Back to Search
Start Over
Variation in Attenuation in L1 Trabecular Bone at Different Tube Voltages: Caution Is Warranted When Screening for Osteoporosis With the Use of Opportunistic CT
- Source :
- American Journal of Roentgenology. 208:165-170
- Publication Year :
- 2017
- Publisher :
- American Roentgen Ray Society, 2017.
-
Abstract
- The purpose of this study is to investigate the variation in attenuation values (expressed as Hounsfield units) for L1 vertebral body trabecular bone at different tube voltages used in dual-energy CT (DECT) and to remind physicians to consider changes in attenuation values when they approach opportunistic screening for osteoporosis.Consecutive patients who underwent DECT examination of the abdomen and pelvis for suspected urolithiasis were included in the study. Attenuation noted on CT of the L1 trabecular bone performed with the use of tube voltages of 80, 100, and 140 kV was recorded. The correlation between the attenuation noted when the tube voltage was 140 kV and the attenuation noted when the tube voltage was either 80 or 100 kV was calculated, and differences in the mean CT attenuation values were compared.The mean attenuation values from L1 trabecular bone measurement performed for 191 patients were analyzed. As expected, the mean attenuation values decreased as the tube voltage increased. There was a strong correlation between the attenuation values noted when tube voltages of 80 and 140 kV were used (rWe confirmed that attenuation values of L1 trabecular bone, unlike attenuation values of fat, fluid, or soft tissue, vary at different CT x-ray tube voltages. Therefore, standard reference attenuation values for trabecular bone seen at 120 kV cannot be applied to other single-energy settings, DECT, or CT examinations where dose modulation software automatically raises or lowers the tube voltage from 120 kV. Knowledge of the specific energy spectra used is essential before performing opportunistic CT evaluation for osteoporosis.
- Subjects :
- Male
medicine.medical_specialty
Osteoporosis
Radiation Dosage
Sensitivity and Specificity
Bone and Bones
030218 nuclear medicine & medical imaging
Radiography, Dual-Energy Scanned Projection
03 medical and health sciences
0302 clinical medicine
Hounsfield scale
medicine
Humans
Mass Screening
Radiology, Nuclear Medicine and imaging
Tube (fluid conveyance)
Diagnostic Errors
Opportunistic screening
Pelvis
Aged
Aged, 80 and over
business.industry
Attenuation
Reproducibility of Results
General Medicine
Middle Aged
medicine.disease
Radiographic Image Enhancement
Trabecular bone
medicine.anatomical_structure
Radiographic Image Interpretation, Computer-Assisted
Abdomen
Female
Radiology
Artifacts
Tomography, X-Ray Computed
Nuclear medicine
business
030217 neurology & neurosurgery
Subjects
Details
- ISSN :
- 15463141 and 0361803X
- Volume :
- 208
- Database :
- OpenAIRE
- Journal :
- American Journal of Roentgenology
- Accession number :
- edsair.doi.dedup.....b36290877a54ac4c3db6afc3a363d646
- Full Text :
- https://doi.org/10.2214/ajr.16.16744