year) operated on in six congenital cardiac centers in The Netherlands and Germany between 1990 and 2013., Results: Patients had a pulmonary autograft replacement of the aortic valve with (68%) or without (32%) septal myectomy. Median patient age was 85 days (range, 6 to 347). Early mortality (n = 13, 17%) was associated with neonatal age, preoperative use of intravenous inotropic drugs, and congenital aortic arch defects. Five patients (9%) died during follow-up. Freedom from autograft reintervention was 98% at 10 years. Echocardiography demonstrated good valve function, with no or trace regurgitation in 73% of patients. Freedom from right ventricular outflow tract reintervention was 51% at 10 years. Univariable analysis demonstrated superior freedom from reintervention of pulmonary homografts compared with aortic homografts or xenografts., Conclusions: Pulmonary autograft replacement of the aortic valve in neonates and infants is a high-risk operation but offers a durable neoaortic valve. Midterm durability reflects successful adaptation of the autograft to the systemic circulation. Late mortality associated with heart failure was an unexpected finding., (Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.)
- Published
- 2015
- Full Text
- View/download PDF
8. European multicenter experience with valve-sparing reoperations after the Ross procedure.
- Author
-
Mookhoek A, de Kerchove L, El Khoury G, Weimar T, Luciani GB, Mazzucco A, Bogers AJ, Aicher D, Schäfers HJ, Charitos EI, Stierle U, and Takkenberg JJ
- Subjects
- Adolescent, Adult, Aorta physiopathology, Aortic Valve physiopathology, Aortic Valve Insufficiency diagnosis, Aortic Valve Insufficiency etiology, Aortic Valve Insufficiency mortality, Aortic Valve Insufficiency physiopathology, Blood Vessel Prosthesis Implantation adverse effects, Blood Vessel Prosthesis Implantation mortality, Disease-Free Survival, Europe, Female, Heart Valve Prosthesis Implantation adverse effects, Heart Valve Prosthesis Implantation mortality, Hospital Mortality, Humans, Male, Middle Aged, Prosthesis Design, Reoperation, Retrospective Studies, Risk Factors, Time Factors, Treatment Outcome, Young Adult, Aorta surgery, Aortic Valve surgery, Aortic Valve Insufficiency surgery, Bioprosthesis, Blood Vessel Prosthesis, Blood Vessel Prosthesis Implantation instrumentation, Heart Valve Prosthesis, Heart Valve Prosthesis Implantation instrumentation
- Abstract
Background: Autograft valve preservation at reoperation may conserve some of the advantages of the Ross procedure. However, results of long-term follow-up are lacking. In this retrospective multicenter study, we present our experience with valve-sparing reoperations after the Ross procedure, with a focus on long-term outcome., Methods: A total of 86 patients from 6 European centers, who underwent valve-sparing reoperation after the Ross procedure between 1997 and 2013, were included in the study., Results: Reoperation was performed a median of 9.1 years after the Ross procedure in patients with a median age of 38.4 years (interquartile range: 27.1-51.6 years). Preoperative severe autograft regurgitation (grade ≥3) was present in 46% of patients. In-hospital mortality was 1%. During a median follow-up of 4.3 years, 3 more patients died of noncardiac causes, resulting in a cumulative survival at 8 years of 89% (95% confidence interval: 65%-97%). Fifteen patients required a reintervention after valve-sparing reoperation, mostly owing to prolapse or retraction of autograft cusps. Freedom from reintervention was 76% (95% confidence interval: 57%-87%) at 8 years. The reintervention hazard was increased in patients who had isolated and/or severe aortic regurgitation at valve-sparing reoperation. In patients without reintervention after valve-sparing autograft reoperation (n = 63), severe aortic regurgitation was present in 3% at last follow-up., Conclusions: Valve-sparing autograft reoperations after the Ross procedure carry a low operative risk, with acceptable reintervention rates in the first postoperative decade. Patients with isolated and/or severe autograft regurgitation have an increased hazard of reintervention after valve-sparing reoperation; for these patients, careful preoperative weighing of surgical options is required., (Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.)
- Published
- 2015
- Full Text
- View/download PDF
9. Under-use of the Ross operation--a lost opportunity.
- Author
-
Yacoub MH, El-Hamamsy I, Sievers HH, Carabello BA, Bonow RO, Stelzer P, da Costa FDA, Schäfers HJ, Skillington P, Charitos EI, Luciani GB, and Takkenberg JJM
- Subjects
- Heart Valve Diseases epidemiology, Humans, Quality of Life, Aortic Valve surgery, Heart Valve Diseases surgery, Heart Valve Prosthesis Implantation methods, Pulmonary Valve transplantation
