150 results on '"Luetkens JA"'
Search Results
2. Acute complications of giant coronary aneurysms in Kawasaki disease.
- Author
-
Beissel LD, Hart C, and Luetkens JA
- Abstract
Competing Interests: Conflict of interest: J.A.L.: scientific advisory board of Bayer Healthcare; payments for lectures from Bayer Healthcare, GE HealthCare, Novartis, Philips Healthcare, and Siemens Healthcare. C.H. and L.D.B.: nothing to declare.
- Published
- 2024
- Full Text
- View/download PDF
3. Deep learning super-resolution reconstruction for fast and high-quality cine cardiovascular magnetic resonance.
- Author
-
Kravchenko D, Isaak A, Mesropyan N, Peeters JM, Kuetting D, Pieper CC, Katemann C, Attenberger U, Emrich T, Varga-Szemes A, and Luetkens JA
- Abstract
Objectives: To compare standard-resolution balanced steady-state free precession (bSSFP) cine images with cine images acquired at low resolution but reconstructed with a deep learning (DL) super-resolution algorithm., Materials and Methods: Cine cardiovascular magnetic resonance (CMR) datasets (short-axis and 4-chamber views) were prospectively acquired in healthy volunteers and patients at normal (cine
NR : 1.89 × 1.96 mm2 , reconstructed at 1.04 × 1.04 mm2 ) and at a low-resolution (2.98 × 3.00 mm2 , reconstructed at 1.04 × 1.04 mm2 ). Low-resolution images were reconstructed using compressed sensing DL denoising and resolution upscaling (cineDL ). Left ventricular ejection fraction (LVEF), end-diastolic volume index (LVEDVi), and strain were assessed. Apparent signal-to-noise (aSNR) and contrast-to-noise ratios (aCNR) were calculated. Subjective image quality was assessed on a 5-point Likert scale. Student's paired t-test, Wilcoxon matched-pairs signed-rank-test, and intraclass correlation coefficient (ICC) were used for statistical analysis., Results: Thirty participants were analyzed (37 ± 16 years; 20 healthy volunteers and 10 patients). Short-axis views whole-stack acquisition duration of cineDL was shorter than cineNR (57.5 ± 8.7 vs 98.7 ± 12.4 s; p < 0.0001). No differences were noted for: LVEF (59 ± 7 vs 59 ± 7%; ICC: 0.95 [95% confidence interval: 0.94, 0.99]; p = 0.17), LVEDVi (85.0 ± 13.5 vs 84.4 ± 13.7 mL/m2 ; ICC: 0.99 [0.98, 0.99]; p = 0.12), longitudinal strain (-19.5 ± 4.3 vs -19.8 ± 3.9%; ICC: 0.94 [0.88, 0.97]; p = 0.52), short-axis aSNR (81 ± 49 vs 69 ± 38; p = 0.32), aCNR (53 ± 31 vs 45 ± 27; p = 0.33), or subjective image quality (5.0 [IQR 4.9, 5.0] vs 5.0 [IQR 4.7, 5.0]; p = 0.99)., Conclusion: Deep-learning reconstruction of cine images acquired at a lower spatial resolution led to a decrease in acquisition times of 42% with shorter breath-holds without affecting volumetric results or image quality., Key Points: Question Cine CMR acquisitions are time-intensive and vulnerable to artifacts. Findings Low-resolution upscaled reconstructions using DL super-resolution decreased acquisition times by 35-42% without a significant difference in volumetric results or subjective image quality. Clinical relevance DL super-resolution reconstructions of bSSFP cine images acquired at a lower spatial resolution reduce acquisition times while preserving diagnostic accuracy, improving the clinical feasibility of cine imaging by decreasing breath hold duration., (© 2024. The Author(s).)- Published
- 2024
- Full Text
- View/download PDF
4. Gadolinium-based coronary CT angiography on a clinical photon-counting-detector system: a dynamic circulating phantom study.
- Author
-
Kravchenko D, Gnasso C, Schoepf UJ, Vecsey-Nagy M, Tremamunno G, O'Doherty J, Zhang A, Luetkens JA, Kuetting D, Attenberger U, Schmidt B, Varga-Szemes A, and Emrich T
- Subjects
- Humans, Photons, Gadolinium DTPA administration & dosage, Phantoms, Imaging, Computed Tomography Angiography methods, Contrast Media administration & dosage, Coronary Angiography methods
- Abstract
Background: Coronary computed tomography angiography (CCTA) offers non-invasive diagnostics of the coronary arteries. Vessel evaluation requires the administration of intravenous contrast. The purpose of this study was to evaluate the utility of gadolinium-based contrast agent (GBCA) as an alternative to iodinated contrast for CCTA on a first-generation clinical dual-source photon-counting-detector (PCD)-CT system., Methods: A dynamic circulating phantom containing a three-dimensional-printed model of the thoracic aorta and the coronary arteries were used to evaluate injection protocols using gadopentetate dimeglumine at 50%, 100%, 150%, and 200% of the maximum approved clinical dose (0.3 mmol/kg). Virtual monoenergetic image (VMI) reconstructions ranging from 40 keV to 100 keV with 5 keV increments were generated on a PCD-CT. Contrast-to-noise ratio (CNR) was calculated from attenuations measured in the aorta and coronary arteries and noise measured in the background tissue. Attenuation of at least 350 HU was deemed as diagnostic., Results: The highest coronary attenuation (441 ± 23 HU, mean ± standard deviation) and CNR (29.5 ± 1.5) was achieved at 40 keV and at the highest GBCA dose (200%). There was a systematic decline of attenuation and CNR with higher keV reconstructions and lower GBCA doses. Only reconstructions at 40 and 45 keV at 200% and 40 keV at 150% GBCA dose demonstrated sufficient attenuation above 350 HU., Conclusion: Current PCD-CT protocols and settings are unsuitable for the use of GBCA for CCTA at clinically approved doses. Future advances to the PCD-CT system including a 4-threshold mode, as well as multi-material decomposition may add new opportunities for k-edge imaging of GBCA., Relevance Statement: Patients allergic to iodine-based contrast media and the future of multicontrast CT examinations would benefit greatly from alternative contrast media, but the utility of GBCA for coronary photon-counting-dector-CT angiography remains limited without further optimization of protocols and scanner settings., Key Points: GBCA-enhanced coronary PCD-CT angiography is not feasible at clinically approved doses. GBCAs have potential applications for the visualization of larger vessels, such as the aorta, on PCD-CT angiography. Higher GBCA doses and lower keV reconstructions achieved higher attenuation values and CNR., (© 2024. The Author(s).)
- Published
- 2024
- Full Text
- View/download PDF
5. Cardiac MRI in infarct-like myocarditis: transmural extension of late gadolinium enhancement is associated with worse outcomes.
- Author
-
Isaak A, Wirtz J, Kravchenko D, Mesropyan N, Bischoff LM, Bienert S, Weinhold L, Pieper CC, Attenberger U, Öztürk C, Zimmer S, Kuetting D, and Luetkens JA
- Abstract
Objectives: To assess the prognostic value of cardiac MRI (CMR) parameters for the occurrence of major adverse cardiac events (MACE) in patients with infarct-like myocarditis., Methods: In this retrospective single-center study, patients with CMR-confirmed acute myocarditis with infarct-like presentation were identified (2007-2020). Functional and structural parameters were analyzed including late gadolinium enhancement (LGE). The primary endpoint was the occurrence of MACE up to 5 years after discharge., Results: In total, 130 patients (mean age, 40 ± 19 years; 97 men, 75%) with infarct-like myocarditis were included. CMR was conducted a median of 3 days (interquartile range [IQR], 1-5) after symptom onset. MACE occurred in 18/130 patients (14%) during a median follow-up of 19.3 months (IQR, 4.5-53). The median extent of LGE was 7% (IQR, 4-10). LGE affected the subepicardium in 111/130 patients (85%), the midwall in 45/130 patients (35%), and both the subepicardium and midwall in 27/130 patients (21%). Transmural extension of non-ischemic LGE lesions was observed in 15/130 patients (12%) and septal LGE in 42/130 patients (32%). In univariable Cox regression analysis, a significant association was found between the occurrence of MACE and both, quantified LGE extent and transmural LGE pattern. In multivariable analysis, transmural extension of LGE was an independent predictor for MACE (hazard ratio, 6.34; 95% confidence interval: 2.29-17.49; p < 0.001). Patients with the transmural extension of LGE had a shorter event-free time on Kaplan-Meier analysis (log-rank p < 0.001)., Conclusions: MACE occurred in 14% of patients with infarct-like myocarditis during follow-up. A transmural extension of non-ischemic LGE was associated with a worse long-term prognosis., Critical Relevance Statement: CMR-based assessment of transmural extension of non-ischemic LGE holds the potential to serve as an easily assessable marker for risk stratification in patients with infarct-like myocarditis., Key Points: The prognostic value of CMR was studied in patients with infarct-like myocarditis. The extent of LGE and transmural extension were linked to adverse cardiac events. Transmural non-ischemic LGE can serve as an easily assessable prognostic marker., (© 2024. The Author(s).)
- Published
- 2024
- Full Text
- View/download PDF
6. Correction: Standards for conducting and reporting consensus and recommendation documents: European Society of Cardiovascular Radiology policy from the Guidelines Committee.
