1. Accuracy of FDG-PET-CT in the diagnostic work-up of vascular prosthetic graft infection.
- Author
-
Bruggink JL, Glaudemans AW, Saleem BR, Meerwaldt R, Alkefaji H, Prins TR, Slart RH, and Zeebregts CJ
- Subjects
- Aged, Blood Vessel Prosthesis Implantation instrumentation, Female, Humans, Male, Middle Aged, Observer Variation, Predictive Value of Tests, Prosthesis-Related Infections diagnostic imaging, Prosthesis-Related Infections microbiology, Reproducibility of Results, Retrospective Studies, Sensitivity and Specificity, Blood Vessel Prosthesis adverse effects, Blood Vessel Prosthesis Implantation adverse effects, Fluorodeoxyglucose F18, Positron-Emission Tomography, Prosthesis-Related Infections diagnosis, Prosthesis-Related Infections etiology, Radiopharmaceuticals, Tomography, X-Ray Computed
- Abstract
Objectives: To investigate the diagnostic accuracy of fluoro-2-deoxy-d-glucose positron emission tomography (FDG-PET) compared with computed tomography (CT) scanning and added value of fused FDG-PET-CT in diagnosing vascular prosthetic graft infection., Design: Prospective cohort study with retrospective analysis., Materials: Twenty five patients with clinically suspected vascular prosthetic infection underwent CT and FDG-PET scanning., Methods: Two nuclear medicine physicians assessed the FDG-PET scans; all CT scans were assessed by two radiologists. Fused FDG-PET/CT were judged by the radiologist and the nuclear medicine physician. The concordance between CT and FDG-PET and the inter-observer agreement between the different readers were investigated., Results: Fifteen patients had a proven infection by culture. Single FDG-PET had the best results (sensitivity 93%, specificity 70%, positive predictive value 82% and negative predictive value 88%). For CT, these values were 56%, 57%, 60% and 58%, respectively. Fused CT and FDG-PET imaging also showed high sensitivity and specificity rates and high positive and negative values. Inter-observer agreement for FDG-PET analysis was excellent (kappa = 1.00) and moderate for CT and fused FDG-PET-CT analysis (0.63 and 0.66, respectively)., Conclusion: FDG-PET scanning showed a better diagnostic accuracy than CT for the detection of vascular prosthetic infection. This study suggests that FDG-PET provides a useful tool in the work-up for diagnosis of vascular prosthetic graft infection., (Copyright 2010 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.)
- Published
- 2010
- Full Text
- View/download PDF