- Published
- 2014
- Full Text
- View/download PDF
10. The fate of the bicuspid valve aortopathy after aortic valve replacement.
- Author
-
Charitos EI, Stierle U, Petersen M, Mohamed SA, Hanke T, Schmidtke C, Klotz S, and Sievers HH
- Subjects
- Adult, Aortic Valve surgery, Bicuspid Aortic Valve Disease, Female, Hemodynamics physiology, Humans, Male, Middle Aged, Retrospective Studies, Sinus of Valsalva pathology, Treatment Outcome, Aorta pathology, Aortic Valve abnormalities, Heart Valve Diseases epidemiology, Heart Valve Diseases surgery, Heart Valve Prosthesis Implantation adverse effects, Heart Valve Prosthesis Implantation methods
- Abstract
Objectives: The fate of the aortic dimensions in patients with a bicuspid aortic valve (BAV) after aortic valve replacement (AVR) is unclear. We investigated the evolution of aortic root and ascending aorta dimensions in patients with a BAV after AVR. To neutralize the effect of pathological transvalvular haemodynamics on aortic dimensions, we evaluated our hypotheses in patients with normal transvalvular haemodynamics after a subcoronary autograft procedure, which preserves intact the native aortic wall., Methods: We excluded patients operated on for endocarditis; who developed autograft insufficiency > trivial and who required autograft reoperation during the follow-up. We included 448 patients (361 with BAV; 340 males; 44.6 ± 11.4 years; mean follow-up: 7.5 ± 3.9 years). Valve phenotype was determined during surgery. Annual echocardiographic examinations (n = 3336) were performed (follow-up completeness: 98%). To allow for somatometric, gender and age influences, z-values of measurements were calculated from the general population (GP) and analysed using longitudinal methods., Results: The increase in ascending aorta did not differ from that expected in the GP (0.04 z-values/year; P = 0.06). No difference could be observed in diameter increase rates between BAV and tricuspid aortic valve patients (TAV) (0.04 vs 0.06 z-values/year; P = 0.3), as well as between BAV phenotypes. The sinus increase did not differ from that expected in the GP (0.03 z-values/year; P = 0.1), and no significant differences could be observed between BAV phenotypes. In patients undergoing aortoplasty (n = 70), no significant difference in the rates of ascending aorta and sinus increase could be observed, compared with the GP., Conclusion: For the time period of this study and in patients with normal aortic root haemodynamics after AVR, ascending aorta dimensions over time are similar to that of the matched GP. Patients with a BAV did not exhibit higher rates of ascending aorta dilatation after AVR than patients with TAV. At least for the first postoperative decade, transvalvular haemodynamics appear to exhibit a greater influence than the genetic component of BAV on the development of the BAV aortopathy.
- Published
- 2014
- Full Text
- View/download PDF
11. Reoperations on the pulmonary autograft and pulmonary homograft after the Ross procedure: An update on the German Dutch Ross Registry.
- Author
-
Charitos EI, Takkenberg JJ, Hanke T, Gorski A, Botha C, Franke U, Dodge-Khatami A, Hoerer J, Lange R, Moritz A, Ferrari-Kuehne K, Hetzer R, Huebler M, Bogers AJ, Stierle U, Sievers HH, and Hemmer W
- Subjects
- Adolescent, Adult, Aged, Aortic Valve physiopathology, Blood Vessel Prosthesis Implantation adverse effects, Blood Vessel Prosthesis Implantation mortality, Child, Child, Preschool, Female, Germany, Heart Valve Diseases mortality, Heart Valve Diseases physiopathology, Heart Valve Prosthesis Implantation adverse effects, Heart Valve Prosthesis Implantation mortality, Hemodynamics, Humans, Infant, Infant, Newborn, Male, Middle Aged, Multivariate Analysis, Netherlands, Postoperative Complications etiology, Postoperative Complications mortality, Postoperative Complications physiopathology, Proportional Hazards Models, Registries, Reoperation, Retrospective Studies, Risk Assessment, Risk Factors, Survival Analysis, Transplantation, Autologous, Transplantation, Homologous, Treatment Outcome, Young Adult, Aortic Valve surgery, Bioprosthesis, Blood Vessel Prosthesis, Blood Vessel Prosthesis Implantation instrumentation, Heart Valve Diseases surgery, Heart Valve Prosthesis, Heart Valve Prosthesis Implantation instrumentation, Postoperative Complications surgery, Pulmonary Artery transplantation, Pulmonary Valve transplantation
- Abstract
