1. Variation in Attenuation in L1 Trabecular Bone at Different Tube Voltages: Caution Is Warranted When Screening for Osteoporosis With the Use of Opportunistic CT
- Author
-
Daniel E. Wessell, Perry J. Pickhardt, Hillary W. Garner, Michelle M Paturzo, and Gabriela Gaudier
- Subjects
Male ,medicine.medical_specialty ,Osteoporosis ,Radiation Dosage ,Sensitivity and Specificity ,Bone and Bones ,030218 nuclear medicine & medical imaging ,Radiography, Dual-Energy Scanned Projection ,03 medical and health sciences ,0302 clinical medicine ,Hounsfield scale ,medicine ,Humans ,Mass Screening ,Radiology, Nuclear Medicine and imaging ,Tube (fluid conveyance) ,Diagnostic Errors ,Opportunistic screening ,Pelvis ,Aged ,Aged, 80 and over ,business.industry ,Attenuation ,Reproducibility of Results ,General Medicine ,Middle Aged ,medicine.disease ,Radiographic Image Enhancement ,Trabecular bone ,medicine.anatomical_structure ,Radiographic Image Interpretation, Computer-Assisted ,Abdomen ,Female ,Radiology ,Artifacts ,Tomography, X-Ray Computed ,Nuclear medicine ,business ,030217 neurology & neurosurgery - Abstract
The purpose of this study is to investigate the variation in attenuation values (expressed as Hounsfield units) for L1 vertebral body trabecular bone at different tube voltages used in dual-energy CT (DECT) and to remind physicians to consider changes in attenuation values when they approach opportunistic screening for osteoporosis.Consecutive patients who underwent DECT examination of the abdomen and pelvis for suspected urolithiasis were included in the study. Attenuation noted on CT of the L1 trabecular bone performed with the use of tube voltages of 80, 100, and 140 kV was recorded. The correlation between the attenuation noted when the tube voltage was 140 kV and the attenuation noted when the tube voltage was either 80 or 100 kV was calculated, and differences in the mean CT attenuation values were compared.The mean attenuation values from L1 trabecular bone measurement performed for 191 patients were analyzed. As expected, the mean attenuation values decreased as the tube voltage increased. There was a strong correlation between the attenuation values noted when tube voltages of 80 and 140 kV were used (rWe confirmed that attenuation values of L1 trabecular bone, unlike attenuation values of fat, fluid, or soft tissue, vary at different CT x-ray tube voltages. Therefore, standard reference attenuation values for trabecular bone seen at 120 kV cannot be applied to other single-energy settings, DECT, or CT examinations where dose modulation software automatically raises or lowers the tube voltage from 120 kV. Knowledge of the specific energy spectra used is essential before performing opportunistic CT evaluation for osteoporosis.
- Published
- 2017
- Full Text
- View/download PDF