- Author
-
Lupi A, Suchá D, Cundari G, Fink N, Alkadhi H, Budde RPJ, Caobelli F, De Cecco CN, Galea N, Hrabak-Paar M, Loewe C, Luetkens JA, Muscogiuri G, Natale L, Nikolaou K, Pirnat M, Saba L, Salgado R, Williams MC, Wintersperger BJ, Vliegenthart R, Francone M, and Pepe A
- Published
- 2024
- Full Text
- View/download PDF
7. Deep Learning Virtual Contrast-Enhanced T1 Mapping for Contrast-Free Myocardial Extracellular Volume Assessment.
- Author
-
Nowak S, Bischoff LM, Pennig L, Kaya K, Isaak A, Theis M, Block W, Pieper CC, Kuetting D, Zimmer S, Nickenig G, Attenberger UI, Sprinkart AM, and Luetkens JA
- Subjects
- Humans, Retrospective Studies, Male, Female, Middle Aged, Adult, Amyloidosis diagnostic imaging, Amyloidosis pathology, Myocardium pathology, Magnetic Resonance Imaging, Cine methods, Image Interpretation, Computer-Assisted, Aged, Predictive Value of Tests, Deep Learning, Contrast Media, Myocarditis diagnostic imaging, Myocarditis pathology
- Abstract
Background: The acquisition of contrast-enhanced T1 maps to calculate extracellular volume (ECV) requires contrast agent administration and is time consuming. This study investigates generative adversarial networks for contrast-free, virtual extracellular volume (vECV) by generating virtual contrast-enhanced T1 maps., Methods and Results: This retrospective study includes 2518 registered native and contrast-enhanced T1 maps from 1000 patients who underwent cardiovascular magnetic resonance at 1.5 Tesla. Recent hematocrit values of 123 patients (hold-out test) and 96 patients from a different institution (external evaluation) allowed for calculation of conventional ECV. A generative adversarial network was trained to generate virtual contrast-enhanced T1 maps from native T1 maps for vECV creation. Mean and SD of the difference per patient (ΔECV) were calculated and compared by permutation of the 2-sided t test with 10 000 resamples. For ECV and vECV, differences in area under the receiver operating characteristic curve (AUC) for discriminating hold-out test patients with normal cardiovascular magnetic resonance versus myocarditis or amyloidosis were tested with Delong's test. ECV and vECV showed a high agreement in patients with myocarditis (ΔECV: hold-out test, 2.0%±1.5%; external evaluation, 1.9%±1.7%) and normal cardiovascular magnetic resonance (ΔECV: hold-out test, 1.9%±1.4%; external evaluation, 1.5%±1.2%), but variations in amyloidosis were higher (ΔECV: hold-out test, 6.2%±6.0%; external evaluation, 15.5%±6.4%). In the hold-out test, ECV and vECV had a comparable AUC for the diagnosis of myocarditis (ECV AUC, 0.77 versus vECV AUC, 0.76; P =0.76) and amyloidosis (ECV AUC, 0.99 versus vECV AUC, 0.96; P =0.52)., Conclusions: Generation of vECV on the basis of native T1 maps is feasible. Multicenter training data are required to further enhance generalizability of vECV in amyloidosis.
- Published
- 2024
- Full Text
- View/download PDF
8. Advancing MRI Technology with Deep Learning Super Resolution Reconstruction.
- Author
-
Luetkens JA and Kravchenko D
- Published
- 2024
- Full Text
- View/download PDF
9. Parametric mapping using cardiovascular magnetic resonance for the differentiation of light chain amyloidosis and transthyretin-related amyloidosis.
- Author
-
Kravchenko D, Isaak A, Zimmer S, Öztürk C, Mesropyan N, Bischoff LM, Voigt M, Ginzburg D, Attenberger U, Pieper CC, Kuetting D, and Luetkens JA
- Subjects
- Humans, Male, Female, Retrospective Studies, Aged, Diagnosis, Differential, Middle Aged, Cardiomyopathies diagnostic imaging, Amyloidosis diagnostic imaging, Case-Control Studies, Immunoglobulin Light-chain Amyloidosis diagnostic imaging, Immunoglobulin Light-chain Amyloidosis complications, Aged, 80 and over, ROC Curve, Analysis of Variance, Cohort Studies, Contrast Media, Amyloid Neuropathies, Familial diagnostic imaging, Amyloid Neuropathies, Familial complications, Magnetic Resonance Imaging, Cine methods
- Abstract
Aims: To evaluate different cardiovascular magnetic resonance (CMR) parameters for the differentiation of light chain amyloidosis (AL) and transthyretin-related amyloidosis (ATTR)., Methods and Results: In total, 75 patients, 53 with cardiac amyloidosis {20 patients with AL [66 ± 12 years, 14 males (70%)] and 33 patients with ATTR [78 ± 5 years, 28 males (88%)]} were retrospectively analysed regarding CMR parameters such as T1 and T2 mapping, extracellular volume (ECV), late gadolinium enhancement (LGE) distribution patterns, and myocardial strain, and compared to a control cohort with other causes of left ventricular hypertrophy {LVH; 22 patients [53 ± 16 years, 17 males (85%)]}. One-way ANOVA and receiver operating characteristic analysis were used for statistical analysis. ECV was the single best parameter to differentiate between cardiac amyloidosis and controls [area under the curve (AUC): 0.97, 95% confidence intervals (CI): 0.89-0.99, P < 0.0001, cut-off: >30%]. T2 mapping was the best single parameter to differentiate between AL and ATTR amyloidosis (AL: 63 ± 4 ms, ATTR: 58 ± 2 ms, P < 0.001, AUC: 0.86, 95% CI: 0.74-0.94, cut-off: >61 ms). Subendocardial LGE was predominantly observed in AL patients (10/20 [50%] vs. 5/33 [15%]; P = 0.002). Transmural LGE was predominantly observed in ATTR patients (23/33 [70%] vs. 2/20 [10%]; P < 0.001). The diagnostic performance of T2 mapping to differentiate between AL and ATTR amyloidosis was further increased with the inclusion of LGE patterns [AUC: 0.96, 95% CI: (0.86-0.99); P = 0.05]., Conclusion: ECV differentiates cardiac amyloidosis from other causes of LVH. T2 mapping combined with LGE differentiates AL from ATTR amyloidosis with high accuracy on a patient level., Competing Interests: Conflict of interest: None declared., (© The Author(s) 2024. Published by Oxford University Press on behalf of the European Society of Cardiology. All rights reserved. For commercial re-use, please contact reprints@oup.com for reprints and translation rights for reprints. All other permissions can be obtained through our RightsLink service via the Permissions link on the article page on our site—for further information please contact journals.permissions@oup.com.)
- Published
- 2024
- Full Text
- View/download PDF
10. Fetal cardiovascular magnetic resonance feature tracking myocardial strain analysis in congenital heart disease.
- Author
-
Vollbrecht TM, Hart C, Katemann C, Isaak A, Pieper CC, Kuetting D, Attenberger U, Geipel A, Strizek B, and Luetkens JA
- Abstract
Background: Cardiovascular magnetic resonance (CMR) is an emerging imaging modality for assessing the anatomy and function of the fetal heart in congenital heart disease (CHD). This study aimed to evaluate myocardial strain using fetal CMR feature tracking (FT) in different subtypes of CHD., Methods: Fetal CMR FT analysis was retrospectively performed on four-chamber cine images acquired with Doppler ultrasound gating at 3T. Left ventricular (LV) global longitudinal strain (GLS), LV global radial strain (GRS), LV global longitudinal systolic strain rate, and right ventricular (RV) GLS were quantified using dedicated software optimized for fetal strain analysis. Analysis was performed in normal fetuses and different CHD subtypes (d-transposition of the great arteries [dTGA], hypoplastic left heart syndrome [HLHS], coarctation of the aorta [CoA], tetralogy of Fallot [TOF], RV-dominant atrioventricular septal defect [AVSD], and critical pulmonary stenosis or atresia [PS/PA]). Analysis of variance with Tukey post-hoc test was used for group comparisons., Results: A total of 60 fetuses were analyzed (8/60 (13%) without CHD, 52/60 (87%) with CHD). Myocardial strain was successfully assessed in 113/120 ventricles (94%). Compared to controls, LV GLS was significantly reduced in fetuses with HLHS (-18.6±2.7% vs -6.2±5.6%; p<0.001) and RV-dominant AVSD (-18.6±2.7% vs -7.7±5.0%; p = 0.003) and higher in fetuses with CoA (-18.6±2.7% vs -25.0±4.3%; p = 0.038). LV GRS was significantly reduced in fetuses with HLHS (25.7±7.5% vs 11.4±9.7%; p = 0.024). Compared to controls, RV GRS was significantly reduced in fetuses with PS/PA (-16.1±2.8% vs -8.3±4.2%; p = 0.007). Across all strain parameters, no significant differences were present between controls and fetuses diagnosed with dTGA and TOF., Conclusion: Fetal myocardial strain assessment with CMR FT in CHD is feasible. Distinct differences are present between various types of CHD, suggesting potential implications for clinical decision-making and prognostication in fetal CHD., Competing Interests: Declaration of competing interests The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper., (Copyright © 2024 The Author(s). Published by Elsevier Inc. All rights reserved.)
- Published
- 2024
- Full Text
- View/download PDF
11. Intra-individual comparison of epicardial adipose tissue characteristics on coronary CT angiography between photon-counting detector and energy-integrating detector CT systems.
- Author
-
Kravchenko D, Vecsey-Nagy M, Tremamunno G, Schoepf UJ, O'Doherty J, Luetkens JA, Kuetting D, Isaak A, Hagar MT, Emrich T, and Varga-Szemes A
- Abstract
Purpose: To explore the potential differences in epicardial adipose tissue (EAT) volume and attenuation measurements between photon-counting detector (PCD) and energy-integrating detector (EID)-CT systems., Methods: Fifty patients (mean age 69 ± 8 years, 41 male [82 %]) were prospectively enrolled for a research coronary CT angiography (CCTA) on a PCD-CT within 30 days after clinical EID-based CCTA. EID-CT acquisitions were reconstructed using a Bv40 kernel at 0.6 mm slice thickness. The PCD-CT acquisition was reconstructed at a down-sampled resolution (0.6 mm, Bv40; [PCD-DS]) and at ultra-high resolutions (PCD-UHR) with a 0.2 mm slice thickness and Bv40, Bv48, and Bv64 kernels. EAT segmentation was performed semi-automatically at about 1 cm intervals and interpolated to cover the whole epicardium within a threshold of -190 to -30 HU. A subgroup analysis was performed based on quartile groups created from EID-CT data and PCD-UHR
Bv48 data. Differences were measured using repeated-measures ANOVA and the Friedman test. Correlations were tested using Pearson's and Spearman's rho, and agreement using Bland-Altman plots., Results: EAT volumes significantly differed between some reconstructions (e.g., Eid-Ct: 138 ml [IQR 100, 188]; PCD-DS: 147 ml [110, 206]; P<0.001). Overall, correlations between PCD-UHR and EID-CT EAT volumes were excellent, e.g. PCD-UHRBv48 : r: 0.976 (95 % CI: 0.958, 0.987); P<0.001; with good agreement (mean bias: -9.5 ml; limits of agreement [LoA]: -40.6, 21.6). On the other hand, correlations regarding EAT attenuation was moderate, e.g. PCD-UHRBV48 : r: 0.655 (95 % CI: 0.461, 0.790); P<0.001; mean bias: 6.5 HU; LoA: -2.0, 15.0., Conclusion: EAT attenuation and volume measurements demonstrated different absolute values between PCD-UHR, PCD-DS as well as EID-CT reconstructions, but showed similar tendencies on an intra-individual level. New protocols and threshold ranges need to be developed to allow comparison between PCD-CT and EID-CT data., Competing Interests: Declaration of competing interest The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: UJS receives institutional research support and / or personal fees from Bayer, Bracco, Elucid Bioimaging, Guerbet, HeartFlow, Keya Medical, and Siemens. AVS receives institutional research support and / or personal fees from Elucid Bioimaging and Siemens. TE received a speaker fee and travel support from Siemens, institutional research support by Siemens and is a consultant at Circle CVI. JOD is an employee of Siemens., (Copyright © 2024. Published by Elsevier B.V.)- Published
- 2024
- Full Text
- View/download PDF
12. Prevention of cerebral thromboembolism by oral anticoagulation with dabigatran after pulmonary vein isolation for atrial fibrillation: the ODIn-AF trial.
