1. Conduction disorders following transcatheter aortic valve replacement using acurate Neo2 transcatheter heart valve: A propensity matched analysis.
- Author
-
Loewenstein I, Finkelstein A, Banai S, Halkin A, Konigstein M, Ben-Shoshan J, Arbel Y, Barbash I, Segev A, David P, Elbaz-Greener G, Assa-Vaknin H, Kornowski R, Dvir D, Asher E, and Steinvil A
- Subjects
- Humans, Male, Female, Retrospective Studies, Treatment Outcome, Aged, 80 and over, Aged, Israel, Risk Factors, Time Factors, Risk Assessment, Atrioventricular Block diagnosis, Atrioventricular Block etiology, Atrioventricular Block physiopathology, Atrioventricular Block therapy, Bundle-Branch Block physiopathology, Bundle-Branch Block diagnosis, Bundle-Branch Block etiology, Bundle-Branch Block therapy, Arrhythmias, Cardiac diagnosis, Arrhythmias, Cardiac physiopathology, Arrhythmias, Cardiac therapy, Arrhythmias, Cardiac etiology, Heart Rate, Propensity Score, Transcatheter Aortic Valve Replacement adverse effects, Transcatheter Aortic Valve Replacement instrumentation, Prosthesis Design, Heart Valve Prosthesis, Aortic Valve surgery, Aortic Valve physiopathology, Aortic Valve diagnostic imaging, Registries, Aortic Valve Stenosis surgery, Aortic Valve Stenosis physiopathology, Aortic Valve Stenosis diagnostic imaging, Cardiac Pacing, Artificial
- Abstract
Background: The ACURATE neo2 transcatheter aortic valve was developed to improve paravalvular leak (PVL) rates while maintaining low rates of conduction disturbances and permanent pacemaker implantation (PPMI) seen with its predecessor. We aimed to compare conduction disturbances rates of transcatheter aortic valve replacement (TAVR) using ACURATE Neo2 with other commonly used valves., Methods: A retrospective analysis of the Israeli TAVR registry between the years 2014-2023 was performed to compare conduction disturbances and PVL rates, and procedural outcomes, among patients treated with ACURATE neo2, Edwards Sapien 3 (S3), and Evolut PRO valves. Propensity score matching was performed to compare groups with similar characteristics., Results: Following exclusion of patients with non-femoral access, unknown valve type, older-generation valves, and less commonly used valves or (n = 4387), our analysis included 3208 patients undergoing TAVR using ACURATE neo2, Edwards S3, and Evolut PRO valves. Propensity matched groups comprised 169 patients each. Rates of any conduction disturbances [left bundle branch block (LBBB), atrioventricular block, or PPMI] were lower in the ACURATE neo2 group compared to both other valves [15.8 %, S3-37.5 % (p < 0.001), Evolut PRO-27.5 % (p = 0.02)] as were LBBB rates [9.0 %, S3-31.3 % (p < 0.001); Evolut PRO-20.1 % (p = 0.01). Atrioventricular block and PPMI rates were lower without statistical significance, as were rates of above-moderate PVL., Conclusions: In this analysis, TAVR using ACURATE neo2 was associated with a lower composite rate of conduction disturbances in comparison to the Evolut PRO and Edwards S3 valves, mainly due to lower left bundle branch block rates, with non-significantly lower rates of PPMI and PVL., Competing Interests: Declaration of competing interest Prof. Ariel Finkelstein reports a relationship with Medtronic Inc. that includes: consulting or advisory. Prof. Ariel Finkelstein reports a relationship with Edwards Lifesciences Corporation that includes: consulting or advisory. Prof. Amir Halkin reports a relationship with Abbott Laboratories that includes: consulting or advisory. Prof. Amir Halkin reports a relationship with Boston Scientific Corp that includes: consulting or advisory. Other authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper., (Copyright © 2024 Elsevier Inc. All rights reserved.)
- Published
- 2024
- Full Text
- View/download PDF