1. Valve performance classification in 630 subcoronary Ross patients over 22 years.
- Author
-
Sievers HH, Stierle U, Petersen M, Klotz S, Richardt D, Diwoky M, and Charitos EI
- Subjects
- Adult, Aortic Valve diagnostic imaging, Aortic Valve physiopathology, Blood Vessel Prosthesis Implantation adverse effects, Blood Vessel Prosthesis Implantation mortality, Female, Hemodynamics, Hospital Mortality, Humans, Male, Middle Aged, Postoperative Complications mortality, Postoperative Complications surgery, Progression-Free Survival, Prospective Studies, Prosthesis Design, Recovery of Function, Reoperation, Risk Factors, Time Factors, Young Adult, Aortic Valve surgery, Bioprosthesis, Blood Vessel Prosthesis, Blood Vessel Prosthesis Implantation instrumentation
- Abstract
Objective: To define the function of the "Ross valves" and its clinical meaning in a practical valve performance classification as part of the outcome analysis., Methods: From 1994 to 2017, 630 consecutive patients underwent the subcoronary Ross procedure at our institution. The valve performance classification combines hemodynamics, symptoms, and management criteria. Median follow-up was 12.5 years (maximum 22.3 years, 7404 patient-years, 99.4% completeness)., Results: The mean age of the patients was 44.7 ± 11.9 years. Hospital deaths was 0.3% (n = 2). Twenty years after the operation survival was 73.1% (95% confidence interval [CI], 65.4%-81.6%) and statistically not different from the age- and gender-matched general population; freedom from reoperation was 85.9% (95% CI, 80.2%-92.0%; 0.6% per patient-year), 89.8% (95% CI, 84.3%-95.7%) for autograft, and 91.0% (95% CI, 86.3%-96.0%) for homograft. Preoperative annulus diameter, aortic regurgitation, annulus reinforcement, sinotubular junction reinforcement, and bicuspid aortic valve type were no significant risk factors for reoperation. At 20 years the probability of a patient being in valve performance class I to IV was 5%, 74%, 19%, and 1%, respectively. Time to reoperation was not different in bicuspid and tricuspid aortic valves; preoperative aortic stenosis tended to have better outcome of autograft function., Conclusions: These up to 22 years data show that the subcoronary Ross procedure continues to provide an excellent tissue aortic valve replacement. The suggested valve performance classification emerged as a practical concept for outcome analysis with the probability of 79% being in the favorable class I or II at 20 years., (Copyright © 2018 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.)
- Published
- 2018
- Full Text
- View/download PDF