- Author
-
Schrickel JW, Beiert T, Linhart M, Luetkens JA, Schmitz J, Schmid M, Hindricks G, Arentz T, Stellbrink C, Deneke T, Bogossian H, Sause A, Steven D, Gonska BD, Rudic B, Lewalter T, Zabel M, Geisler T, Schumacher B, Jung W, Kleemann T, Luik A, Veltmann C, Coenen M, and Nickenig G
- Subjects
- Humans, Male, Female, Prospective Studies, Middle Aged, Administration, Oral, Aged, Treatment Outcome, Intracranial Embolism prevention & control, Intracranial Embolism etiology, Intracranial Embolism epidemiology, Antithrombins administration & dosage, Antithrombins adverse effects, Incidence, Follow-Up Studies, Time Factors, Anticoagulants administration & dosage, Anticoagulants adverse effects, Atrial Fibrillation complications, Atrial Fibrillation diagnosis, Atrial Fibrillation surgery, Dabigatran administration & dosage, Dabigatran adverse effects, Pulmonary Veins surgery, Catheter Ablation methods, Catheter Ablation adverse effects
- Abstract
Background and Objectives: Long-term oral anticoagulation (OAC) following successful catheter ablation of atrial fibrillation (AF) remains controversial. Prospective data are missing. The ODIn-AF study aimed to evaluate the effect of OAC on the incidence of silent cerebral embolic events and clinically relevant cardioembolic events in patients at intermediate to high risk for embolic events, free from AF after pulmonary vein isolation (PVI)., Methods: This prospective, randomized, multicenter, open-label, blinded endpoint interventional trial enrolled patients who were scheduled for PVI to treat paroxysmal or persistent AF. Six months after PVI, AF-free patients were randomized to receive either continued OAC with dabigatran or no OAC. The primary endpoint was the incidence of new silent micro- and macro-embolic lesions detected on brain MRI at 12 months of follow-up compared to baseline. Safety analysis included bleedings, clinically evident cardioembolic, and serious adverse events (SAE)., Results: Between 2015 and 2021, 200 patients were randomized into 2 study arms (on OAC: n = 99, off OAC: n = 101). There was no significant difference in the occurrence of new cerebral microlesions between the on OAC and off OAC arm [2 (2%) versus 0 (0%); P = 0.1517] after 12 months. MRI showed no new macro-embolic lesion, no clinical apparent strokes were present in both groups. SAE were more frequent in the OAC arm [on OAC n = 34 (31.8%), off OAC n = 18 (19.4%); P = 0.0460]; bleedings did not differ., Conclusion: Discontinuation of OAC after successful PVI was not found to be associated with an elevated risk of cerebral embolic events compared with continued OAC after a follow-up of 12 months., (© 2023. The Author(s).)
- Published
- 2024
- Full Text
- View/download PDF
13. Generative Pre-trained Transformer 4 analysis of cardiovascular magnetic resonance reports in suspected myocarditis: A multicenter study.
- Author
-
Kaya K, Gietzen C, Hahnfeldt R, Zoubi M, Emrich T, Halfmann MC, Sieren MM, Elser Y, Krumm P, Brendel JM, Nikolaou K, Haag N, Borggrefe J, Krüchten RV, Müller-Peltzer K, Ehrengut C, Denecke T, Hagendorff A, Goertz L, Gertz RJ, Bunck AC, Maintz D, Persigehl T, Lennartz S, Luetkens JA, Jaiswal A, Iuga AI, Pennig L, and Kottlors J
- Abstract
Background: Diagnosing myocarditis relies on multimodal data, including cardiovascular magnetic resonance (CMR), clinical symptoms, and blood values. The correct interpretation and integration of CMR findings require radiological expertise and knowledge. We aimed to investigate the performance of Generative Pre-trained Transformer 4 (GPT-4), a large language model, for report-based medical decision-making in the context of cardiac MRI for suspected myocarditis., Methods: This retrospective study includes CMR reports from 396 patients with suspected myocarditis and eight centers, respectively. CMR reports and patient data including blood values, age, and further clinical information were provided to GPT-4 and radiologists with 1 (resident 1), 2 (resident 2), and 4 years (resident 3) of experience in CMR and knowledge of the 2018 Lake Louise Criteria. The final impression of the report regarding the radiological assessment of whether myocarditis is present or not was not provided. The performance of Generative pre-trained transformer 4 (GPT-4) and the human readers were compared to a consensus reading (two board-certified radiologists with 8 and 10 years of experience in CMR). Sensitivity, specificity, and accuracy were calculated., Results: GPT-4 yielded an accuracy of 83%, sensitivity of 90%, and specificity of 78%, which was comparable to the physician with 1 year of experience (R1: 86%, 90%, 84%, p = 0.14) and lower than that of more experienced physicians (R2: 89%, 86%, 91%, p = 0.007 and R3: 91%, 85%, 96%, p < 0.001). GPT-4 and human readers showed a higher diagnostic performance when results from T1- and T2-mapping sequences were part of the reports, for residents 1 and 3 with statistical significance (p = 0.004 and p = 0.02, respectively)., Conclusion: GPT-4 yielded good accuracy for diagnosing myocarditis based on CMR reports in a large dataset from multiple centers and therefore holds the potential to serve as a diagnostic decision-supporting tool in this capacity, particularly for less experienced physicians. Further studies are required to explore the full potential and elucidate educational aspects of the integration of large language models in medical decision-making., Competing Interests: Declaration of competing interests The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: David Maintz received speaker’s honoraria from Philips Healthcare. Jan Borggrefe received speaker’s honoraria from Siemens Healthineers. Simon Lennartz is a member of Editorial Board of Radiology and a Senior Deputy Editor of Radiology in Training. Otherwise, the authors declare no conflicts of interest and had full control over all data, and guarantee correctness., (Copyright © 2024 The Author(s). Published by Elsevier Inc. All rights reserved.)
- Published
- 2024
- Full Text
- View/download PDF
14. CT-derived Epicardial Adipose Tissue Inflammation Predicts Outcome in Patients Undergoing Transcatheter Aortic Valve Replacement.
- Author
-
Salam B, Al-Kassou B, Weinhold L, Sprinkart AM, Nowak S, Theis M, Schmid M, Al Zaidi M, Weber M, Pieper CC, Kuetting D, Shamekhi J, Nickenig G, Attenberger U, Zimmer S, and Luetkens JA
- Subjects
- Humans, Female, Male, Retrospective Studies, Aged, 80 and over, Aged, Predictive Value of Tests, Aortic Valve diagnostic imaging, Aortic Valve surgery, Risk Factors, Epicardial Adipose Tissue, Transcatheter Aortic Valve Replacement methods, Adipose Tissue diagnostic imaging, Pericardium diagnostic imaging, Tomography, X-Ray Computed methods, Inflammation diagnostic imaging, Aortic Valve Stenosis surgery, Aortic Valve Stenosis diagnostic imaging
- Abstract
Purpose: Inflammatory changes in epicardial (EAT) and pericardial adipose tissue (PAT) are associated with increased overall cardiovascular risk. Using routine, preinterventional cardiac CT data, we examined the predictive value of quantity and quality of EAT and PAT for outcome after transcatheter aortic valve replacement (TAVR)., Materials and Methods: Cardiac CT data of 1197 patients who underwent TAVR at the in-house heart center between 2011 and 2020 were retrospectively analyzed. The amount and density of EAT and PAT were quantified from single-slice CT images at the level of the aortic valve. Using established risk scores and known independent risk factors, a clinical benchmark model (BMI, Chronic kidney disease stage, EuroSCORE 2, STS Prom, year of intervention) for outcome prediction (2-year mortality) after TAVR was established. Subsequently, we tested whether the additional inclusion of area and density values of EAT and PAT in the clinical benchmark model improved prediction. For this purpose, the cohort was divided into a training (n=798) and a test cohort (n=399)., Results: Within the 2-year follow-up, 264 patients died. In the training cohort, particularly the addition of EAT density to the clinical benchmark model showed a significant association with outcome (hazard ratio 1.04, 95% CI: 1.01-1.07; P =0.013). In the test cohort, the outcome prediction of the clinical benchmark model was also significantly improved with the inclusion of EAT density (c-statistic: 0.589 vs. 0.628; P =0.026)., Conclusions: EAT density as a surrogate marker of EAT inflammation was associated with 2-year mortality after TAVR and may improve outcome prediction independent of established risk parameters., Competing Interests: The authors declare no conflict of interest., (Copyright © 2024 Wolters Kluwer Health, Inc. All rights reserved.)
- Published
- 2024
- Full Text
- View/download PDF
15. SCMR expert consensus statement for cardiovascular magnetic resonance of patients with a cardiac implantable electronic device.
- Author
-
Kim D, Collins JD, White JA, Hanneman K, Lee DC, Patel AR, Hu P, Litt H, Weinsaft JW, Davids R, Mukai K, Ng MY, Luetkens JA, Roguin A, Rochitte CE, Woodard PK, Manisty C, Zareba KM, Mont L, Bogun F, Ennis DB, Nazarian S, Webster G, and Stojanovska J
- Subjects
- Humans, Risk Factors, Risk Assessment, Clinical Decision-Making, Arrhythmias, Cardiac therapy, Arrhythmias, Cardiac diagnosis, Arrhythmias, Cardiac diagnostic imaging, Arrhythmias, Cardiac physiopathology, Electric Countershock instrumentation, Electric Countershock adverse effects, Heart Diseases diagnostic imaging, Heart Diseases therapy, Consensus, Defibrillators, Implantable, Predictive Value of Tests, Pacemaker, Artificial, Magnetic Resonance Imaging standards, Magnetic Resonance Imaging adverse effects
- Abstract
Cardiovascular magnetic resonance (CMR) is a proven imaging modality for informing diagnosis and prognosis, guiding therapeutic decisions, and risk stratifying surgical intervention. Patients with a cardiac implantable electronic device (CIED) would be expected to derive particular benefit from CMR given high prevalence of cardiomyopathy and arrhythmia. While several guidelines have been published over the last 16 years, it is important to recognize that both the CIED and CMR technologies, as well as our knowledge in MR safety, have evolved rapidly during that period. Given increasing utilization of CIED over the past decades, there is an unmet need to establish a consensus statement that integrates latest evidence concerning MR safety and CIED and CMR technologies. While experienced centers currently perform CMR in CIED patients, broad availability of CMR in this population is lacking, partially due to limited availability of resources for programming devices and appropriate monitoring, but also related to knowledge gaps regarding the risk-benefit ratio of CMR in this growing population. To address the knowledge gaps, this SCMR Expert Consensus Statement integrates consensus guidelines, primary data, and opinions from experts across disparate fields towards the shared goal of informing evidenced-based decision-making regarding the risk-benefit ratio of CMR for patients with CIEDs., Competing Interests: Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper., (Copyright © 2024 The Authors. Published by Elsevier Inc. All rights reserved.)