Objectives: Reinterventions after the Ross procedure are a concern for patients and treating physicians. The scope of the present report was to provide an update on the reinterventions observed in the large patient population of the German-Dutch Ross Registry., Patients and Methods: From 1988 to 2011, 2023 patients (age, 39.05 ± 16.5 years; male patients, 1502; adults, 1642) underwent a Ross procedure in 13 centers. The mean follow-up was 7.1 ± 4.6 years (range, 0-22 years; 13,168 patient-years)., Results: In the adult population, 120 autograft reinterventions in 113 patients (1.03%/patient-year) and 76 homograft reinterventions in 67 patients (0.65%/patient-year) and, in the pediatric population, 14 autograft reinterventions in 13 patients (0.91%/patient-year) and 42 homograft reinterventions in 31 patients (2.72%/patient-year) were observed. Of the autograft and homograft reinterventions, 17.9% and 21.2% were performed because of endocarditis, respectively. The subcoronary technique in the adult population resulted in significantly superior autograft durability (freedom from autograft reintervention: 97% at 10 years and 91% at 12 years; P < .001). The root replacement technique without root reinforcement (hazard ratio, 2.4; 95% confidence interval, 1.4-4.1) and the presence of pure aortic insufficiency preoperatively (hazard ratio, 2.3; 95% confidence interval, 1.5-3.5) were statistically significant predictors for a shorter time to reoperation. The center volume had a significant influence on the long-term results. The freedom from homograft reoperation for the adults and pediatric population was 97% and 87% at 5 years and 93% and 79% at 12 years, respectively (P < .001), with younger recipient and donor age being significant predictors of a shorter time to homograft reoperation., Conclusions: The autograft principle remains a valid option for young patients requiring aortic valve replacement. The risk of reoperation depends largely on the surgical technique used and the preoperative hemodynamics. Center experience and expertise also influence the long-term results. Adequate endocarditis prophylaxis might further reduce the need for reoperation., (Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.)
- Published
- 2012
- Full Text
- View/download PDF
12. Letter by Charitos et al regarding article, "Reoperation of left heart valve bioprostheses according to age at implantation".
- Author
-
Charitos EI, Stierle U, and Sievers HH
- Subjects
- Humans, Aortic Valve surgery, Bioprosthesis, Heart Valve Diseases surgery, Heart Valve Prosthesis, Heart Valve Prosthesis Implantation statistics & numerical data, Mitral Valve surgery
- Published
- 2012
- Full Text
- View/download PDF
13. Survival comparison of the Ross procedure and mechanical valve replacement with optimal self-management anticoagulation therapy: propensity-matched cohort study.
- Author
-
Mokhles MM, Körtke H, Stierle U, Wagner O, Charitos EI, Bogers AJ, Gummert J, Sievers HH, and Takkenberg JJ
- Subjects
- Adolescent, Adult, Aortic Diseases drug therapy, Aortic Diseases surgery, Cardiac Surgical Procedures standards, Cohort Studies, Female, Follow-Up Studies, Humans, Male, Middle Aged, Prospective Studies, Registries, Treatment Outcome, Young Adult, Anticoagulants therapeutic use, Heart Valve Diseases drug therapy, Heart Valve Diseases surgery, Heart Valve Prosthesis Implantation standards, Propensity Score, Self Care standards
- Abstract
Background: It is suggested that in young adults the Ross procedure results in better late patient survival compared with mechanical prosthesis implantation. We performed a propensity score-matched study that assessed late survival in young adult patients after a Ross procedure versus that after mechanical aortic valve replacement with optimal self-management anticoagulation therapy., Methods and Results: We selected 918 Ross patients and 406 mechanical valve patients 18 to 60 years of age without dissection, aneurysm, or mitral valve replacement who survived an elective procedure (1994 to 2008). With the use of propensity score matching, late survival was compared between the 2 groups. Two hundred fifty-three patients with a mechanical valve (mean follow-up, 6.3 years) could be propensity matched to a Ross patient (mean follow-up, 5.1 years). Mean age of the matched cohort was 47.3 years in the Ross procedure group and 48.0 years in the mechanical valve group (P=0.17); the ratio of male to female patients was 3.2 in the Ross procedure group and 2.7 in the mechanical valve group (P=0.46). Linearized all-cause mortality rate was 0.53% per patient-year in the Ross procedure group compared with 0.30% per patient-year in the mechanical valve group (matched hazard ratio, 1.86; 95% confidence interval, 0.58 to 5.91; P=0.32). Late survival was comparable to that of the general German population., Conclusions: In comparable patients, there is no late survival difference in the first postoperative decade between the Ross procedure and mechanical aortic valve implantation with optimal anticoagulation self-management. Survival in these selected young adult patients closely resembles that of the general population, possibly as a result of highly specialized anticoagulation self-management, better timing of surgery, and improved patient selection in recent years.
