1. Automated IR determination of petroleum products in water based on sequential injection analysis
- Author
-
Andrey Shishov, Christina Vakh, Ekaterina A. Zubakina, Aleksey L. Moskvin, Marina T. Falkova, Andrey Bulatov, and Leonid Moskvin
- Subjects
Detection limit ,Sequential injection analysis ,business.industry ,Chemistry ,Calibration curve ,010401 analytical chemistry ,Extraction (chemistry) ,Analytical chemistry ,Sampling (statistics) ,010501 environmental sciences ,01 natural sciences ,Water based ,0104 chemical sciences ,Analytical Chemistry ,Cartridge ,Petroleum product ,business ,0105 earth and related environmental sciences - Abstract
The simple and easy performed automated method for the IR determination of petroleum products (PP) in water using extraction-chromatographic cartridges has been developed. The method assumes two stages: on-site extraction of PP during a sampling by using extraction-chromatographic cartridges and subsequent determination of the extracted PP using sequential injection analysis (SIA) with IR detection. The appropriate experimental conditions for extraction of the dissolved in water PP and for automated SIA procedure were investigated. The calibration plot constructed using the developed procedure was linear in the range of 3–200 μg L −1 . The limit of detection (LOD), calculated from a blank test based on 3σ was 1 µg L −1 . The sample volume was 1 L. The system throughput was found to be 12 h −1 .
- Published
- 2015