- Published
- 2024
- Full Text
- View/download PDF
16. Generative Pre-trained Transformer 4 makes cardiovascular magnetic resonance reports easy to understand.
- Author
-
Salam B, Kravchenko D, Nowak S, Sprinkart AM, Weinhold L, Odenthal A, Mesropyan N, Bischoff LM, Attenberger U, Kuetting DL, Luetkens JA, and Isaak A
- Subjects
- Humans, Reproducibility of Results, Observer Variation, Health Literacy, Patient Education as Topic, Cardiovascular Diseases diagnostic imaging, Female, Male, Predictive Value of Tests, Comprehension, Magnetic Resonance Imaging
- Abstract
Background: Patients are increasingly using Generative Pre-trained Transformer 4 (GPT-4) to better understand their own radiology findings., Purpose: To evaluate the performance of GPT-4 in transforming cardiovascular magnetic resonance (CMR) reports into text that is comprehensible to medical laypersons., Methods: ChatGPT with GPT-4 architecture was used to generate three different explained versions of 20 various CMR reports (n = 60) using the same prompt: "Explain the radiology report in a language understandable to a medical layperson". Two cardiovascular radiologists evaluated understandability, factual correctness, completeness of relevant findings, and lack of potential harm, while 13 medical laypersons evaluated the understandability of the original and the GPT-4 reports on a Likert scale (1 "strongly disagree", 5 "strongly agree"). Readability was measured using the Automated Readability Index (ARI). Linear mixed-effects models (values given as median [interquartile range]) and intraclass correlation coefficient (ICC) were used for statistical analysis., Results: GPT-4 reports were generated on average in 52 s ± 13. GPT-4 reports achieved a lower ARI score (10 [9-12] vs 5 [4-6]; p < 0.001) and were subjectively easier to understand for laypersons than original reports (1 [1] vs 4 [4,5]; p < 0.001). Eighteen out of 20 (90%) standard CMR reports and 2/60 (3%) GPT-generated reports had an ARI score corresponding to the 8th grade level or higher. Radiologists' ratings of the GPT-4 reports reached high levels for correctness (5 [4, 5]), completeness (5 [5]), and lack of potential harm (5 [5]); with "strong agreement" for factual correctness in 94% (113/120) and completeness of relevant findings in 81% (97/120) of reports. Test-retest agreement for layperson understandability ratings between the three simplified reports generated from the same original report was substantial (ICC: 0.62; p < 0.001). Interrater agreement between radiologists was almost perfect for lack of potential harm (ICC: 0.93, p < 0.001) and moderate to substantial for completeness (ICC: 0.76, p < 0.001) and factual correctness (ICC: 0.55, p < 0.001)., Conclusion: GPT-4 can reliably transform complex CMR reports into more understandable, layperson-friendly language while largely maintaining factual correctness and completeness, and can thus help convey patient-relevant radiology information in an easy-to-understand manner., Competing Interests: Declaration of competing interests The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: Alexander Isaak reports financial support was provided by BONFOR Research Commission of the Medical Faculty Bonn. The other authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper., (Copyright © 2024 The Author(s). Published by Elsevier Inc. All rights reserved.)
- Published
- 2024
- Full Text
- View/download PDF
17. 3D-Volumetric Shunt Measurement for Detection of High-Risk Esophageal Varices in Liver Cirrhosis.
- Author
-
Glückert K, Decker A, Meier JA, Nowak S, Sanoubara F, Gödiker J, Reinartz Groba SN, Kimmann M, Luetkens JA, Chang J, Sprinkart AM, and Praktiknjo M
- Abstract
Background and Objectives: Esophageal varices (EV) and variceal hemorrhages are major causes of mortality in liver cirrhosis patients. Detecting EVs early is crucial for effective management. Computed tomography (CT) scans, commonly performed for various liver-related indications, provide an opportunity for non-invasive EV assessment. However, previous CT studies focused on variceal diameter, neglecting the three-dimensional (3D) nature of varices and shunt vessels. This study aims to evaluate the potential of 3D volumetric shunt-vessel measurements from routine CT scans for detecting high-risk esophageal varices in portal hypertension. Methods: 3D volumetric measurements of esophageal varices were conducted using routine CT scans and compared to endoscopic variceal grading. Receiver operating characteristic (ROC) analyses were performed to determine the optimal cutoff value for identifying high-risk varices based on shunt volume. The study included 142 patients who underwent both esophagogastroduodenoscopy (EGD) and contrast-enhanced CT within six months. Results: The study established a cutoff value for identifying high-risk varices. The CT measurements exhibited a significant correlation with endoscopic EV grading (correlation coefficient r = 0.417, p < 0.001). A CT cutoff value of 2060 mm
3 for variceal volume showed a sensitivity of 72.1% and a specificity of 65.5% for detecting high-risk varices during endoscopy. Conclusions: This study demonstrates the feasibility of opportunistically measuring variceal volumes from routine CT scans. CT volumetry for assessing EVs may have prognostic value, especially in cirrhosis patients who are not suitable candidates for endoscopy.- Published
- 2024
- Full Text
- View/download PDF
18. Radiologists' perspectives on the workflow integration of an artificial intelligence-based computer-aided detection system: A qualitative study.
- Author
-
Wenderott K, Krups J, Luetkens JA, and Weigl M
- Subjects
- Male, Humans, Workflow, Radiologists, Computers, Artificial Intelligence, Software
- Abstract
In healthcare, artificial intelligence (AI) is expected to improve work processes, yet most research focuses on the technical features of AI rather than its real-world clinical implementation. To evaluate the implementation process of an AI-based computer-aided detection system (AI-CAD) for prostate MRI readings, we interviewed German radiologists in a pre-post design. We embedded our findings in the Model of Workflow Integration and the Technology Acceptance Model to analyze workflow effects, facilitators, and barriers. The most prominent barriers were: (i) a time delay in the work process, (ii) additional work steps to be taken, and (iii) an unstable performance of the AI-CAD. Most frequently named facilitators were (i) good self-organization, and (ii) good usability of the software. Our results underline the importance of a holistic approach to AI implementation considering the sociotechnical work system and provide valuable insights into key factors of the successful adoption of AI technologies in work systems., Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper., (Copyright © 2024 The Authors. Published by Elsevier Ltd.. All rights reserved.)
- Published
- 2024
- Full Text
- View/download PDF
19. Fetal Cardiac MRI Using Doppler US Gating: Emerging Technology and Clinical Implications.
- Author
-
Vollbrecht TM, Bissell MM, Kording F, Geipel A, Isaak A, Strizek BS, Hart C, Barker AJ, and Luetkens JA
- Subjects
- Female, Pregnancy, Humans, Radiography, Fetal Heart diagnostic imaging, Technology, Prenatal Care, Magnetic Resonance Imaging
- Abstract
Fetal cardiac MRI using Doppler US gating is an emerging technique to support prenatal diagnosis of congenital heart disease and other cardiovascular abnormalities. Analogous to postnatal electrocardiographically gated cardiac MRI, this technique enables directly gated MRI of the fetal heart throughout the cardiac cycle, allowing for immediate data reconstruction and review of image quality. This review outlines the technical principles and challenges of cardiac MRI with Doppler US gating, such as loss of gating signal due to fetal movement. A practical workflow of patient preparation for the use of Doppler US-gated fetal cardiac MRI in clinical routine is provided. Currently applied MRI sequences (ie, cine or four-dimensional flow imaging), with special consideration of technical adaptations to the fetal heart, are summarized. The authors provide a literature review on the clinical benefits of Doppler US-gated fetal cardiac MRI for gaining additional diagnostic information on cardiovascular malformations and fetal hemodynamics. Finally, future perspectives of Doppler US-gated fetal cardiac MRI and further technical developments to reduce acquisition times and eliminate sources of artifacts are discussed. Keywords: MR Fetal, Ultrasound Doppler, Cardiac, Heart, Congenital, Obstetrics, Fetus Supplemental material is available for this article. © RSNA, 2024.
- Published
- 2024
- Full Text
- View/download PDF
20. Unveiling Subclinical Cardiovascular Disease in HIV with Advanced Cardiovascular Imaging.
- Author
-
Luetkens JA and Bischoff LM
- Published
- 2024
- Full Text
- View/download PDF
21. Interventional treatment of refractory non-traumatic chylous effusions in patients with lymphoproliferative disorders.
- Author
-
Wagenpfeil J, Hoß K, Henkel A, Kütting D, Luetkens JA, Feldmann G, Brossart P, Attenberger UI, and Pieper CC
- Subjects
- Humans, Male, Aged, Treatment Outcome, Chylothorax diagnostic imaging, Chylothorax therapy, Chylous Ascites therapy, Lymphoproliferative Disorders, Lymphatic Abnormalities
- Abstract
To report results of interventional treatment of refractory non-traumatic abdomino-thoracic chylous effusions in patients with lymphoproliferative disorders. 17 patients (10 male; mean age 66.7 years) with lymphoproliferative disorders suffered from non-traumatic chylous effusions (chylothorax n = 11, chylous ascites n = 3, combined abdomino-thoracic effusion n = 3) refractory to chemotherapy and conservative therapy. All underwent x-ray lymphangiography with iodized-oil to evaluate for and at the same time treat lymphatic abnormalities (leakage, chylo-lymphatic reflux with/without obstruction of central drainage). In patients with identifiable active leakage additional lymph-vessel embolization was performed. Resolution of effusions was deemed as clinical success. Lymphangiography showed reflux in 8/17 (47%), leakage in 2/17 (11.8%), combined leakage and reflux in 3/17 (17.6%), lymphatic obstruction in 2/17 (11.8%) and normal findings in 2/17 cases (11.8%). 12/17 patients (70.6%) were treated by lymphangiography alone; 5/17 (29.4%) with leakage received additional embolization (all technically successful). Effusions resolved in 15/17 cases (88.2%); 10/12 (83.3%) resolved after lymphangiography alone and in 5/5 patients (100%) after embolization. Time-to-resolution of leakage was significantly shorter after embolization (within one day in all cases) than lymphangiography (median 9 [range 4-30] days; p = 0.001). There was no recurrence of symptoms or post-interventional complications during follow-up (median 445 [40-1555] days). Interventional-radiological treatment of refractory, non-traumatic lymphoma-induced chylous effusions is safe and effective. Lymphangiography identifies lymphatic abnormalities in the majority of patients and leads to resolution of effusions in > 80% of cases. Active leakage is found in only a third of patients and can be managed by additional embolization., (© 2024. The Author(s).)