- Published
- 2011
- Full Text
- View/download PDF
14. Fourteen years' experience with 501 subcoronary Ross procedures: surgical details and results.
- Author
-
Sievers HH, Stierle U, Charitos EI, Hanke T, Gorski A, Misfeld M, and Bechtel M
- Subjects
- Adult, Aortic Valve physiopathology, Databases as Topic, Disease-Free Survival, Female, Germany, Heart Valve Diseases mortality, Heart Valve Diseases physiopathology, Hemodynamics, Humans, Kaplan-Meier Estimate, Life Expectancy, Male, Middle Aged, Reoperation, Risk Assessment, Risk Factors, Time Factors, Transplantation, Autologous, Treatment Outcome, Young Adult, Aortic Valve surgery, Heart Valve Diseases surgery, Heart Valve Prosthesis Implantation adverse effects, Heart Valve Prosthesis Implantation mortality
- Abstract
Objective: During the past decade the Ross procedure using the full root has become the predominant surgical technique. However, progressive autograft dilatation and eventual failure remain a concern. Here we report on the surgical techniques and results of the subcoronary technique over a 14-year period., Methods: A total of 501 patients (mean age, 44.9 ± 12.9 years; 117 female; 384 male) were operated on from June 1994 to December 2007. The follow-up database, with a completeness of 98.2%, was closed on December 2008, comprising of 2931 patient-years with a mean follow-up of 5.9 ± 3.6 years (range, 0.1-14.1 years)., Results: Surgical details are presented. Early and late mortality were 0.4% (n = 2) and 4% (n = 20), respectively, valve-related mortality was 1.2% (n = 6), whereas the overall survival did not differ from that of the normal population. Neurologic events occurred in 22 patients, major bleeding in 9, autograft endocarditis in 8, and homograft endocarditis in 10. Freedom from autograft and homograft reoperation was 91.9% at 10 years. For the majority of patients, hemodynamics was excellent and no root dilatation was observed., Conclusions: Midterm results after the original subcoronary Ross procedure are excellent, including normal survival and low risk of valve-related morbidity. Longer-term results are necessary for continuous judgment of the subcoronary technique., (Copyright © 2010 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.)
- Published
- 2010
- Full Text
- View/download PDF
15. The Ross operation - a feasible and safe option in the setting of a bicuspid aortic valve?
- Author
-
Hanke T, Charitos EI, Stierle U, Robinson DR, Hemmer W, Moritz A, Lange R, and Sievers HH
- Subjects
- Adolescent, Adult, Aorta surgery, Aortic Valve pathology, Aortic Valve surgery, Aortic Valve Insufficiency etiology, Blood Vessel Prosthesis Implantation methods, Epidemiologic Methods, Female, Heart Valve Prosthesis Implantation adverse effects, Humans, Male, Middle Aged, Reoperation methods, Sinus of Valsalva pathology, Treatment Outcome, Young Adult, Aortic Valve abnormalities, Heart Valve Diseases surgery, Heart Valve Prosthesis Implantation methods, Pulmonary Valve transplantation
- Abstract
Objectives: The Ross operation in the setting of a bicuspid aortic valve (BAV) remains controversial. Using data from the German Ross Registry, we sought to investigate the effect of the presence of a BAV on autograft function and diameters over time after the Ross operation compared with the presence of a tricuspid aortic valve (TAV)., Methods: A total of 1277 patients (mean age 42.2 + or - 15.3 years) with intra-operatively documented aortic valve morphology during the Ross operation were analysed in the present study (sub-coronary technique, n=648, root replacement technique, n=629 patients). A BAV was present in 70.9% of patients. Clinical and echocardiographic follow-up was performed preoperatively and at pre-specified intervals (mean follow-up 5.7 + or - 3.8 years, 6806 patient-years). Hierarchical multilevel modelling techniques were used for the statistical analysis of serial measurements and comparisons among groups., Results: Initial neo-aortic regurgitation was lower in the BAV group (0.52 vs 0.62 aortic insufficiency (AI) grades, p=0.008), whereas the annual increase of it did not differ among groups. In both surgical techniques, no significant development of neo-aortic regurgitation (<0.02 AI grades per year) could be detected. Initial aortic annulus and sinus dimensions did not differ in the presence of a BAV. However, BAV patients developed a higher degree of annulus and sinus dilatation over time (0.20mm per year vs 0.06 mm per year, p=0.003; 0.24 vs 0.11 mm per year, p=0.013). This effect persisted when allowing for the two different surgical techniques. Baseline sinotubular junction (STJ) diameters did not differ among groups and annual increase thereof was similar (29.15 mm vs 28.9 mm, p=0.69; 0.44 mm vs 0.35 mm, p=0.15)., Conclusions: For the observed time period, postoperative neo-aortic regurgitation after the Ross procedure did not differ between patients with a BAV or a TAV. Root dimensions, although clinically not relevant, increased in both valve entities supporting surgical reinforcement strategies. We cannot consider a BAV as a contraindication for the Ross operation., (Copyright 2010. Published by Elsevier B.V.)
- Published
- 2010
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.