- Published
- 2024
- Full Text
- View/download PDF
22. Image quality of abdominal photon-counting CT with reduced contrast media dose: Evaluation of reduced contrast media protocols during the COVID19 pandemic supply shortage.
- Author
-
Layer YC, Isaak A, Mesropyan N, Kupczyk PA, Luetkens JA, Dell T, Attenberger UI, and Kuetting D
- Abstract
Rationale and Objectives: Aim of this study was to assess the impact of contrast media dose (CMD) reduction on diagnostic quality of photon-counting detector CT (PCD-CT) and energy-integrating detector CT (EID-CT)., Methods: CT scans of the abdominal region with differing CMD acquired in portal venous phase on a PCD-CT were included and compared to EID-CT scans. Diagnostic quality and contrast intensity were rated. Additionally, readers had to assign the scans to reduced or regular CMD. Regions-of-interest (ROIs) were placed in defined segments of portal vein, inferior vena cava, liver, spleen, kidneys, abdominal aorta and muscular tissue. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated., Results: Overall 158 CT scans performed on a PCD-CT and 68 examinations on an EID-CT were analyzed. Overall diagnostic quality showed no significant differences for PCD-CT with standard CMD which scored a median 5 (IQR:5-5) and PCD-CT with 70% CMD scoring 5 (4-5). (For PCD-CT, 71.69% of the examinations with reduced CMD were assigned to regular CMD by the readers, for EID-CT 9.09%. Averaged for all measurements SNR for 50% CMD was reduced by 19% in PCD-CT (EID-CT 34%) and CNR by 48% (EID-CT 56%). Virtual monoenergetic images (VMI)
50keV for PCD-CT images acquired with 50% CMD showed an increase in SNR by 72% and CNR by 153%., Conclusions: Diagnostic interpretability of PCD-CT examinations with reduction of up to 50% CMD is maintained. PCD-CT deducted scans especially with 70% CMD were often not recognized as CMD reduced scans. Compared to EID-CT less decline in SNR and CNR is observed for CMD reduced PCD-CT images. Employing VMI50keV for CMD-reduced PCD-CT images compensated for the effects., Competing Interests: The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: Yannik Christian Layer reports a relationship with 10.13039/501100004830Siemens Healthcare AG that includes: funding grants., (© 2024 The Authors.)- Published
- 2024
- Full Text
- View/download PDF
23. Optical Flow-Guided Cine MRI Segmentation With Learned Corrections.
- Author
-
Ortiz-Gonzalez A, Kobler E, Simon S, Bischoff L, Nowak S, Isaak A, Block W, Sprinkart AM, Attenberger U, Luetkens JA, Bayro-Corrochano E, and Effland A
- Subjects
- Humans, Image Processing, Computer-Assisted methods, Heart diagnostic imaging, Heart Ventricles, Magnetic Resonance Imaging methods, Heart Atria, Magnetic Resonance Imaging, Cine methods, Optic Flow
- Abstract
In cardiac cine magnetic resonance imaging (MRI), the heart is repeatedly imaged at numerous time points during the cardiac cycle. Frequently, the temporal evolution of a certain region of interest such as the ventricles or the atria is highly relevant for clinical diagnosis. In this paper, we devise a novel approach that allows for an automatized propagation of an arbitrary region of interest (ROI) along the cardiac cycle from respective annotated ROIs provided by medical experts at two different points in time, most frequently at the end-systolic (ES) and the end-diastolic (ED) cardiac phases. At its core, a 3D TV- L
1 -based optical flow algorithm computes the apparent motion of consecutive MRI images in forward and backward directions. Subsequently, the given terminal annotated masks are propagated by this bidirectional optical flow in 3D, which results, however, in improper initial estimates of the segmentation masks due to numerical inaccuracies. These initially propagated segmentation masks are then refined by a 3D U-Net-based convolutional neural network (CNN), which was trained to enforce consistency with the forward and backward warped masks using a novel loss function. Moreover, a penalization term in the loss function controls large deviations from the initial segmentation masks. This method is benchmarked both on a new dataset with annotated single ventricles containing patients with severe heart diseases and on a publicly available dataset with different annotated ROIs. We emphasize that our novel loss function enables fine-tuning the CNN on a single patient, thereby yielding state-of-the-art results along the complete cardiac cycle.- Published
- 2024
- Full Text
- View/download PDF
24. Outcome of transarterial radioembolization in patients with hepatocellular carcinoma as a first-line interventional therapy and after a previous transarterial chemoembolization.
- Author
-
Wagenpfeil J, Kupczyk PA, Bruners P, Siepmann R, Guendel E, Luetkens JA, Isaak A, Meyer C, Kuetting F, Pieper CC, Attenberger UI, and Kuetting D
- Abstract
Purpose: Due to a lack of data, there is an ongoing debate regarding the optimal frontline interventional therapy for unresectable hepatocellular carcinoma (HCC). The aim of the study is to compare the results of transarterial radioembolization (TARE) as the first-line therapy and as a subsequent therapy following prior transarterial chemoembolization (TACE) in these patients., Methods: A total of 83 patients were evaluated, with 38 patients having undergone at least one TACE session prior to TARE [27 male; mean age 67.2 years; 68.4% stage Barcelona clinic liver cancer (BCLC) B, 31.6% BCLC C]; 45 patients underwent primary TARE (33 male; mean age 69.9 years; 40% BCLC B, 58% BCLC C). Clinical [age, gender, BCLC stage, activity in gigabecquerel (GBq), Child-Pugh status, portal vein thrombosis, tumor volume] and procedural [overall survival (OS), local tumor control (LTC), and progression-free survival (PFS)] data were compared. A regression analysis was performed to evaluate OS, LTC, and PFS., Results: No differences were found in OS (95% CI: 1.12, P = 0.289), LTC (95% CI: 0.003, P = 0.95), and PFS (95% CI: 0.4, P = 0.525). The regression analysis revealed a relationship between Child-Pugh score ( P = 0.005), size of HCC lesions (>10 cm) ( P = 0.022), and OS; neither prior TACE (Child-Pugh B patients; 95% CI: 0.120, P = 0.729) nor number of lesions (>10; 95% CI: 2.930, P = 0.087) correlated with OS., Conclusion: Prior TACE does not affect the outcome of TARE in unresectable HCC., Competing Interests: The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest., (© 2024 Wagenpfeil, Kupczyk, Bruners, Siepmann, Guendel, Luetkens, Isaak, Meyer, Kuetting, Pieper, Attenberger and Kuetting.)
- Published
- 2024
- Full Text
- View/download PDF
25. Deep learning denoising reconstruction for improved image quality in fetal cardiac cine MRI.
- Author
-
Vollbrecht TM, Hart C, Zhang S, Katemann C, Sprinkart AM, Isaak A, Attenberger U, Pieper CC, Kuetting D, Geipel A, Strizek B, and Luetkens JA
- Abstract
Purpose: This study aims to evaluate deep learning (DL) denoising reconstructions for image quality improvement of Doppler ultrasound (DUS)-gated fetal cardiac MRI in congenital heart disease (CHD)., Methods: Twenty-five fetuses with CHD (mean gestational age: 35 ± 1 weeks) underwent fetal cardiac MRI at 3T. Cine imaging was acquired using a balanced steady-state free precession (bSSFP) sequence with Doppler ultrasound gating. Images were reconstructed using both compressed sensing (bSSFP CS) and a pre-trained convolutional neural network trained for DL denoising (bSSFP DL). Images were compared qualitatively based on a 5-point Likert scale (from 1 = non-diagnostic to 5 = excellent) and quantitatively by calculating the apparent signal-to-noise ratio (aSNR) and contrast-to-noise ratio (aCNR). Diagnostic confidence was assessed for the atria, ventricles, foramen ovale, valves, great vessels, aortic arch, and pulmonary veins., Results: Fetal cardiac cine MRI was successful in 23 fetuses (92%), with two studies excluded due to extensive fetal motion. The image quality of bSSFP DL cine reconstructions was rated superior to standard bSSFP CS cine images in terms of contrast [3 (interquartile range: 2-4) vs. 5 (4-5), P < 0.001] and endocardial edge definition [3 (2-4) vs. 4 (4-5), P < 0.001], while the extent of artifacts was found to be comparable [4 (3-4.75) vs. 4 (3-4), P = 0.40]. bSSFP DL images had higher aSNR and aCNR compared with the bSSFP CS images (aSNR: 13.4 ± 6.9 vs. 8.3 ± 3.6, P < 0.001; aCNR: 26.6 ± 15.8 vs. 14.4 ± 6.8, P < 0.001). Diagnostic confidence of the bSSFP DL images was superior for the evaluation of cardiovascular structures (e.g., atria and ventricles: P = 0.003)., Conclusion: DL image denoising provides superior quality for DUS-gated fetal cardiac cine imaging of CHD compared to standard CS image reconstruction., Competing Interests: Authors SZ and CK were employed by Philips GmbH Market DACH. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest. The authors declared that they were editorial board members of Frontiers at the time of submission. This had no impact on the peer review process or the final decision., (© 2024 Vollbrecht, Hart, Zhang, Katemann, Sprinkart, Isaak, Attenberger, Pieper, Kuetting, Geipel, Strizek and Luetkens.)
- Published
- 2024
- Full Text
- View/download PDF
26. Use of virtual monoenergetic images for reduction of extensive dental implant associated artifacts in photon-counting detector CT.
- Author
-
Layer YC, Mesropyan N, Kupczyk PA, Luetkens JA, Isaak A, Dell T, Ernst BP, Attenberger UI, and Kuetting D
- Subjects
- Artifacts, Retrospective Studies, Tomography, X-Ray Computed methods, Cheek, Signal-To-Noise Ratio, Radiographic Image Interpretation, Computer-Assisted methods, Dental Implants
- Abstract
Aim of this study was to assess the impact of virtual monoenergetic images (VMI) on dental implant artifacts in photon-counting detector computed tomography (PCD-CT) compared to standard reconstructed polychromatic images (PI). 30 scans with extensive (≥ 5 dental implants) dental implant-associated artifacts were retrospectively analyzed. Scans were acquired during clinical routine on a PCD-CT. VMI were reconstructed for 100-190 keV (10 keV steps) and compared to PI. Artifact extent and assessment of adjacent soft tissue were rated using a 5-point Likert grading scale for qualitative assessment. Quantitative assessment was performed using ROIs in most pronounced hypodense and hyperdense artifacts, artifact-impaired soft tissue, artifact-free fat and muscle tissue. A corrected attenuation was calculated as difference between artifact-impaired tissue and tissue without artifacts. Qualitative assessment of soft palate and cheeks improved for all VMI compared to PI (Median PI: 1 (Range: 1-3) and 1 (1-3); e.g. VMI
130 keV 2 (1-5); p < 0.0001 and 2 (1-4); p < 0.0001). In quantitative assessment, VMI130 keV showed best results with a corrected attenuation closest to 0 (PI: 30.48 ± 98.16; VMI130 keV : - 0.55 ± 73.38; p = 0.0026). Overall, photon-counting deducted VMI reduce the extent of dental implant-associated artifacts. VMI of 130 keV showed best results and are recommended to support head and neck CT scans., (© 2024. The Author(s).)- Published
- 2024
- Full Text
- View/download PDF
27. Prospective effects of an artificial intelligence-based computer-aided detection system for prostate imaging on routine workflow and radiologists' outcomes.
- Author
-
Wenderott K, Krups J, Luetkens JA, Gambashidze N, and Weigl M
- Subjects
- Male, Humans, Magnetic Resonance Imaging, Prostate, Workflow, Radiologists, Computers, Artificial Intelligence, Prostatic Neoplasms diagnostic imaging
- Abstract
Objectives: Artificial intelligence (AI) is expected to alleviate the negative consequences of rising case numbers for radiologists. Currently, systematic evaluations of the impact of AI solutions in real-world radiological practice are missing. Our study addresses this gap by investigating the impact of the clinical implementation of an AI-based computer-aided detection system (CAD) for prostate MRI reading on clinicians' workflow, workflow throughput times, workload, and stress., Materials and Methods: CAD was newly implemented into radiology workflow and accompanied by a prospective pre-post study design. We assessed prostate MRI case readings using standardized work observations and questionnaires. The observation period was three months each in a single department. Workflow throughput times, PI-RADS score, CAD usage and radiologists' self-reported workload and stress were recorded. Linear mixed models were employed for effect identification., Results: In data analyses, 91 observed case readings (pre: 50, post: 41) were included. Variation of routine workflow was observed following CAD implementation. A non-significant increase in overall workflow throughput time was associated with CAD implementation (mean 16.99 ± 6.21 vs 18.77 ± 9.69 min, p = .51), along with an increase in diagnostic reading time for high suspicion cases (mean 15.73 ± 4.99 vs 23.07 ± 8.75 min, p = .02). Changes in radiologists' self-reported workload or stress were not found., Conclusion: Implementation of an AI-based detection aid was associated with lower standardization and no effects over time on radiologists' workload or stress. Expectations of AI decreasing the workload of radiologists were not confirmed by our real-world study., Pre-Registration: German register for clinical trials https://drks.de/; DRKS00027391., Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper., (Copyright © 2023 The Author(s). Published by Elsevier B.V. All rights reserved.)
- Published
- 2024
- Full Text
- View/download PDF
28. Deep learning-based assessment of CT markers of sarcopenia and myosteatosis for outcome assessment in patients with advanced pancreatic cancer after high-intensity focused ultrasound treatment.
- Author
-
Nowak S, Kloth C, Theis M, Marinova M, Attenberger UI, Sprinkart AM, and Luetkens JA
- Subjects
- Humans, Male, Retrospective Studies, Muscle, Skeletal diagnostic imaging, Muscle, Skeletal pathology, Prognosis, Tomography, X-Ray Computed methods, Outcome Assessment, Health Care, Sarcopenia complications, Sarcopenia diagnostic imaging, Deep Learning, Pancreatic Neoplasms complications, Pancreatic Neoplasms pathology
- Abstract
Objectives: To evaluate the prognostic value of CT-based markers of sarcopenia and myosteatosis in comparison to the Eastern Cooperative Oncology Group (ECOG) score for survival of patients with advanced pancreatic cancer treated with high-intensity focused ultrasound (HIFU)., Materials and Methods: For 142 retrospective patients, the skeletal muscle index (SMI), skeletal muscle radiodensity (SMRD), fatty muscle fraction (FMF), and intermuscular fat fraction (IMFF) were determined on superior mesenteric artery level in pre-interventional CT. Each marker was tested for associations with sex, age, body mass index (BMI), and ECOG. The prognostic value of the markers was examined in Kaplan-Meier analyses with the log-rank test and in uni- and multivariable Cox proportional hazards (CPH) models., Results: The following significant associations were observed: Male patients had higher BMI and SMI. Patients with lower ECOG had lower BMI and SMI. Patients with BMI lower than 21.8 kg/m
2 (median) also showed lower SMI and IMFF. Patients younger than 63.3 years (median) were found to have higher SMRD, lower FMF, and lower IMFF. In the Kaplan-Meier analysis, significantly lower survival times were observed in patients with higher ECOG or lower SMI. Increased patient risk was observed for higher ECOG, lower BMI, and lower SMI in univariable CPH analyses for 1-, 2-, and 3-year survival. Multivariable CPH analysis for 1-year survival revealed increased patient risk for higher ECOG, lower SMI, lower IMFF, and higher FMF. In multivariable analysis for 2- and 3-year survival, only ECOG and FMF remained significant., Conclusion: CT-based markers of sarcopenia and myosteatosis show a prognostic value for assessment of survival in advanced pancreatic cancer patients undergoing HIFU therapy., Clinical Relevance Statement: The results indicate a greater role of myosteatosis for additional risk assessment beyond clinical scores, as only FMF was associated with long-term survival in multivariable CPH analyses along ECOG and also showed independence to ECOG in group analysis., Key Points: • This study investigates the prognostic value of CT-based markers of sarcopenia and myosteatosis for patients with pancreatic cancer treated with high-intensity focused ultrasound. • Markers for sarcopenia and myosteatosis showed a prognostic value besides clinical assessment of the physical status by the Eastern Cooperative Oncology Group score. In contrast to muscle size measurements, the myosteatosis marker fatty muscle fraction demonstrated independence to the clinical score. • The results indicate that myosteatosis might play a greater role for additional patient risk assessments beyond clinical assessments of physical status., (© 2023. The Author(s).)- Published
- 2024
- Full Text
- View/download PDF
29. Opportunistic CT-derived analysis of fat and muscle tissue composition predicts mortality in patients with cardiogenic shock.
- Author
-
Salam B, Al Zaidi M, Sprinkart AM, Nowak S, Theis M, Kuetting D, Aksoy A, Nickenig G, Attenberger U, Zimmer S, and Luetkens JA
- Subjects
- Humans, Body Composition, Prognosis, Biomarkers, Tomography, X-Ray Computed methods, Retrospective Studies, Shock, Cardiogenic diagnostic imaging, Muscle, Skeletal diagnostic imaging
- Abstract
Prognosis estimation in patients with cardiogenic shock (CS) is important to guide clinical decision making. Aim of this study was to investigate the predictive value of opportunistic CT-derived body composition analysis in CS patients. Amount and density of fat and muscle tissue of 152 CS patients were quantified from single-slice CT images at the level of the intervertebral disc space L3/L4. Multivariable Cox regression and Kaplan-Meier survival analyses were performed to evaluate the predictive value of opportunistically CT-derived body composition parameters on the primary endpoint of 30-day mortality. Within the 30-day follow-up, 90/152 (59.2%) patients died. On multivariable analyses, lactate (Hazard Ratio 1.10 [95% Confidence Interval 1.04-1.17]; p = 0.002) and patient age (HR 1.04 [95% CI 1.01-1.07], p = 0.017) as clinical prognosticators, as well as visceral adipose tissue (VAT) area (HR 1.004 [95% CI 1.002-1.007]; p = 0.001) and skeletal muscle (SM) area (HR 0.987 [95% CI 0.975-0.999]; p = 0.043) as imaging biomarkers remained as independent predictors of 30-day mortality. Kaplan-Meier survival analyses showed significantly increased 30-day mortality in patients with higher VAT area (p = 0.015) and lower SM area (p = 0.035). CT-derived VAT and SM area are independent predictors of dismal outcomes in CS patients and have the potential to emerge as new imaging biomarkers available from routine diagnostic CT., (© 2023. The Author(s).)
- Published
- 2023
- Full Text
- View/download PDF
30. MRI proton density fat fraction for estimation of tumor grade in steatotic hepatocellular carcinoma.
- Author
-
Kupczyk PA, Kurt D, Endler C, Luetkens JA, Kukuk GM, Fronhoffs F, Fischer HP, Attenberger UI, and Pieper CC
- Subjects
- Humans, Liver pathology, Retrospective Studies, Protons, Magnetic Resonance Imaging methods, Liver Cirrhosis pathology, Carcinoma, Hepatocellular complications, Carcinoma, Hepatocellular diagnostic imaging, Carcinoma, Hepatocellular pathology, Non-alcoholic Fatty Liver Disease complications, Non-alcoholic Fatty Liver Disease diagnostic imaging, Liver Neoplasms complications, Liver Neoplasms diagnostic imaging, Liver Neoplasms pathology
- Abstract
Objectives: Image-based detection of intralesional fat in focal liver lesions has been established in diagnostic guidelines as a feature indicative of hepatocellular carcinoma (HCC) and associated with a favorable prognosis. Given recent advances in MRI-based fat quantification techniques, we investigated a possible relationship between intralesional fat content and histologic tumor grade in steatotic HCCs., Methods: Patients with histopathologically confirmed HCC and prior MRI with proton density fat fraction (PDFF) mapping were retrospectively identified. Intralesional fat of HCCs was assessed using an ROI-based analysis and the median fat fraction of steatotic HCCs was compared between tumor grades G1-3 with non-parametric testing. ROC analysis was performed in case of statistically significant differences (p < 0.05). Subgroup analyses were conducted for patients with/without liver steatosis and with/without liver cirrhosis., Results: A total of 57 patients with steatotic HCCs (62 lesions) were eligible for analysis. The median fat fraction was significantly higher for G1 lesions (median [interquartile range], 7.9% [6.0─10.7%]) than for G2 (4.4% [3.2─6.6%]; p = .001) and G3 lesions (4.7% [2.8─7.8%]; p = .036). PDFF was a good discriminator between G1 and G2/3 lesions (AUC .81; cut-off 5.8%, sensitivity 83%, specificity 68%) with comparable results in patients with liver cirrhosis. In patients with liver steatosis, intralesional fat content was higher than in the overall sample, with PDFF performing better in distinguishing between G1 and G2/3 lesions (AUC .92; cut-off 8.8%, sensitivity 83%, specificity 91%)., Conclusions: Quantification of intralesional fat using MRI PDFF mapping allows distinction between well- and less-differentiated steatotic HCCs., Clinical Relevance: PDFF mapping may help optimize precision medicine as a tool for tumor grade assessment in steatotic HCCs. Further investigation of intratumoral fat content as a potential prognostic indicator of treatment response is encouraged., Key Points: • MRI proton density fat fraction mapping enables distinction between well- (G1) and less- (G2 and G3) differentiated steatotic hepatocellular carcinomas. • In a retrospective single-center study with 62 histologically proven steatotic hepatocellular carcinomas, G1 tumors showed a higher intralesional fat content than G2 and G3 tumors (7.9% vs. 4.4% and 4.7%; p = .004). • In liver steatosis, MRI proton density fat fraction mapping was an even better discriminator between G1 and G2/G3 steatotic hepatocellular carcinomas., (© 2023. The Author(s).)
- Published
- 2023
- Full Text
- View/download PDF
31. Direct deep learning-based survival prediction from pre-interventional CT prior to transcatheter aortic valve replacement.
- Author
-
Theis M, Block W, Luetkens JA, Attenberger UI, Nowak S, and Sprinkart AM
- Subjects
- Humans, Female, Aged, Aged, 80 and over, Retrospective Studies, Tomography, X-Ray Computed methods, Risk Assessment methods, Aortic Valve surgery, Treatment Outcome, Risk Factors, Transcatheter Aortic Valve Replacement methods, Deep Learning, Aortic Valve Stenosis diagnostic imaging, Aortic Valve Stenosis surgery
- Abstract
Purpose: To investigate survival prediction in patients undergoing transcatheter aortic valve replacement (TAVR) using deep learning (DL) methods applied directly to pre-interventional CT images and to compare performance with survival models based on scalar markers of body composition., Method: This retrospective single-center study included 760 patients undergoing TAVR (mean age 81 ± 6 years; 389 female). As a baseline, a Cox proportional hazards model (CPHM) was trained to predict survival on sex, age, and the CT body composition markers fatty muscle fraction (FMF), skeletal muscle radiodensity (SMRD), and skeletal muscle area (SMA) derived from paraspinal muscle segmentation of a single slice at L3/L4 level. The convolutional neural network (CNN) encoder of the DL model for survival prediction was pre-trained in an autoencoder setting with and without a focus on paraspinal muscles. Finally, a combination of DL and CPHM was evaluated. Performance was assessed by C-index and area under the receiver operating curve (AUC) for 1-year and 2-year survival. All methods were trained with five-fold cross-validation and were evaluated on 152 hold-out test cases., Results: The CNN for direct image-based survival prediction, pre-trained in a focussed autoencoder scenario, outperformed the baseline CPHM (CPHM: C-index = 0.608, 1Y-AUC = 0.606, 2Y-AUC = 0.594 vs. DL: C-index = 0.645, 1Y-AUC = 0.687, 2Y-AUC = 0.692). Combining DL and CPHM led to further improvement (C-index = 0.668, 1Y-AUC = 0.713, 2Y-AUC = 0.696)., Conclusions: Direct DL-based survival prediction shows potential to improve image feature extraction compared to segmentation-based scalar markers of body composition for risk assessment in TAVR patients., Competing Interests: Declaration of Competing Interest The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: S.N. was funded over a part of the study duration by RACOON (NUM), which is supported by the Federal Ministry of Education and Research of Germany under BMBF grant number 01KX2121. M.T. was funded over a part of the study duration by a grant from the BONFOR research program of the University of Bonn (application number 2020-2A-04). The funders had no influence on the conception and design of the study, the data analysis, the data collection, the preparation of the manuscript, and the decision to publish., (Copyright © 2023 Elsevier B.V. All rights reserved.)
- Published
- 2023
- Full Text
- View/download PDF
32. Cardiovascular magnetic resonance (CMR) and positron emission tomography (PET) imaging in the diagnosis and follow-up of patients with acute myocarditis and chronic inflammatory cardiomyopathy : A review paper with practical recommendations on behalf of the European Society of Cardiovascular Radiology (ESCR).
- Author
-
Caobelli F, Cabrero JB, Galea N, Haaf P, Loewe C, Luetkens JA, Muscogiuri G, and Francone M
- Subjects
- Humans, Follow-Up Studies, Tomography, X-Ray Computed methods, Predictive Value of Tests, Magnetic Resonance Imaging, Positron-Emission Tomography methods, Magnetic Resonance Spectroscopy, Myocarditis diagnostic imaging, Radiology, Cardiomyopathies diagnostic imaging
- Abstract
Advanced cardiac imaging techniques such as cardiovascular magnetic resonance (CMR) and positron emission tomography (PET) are widely used in clinical practice in patients with acute myocarditis and chronic inflammatory cardiomyopathies (I-CMP). We aimed to provide a review article with practical recommendations from the European Society of Cardiovascular Radiology (ESCR), in order to guide physicians in the use and interpretation of CMR and PET in clinical practice both for acute myocarditis and follow-up in chronic forms of I-CMP., (© 2023. The Author(s).)
- Published
- 2023
- Full Text
- View/download PDF
33. Post-interventional infectious complications in percutaneous transabdominal lymphatic interventions: an observational study.
- Author
-
Pieper CC, Geiger S, Kupczyk P, Luetkens JA, Köster T, Attenberger UI, and Schild HH
- Subjects
- Humans, Male, Female, Middle Aged, Retrospective Studies, Inflammation complications, Anti-Bacterial Agents therapeutic use, Chylothorax etiology, Chylous Ascites etiology, Cystitis, Pneumonia complications
- Abstract
The purpose of this retrospective study was to evaluate the occurrence of infectious complications and inflammatory reactions after transabdominal lymphatic-interventions. 63 lymphatic-interventions were performed in 60 patients (male/female: 35/25; mean age 56 [9-85] years) [chylothorax n = 48, chylous ascites n = 7, combined chylothorax/chylous ascites n = 5]. Post-interventional clinical course and laboratory findings were analyzed in the whole cohort as well as subgroups without (group A; n = 35) and with peri-interventional antibiotics (group B; n = 25) (pneumonia n = 16, drainage-catheter inflammation n = 5, colitis n = 1, cystitis n = 1, transcolonic-access n = 2). No septic complications associated with the intervention occurred. Leucocytes increased significantly, peaking on post-interventional day-1 (8.6 ± 3.9 × 10
6 cells/mL vs. 9.8 ± 4.7 × 106 cells/mL; p = 0.009) and decreased thereafter (day-10: 7.3 ± 2.7 × 106 cells/mL, p = 0.005). CRP-values were pathological in 89.5% of patients already at baseline (40.1 ± 63.9 mg/L) and increased significant on day-3 (77.0 ± 78.8 mg/L, p < 0.001). Values decreased thereafter (day-15: 25.3 ± 34.4 mg/L, p = 0.04). In subgroup B, 13/25 patients had febrile episodes post-interventionally (pneumonia n = 11, cystitis n = 1, drainage-catheter inflammation n = 1). One patient developed biliary peritonitis despite continued antibiotics and underwent cholecystectomy. Baseline leucocytes and CRP-levels were higher in group B than A, but with comparable post-interventional profiles. Clinically relevant infectious complications associated with transabdominal lymphatic-interventions are rare irrespective of peri-interventional antibiotic use. Post-interventional elevation of leucocytes and CRP are observed with normalization over 10-15 days., (© 2023. Springer Nature Limited.)- Published
- 2023
- Full Text
- View/download PDF
34. Long-Term Clinical Outcome of Abdomino-Thoracic Lymphatic Interventions of Traumatic and Non-Traumatic Lymphatic Leakage in Adults.
- Author
-
Kaminski LC, Wagenpfeil J, Buermann J, Lutz PL, Luetkens JA, Attenberger UI, Strassburg CP, Kalff JC, Schild HH, and Pieper CC
- Abstract
The aim of this study was to retrospectively evaluate the long-term results of lymphatic interventions in adults with abdomino-thoracic lymphatic pathologies. Management of abdomino-thoracic chylous effusions in adults undergoing X-ray-lymphangiography with or without lymph-vessel embolization (LVE) from 2010-2018 was reviewed. Patients underwent lymphangiography alone when imaging showed normal findings or lymphatic obstruction without leakage or reflux; otherwise, LVE was performed (leakage, reflux, obstruction with leakage or reflux, lymphatic masses). Technical and clinical success, complications, and long-term outcomes were assessed. 78 patients (47 male, median age 56.3 years) were treated for chylous effusions (60.3% traumatic, 39.7% non-traumatic). Lymphangiography showed leakage (48.7%), reflux (14.1%), obstruction (28.2%), lymphatic masses (5.1%), and normal findings (3.8%). Embolization was performed in 49/78 (62.8%) cases. Overall, treatment was clinically successful in 74.4% (mean follow-up of 28 months), with significant differences between LVE and lymphangiography (91.8% vs. 44.8%; p < 0.001), traumatic and non-traumatic etiologies (89.4% vs. 51.6%; p < 0.001), and leakage locations ( p = 0.003). The clinical success of LVE did not differ between leakage etiologies or locations. Complications occurred in 5 patients (2/5 needed treatment). Patients survived significantly longer after successful treatment (2679 vs. 927 days; p = 0.044) and without malignancy (3214 vs. 1550 days; p = 0.043). Lymphatic interventions are safe and effective. LVE should be attempted whenever feasible, as success is high (>90%). Successful intervention has a positive effect on patient survival.
- Published
- 2023
- Full Text
- View/download PDF
35. Deep Learning Super-Resolution Reconstruction for Fast and Motion-Robust T2-weighted Prostate MRI.
- Author
-
Bischoff LM, Peeters JM, Weinhold L, Krausewitz P, Ellinger J, Katemann C, Isaak A, Weber OM, Kuetting D, Attenberger U, Pieper CC, Sprinkart AM, and Luetkens JA
- Subjects
- Humans, Male, Aged, Magnetic Resonance Imaging, Prospective Studies, Prostate diagnostic imaging, Deep Learning, Prostatic Neoplasms diagnostic imaging, Prostatic Neoplasms surgery
- Abstract
Background Deep learning (DL) reconstructions can enhance image quality while decreasing MRI acquisition time. However, DL reconstruction methods combined with compressed sensing for prostate MRI have not been well studied. Purpose To use an industry-developed DL algorithm to reconstruct low-resolution T2-weighted turbo spin-echo (TSE) prostate MRI scans and compare these with standard sequences. Materials and Methods In this prospective study, participants with suspected prostate cancer underwent prostate MRI with a Cartesian standard-resolution T2-weighted TSE sequence (T2
C ) and non-Cartesian standard-resolution T2-weighted TSE sequence (T2NC ) between August and November 2022. Additionally, a low-resolution Cartesian DL-reconstructed T2-weighted TSE sequence (T2DL ) with compressed sensing DL denoising and resolution upscaling reconstruction was acquired. Image sharpness was assessed qualitatively by two readers using a five-point Likert scale (from 1 = nondiagnostic to 5 = excellent) and quantitatively by calculating edge rise distance. The Friedman test and one-way analysis of variance with post hoc Bonferroni and Tukey tests, respectively, were used for group comparisons. Prostate Imaging Reporting and Data System (PI-RADS) score agreement between sequences was compared by using Cohen κ. Results This study included 109 male participants (mean age, 68 years ± 8 [SD]). Acquisition time of T2DL was 36% and 29% lower compared with that of T2C and T2NC (mean duration, 164 seconds ± 20 vs 257 seconds ± 32 and 230 seconds ± 28; P < .001 for both). T2DL showed improved image sharpness compared with standard sequences using both qualitative (median score, 5 [IQR, 4-5] vs 4 [IQR, 3-4] for T2C and 4 [IQR, 3-4] for T2NC ; P < .001 for both) and quantitative (mean edge rise distance, 0.75 mm ± 0.39 vs 1.15 mm ± 0.68 for T2C and 0.98 mm ± 0.65 for T2NC ; P < .001 and P = .01) methods. PI-RADS score agreement between T2NC and T2DL was excellent (κ range, 0.92-0.94 [95% CI: 0.87, 0.98]). Conclusion DL reconstruction of low-resolution T2-weighted TSE sequences enabled accelerated acquisition times and improved image quality compared with standard acquisitions while showing excellent agreement with conventional sequences for PI-RADS ratings. Clinical trial registration no. NCT05820113 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Turkbey in this issue.- Published
- 2023
- Full Text
- View/download PDF
36. A novel and simple cardiac magnetic resonance score (PE 2 RT) predicts outcome in takotsubo syndrome.
- Author
-
Isaak A, Bratz J, Kravchenko D, Mesropyan N, Eckardt I, Bischoff LM, Weinhold L, Kuetting D, Pieper CC, Attenberger U, Zimmer S, and Luetkens JA
- Subjects
- Humans, Female, Middle Aged, Aged, Aged, 80 and over, Ventricular Function, Left, Retrospective Studies, Magnetic Resonance Imaging adverse effects, Prognosis, Magnetic Resonance Spectroscopy, Magnetic Resonance Imaging, Cine adverse effects, Predictive Value of Tests, Risk Factors, Takotsubo Cardiomyopathy diagnostic imaging, Heart Failure diagnostic imaging, Heart Failure etiology, Thrombosis
- Abstract
Objectives: To find simple imaging-based features on cardiac magnetic resonance (CMR) that are associated with major adverse cardiovascular events (MACE) in takotsubo syndrome (TTS)., Methods: Patients with TTS referred for CMR between 2007 and 2021 were retrospectively evaluated. Besides standard CMR analysis, commonly known complications of TTS based on expert knowledge were assessed and summarised via a newly developed PE
2 RT score (one point each for pleural effusion, pericardial effusion, right ventricular involvement, and ventricular thrombus). Clinical follow-up data was reviewed up to three years after discharge. The relationship between PE2 RT features and the occurrence of MACE (cardiovascular death or new hospitalisation due to acute myocardial injury, arrhythmia, or chronic heart failure) was examined using Cox regression analysis and Kaplan-Meier estimator., Results: Seventy-nine patients (mean age, 68 ± 14 years; 72 women) with TTS were included. CMR was performed in a median of 4 days (IQR, 2-6) after symptom onset. Over a median follow-up of 13.3 months (IQR, 0.4-36.0), MACE occurred in 14/79 (18%) patients: re-hospitalisation due to acute symptoms (9/79, 11%) or chronic heart failure symptoms (4/79, 5%), and cardiac death (1/79, 1%). Patients with MACE had a higher PE2 RT score (median [IQR], 2 [2-3] vs 1 [0-1]; p < 0.001). PE2 RT score was associated with MACE on Cox regression analysis (hazard ratio per PE2 RT feature, 2.44; 95%CI: 1.62-3.68; p < 0.001). Two or more PE2 RT complications were strongly associated with the occurrence of MACE (log-rank p < 0.001)., Conclusions: The introduced PE2 RT complication score might enable an easy-to-assess outcome evaluation of TTS patients by CMR., Key Points: • Complications like pericardial effusion, pleural effusion, right ventricular involvement, and ventricular thrombus (summarised as PE2 RT features) are relatively common in takotsubo syndrome. • The proposed PE2 RT score (one point per complication) was associated with the occurrence of major adverse cardiac events on follow-up. • Complications easily detected by cardiac magnetic resonance imaging can help clinicians derive long-term prognostic information on patients with takotsubo syndrome., (© 2023. The Author(s).)- Published
- 2023
- Full Text
- View/download PDF
37. Association between single-slice and whole heart measurements of epicardial and pericardial fat in cardiac MRI.
- Author
-
Vach M, Luetkens JA, Faron A, Isaak A, Salam B, Thomas D, Attenberger UI, and Sprinkart AM
- Subjects
- Humans, Retrospective Studies, Thorax, Adipose Tissue diagnostic imaging, Adipose Tissue pathology, Pericardium diagnostic imaging, Pericardium pathology, Magnetic Resonance Imaging
- Abstract
Background: Epicardial (ECF) and pericardial fat (PCF) are important prognostic markers for various cardiac diseases. However, volumetry of the fat compartments is time-consuming., Purpose: To investigate whether total volume of ECF and PCF can be estimated by axial single-slice measurements and in a four-chamber view., Material and Methods: A total of 113 individuals (79 patients and 34 healthy) were included in this retrospective magnetic resonance imaging (MRI) study. The total volume of ECF and PCF was determined using a 3D-Dixon sequence. Additionally, the area of ECF and PCF was obtained in single axial layers at five anatomical landmarks (left coronary artery, right coronary artery, right pulmonary artery, mitral valve, coronary sinus) of the Dixon sequence and in a four-chamber view of a standard cine sequence. Pearson's correlation coefficient was calculated between the total volume and each single-slice measurement., Results: Axial single-slice measurements of ECF and PCF correlated strongly with the total fat volumes at all landmarks (ECF: r = 0.85-0.94, P < 0.001; PCF: r = 0.89-0.94, P < 0.001). The best correlation was found at the level of the left coronary artery for ECF and PCF ( r = 0.94, P < 0.001). Correlation between single-slice measurement in the four-chamber view and the total ECF and PCF volume was lower ( r = 0.75 and r = 0.8, respectively, P < 0.001)., Conclusion: Single-slice measurements allow an estimation of ECF and PCF volume. This time-efficient analysis allows studies of larger patient cohorts and the opportunistic determination of ECF/PCF from routine examinations.
- Published
- 2023
- Full Text
- View/download PDF
38. Cardiac MRI Findings in Patients Clinically Referred for Evaluation of Post-Acute Sequelae of SARS-CoV-2 Infection.
- Author
-
Halfmann MC, Luetkens JA, Langenbach IL, Kravchenko D, Wenzel P, Emrich T, and Isaak A
- Abstract
Persistent or recurrent cardiovascular symptoms have been identified as one of the hallmarks of long-COVID or post-acute sequelae of SARS-CoV-2 infection (PASC). The purpose of this study was to determine the prevalence and extent of cardiac abnormalities in patients referred for cardiac MRI due to clinical evidence of PASC. To investigate this, two tertiary care hospitals identified all patients who were referred for cardiac MRI under the suspicion of PASC in a 2-year period and retrospectively included them in this study. Patients with previously known cardiac diseases were excluded. This resulted in a total cohort of 129 patients (63, 51% female; age 41 ± 16 years). The majority of patients (57%) showed normal cardiac results. No patient had active myocarditis or an acute myocardial infarction. However, 30% of patients had evidence of non-ischemic myocardial fibrosis, which exceeds the prevalence in the normal adult population and suggests that a possible history of myocarditis might explain persistent symptoms in the PASC setting.
- Published
- 2023
- Full Text
- View/download PDF
39. Cardiac involvement in non-cirrhotic portal hypertension: MRI detects myocardial fibrosis and oedema similar to compensated cirrhosis.
- Author
-
Isaak A, Chang J, Mesropyan N, Kravchenko D, Endler C, Bischoff L, Böhling N, Pieper CC, Kuetting D, Strassburg CP, Attenberger U, Jansen C, Praktiknjo M, and Luetkens JA
- Subjects
- Child, Humans, Female, Contrast Media, Prospective Studies, Gadolinium, Fibrosis, Magnetic Resonance Imaging methods, Myocardium pathology, Edema diagnostic imaging, Edema etiology, Edema pathology, Magnetic Resonance Imaging, Cine, Predictive Value of Tests, Cardiomyopathies diagnostic imaging, Cardiomyopathies etiology, Hypertension, Portal diagnostic imaging, Hypertension, Portal etiology, Hypertension, Portal pathology
- Abstract
Aims: The exact role of portal hypertension in cirrhotic cardiomyopathy remains unclear, and it is uncertain whether cardiac abnormalities also occur in non-cirrhotic portal hypertension (NCPH). This magnetic resonance imaging (MRI) study aimed to evaluate the presence of subclinical myocardial dysfunction, oedema, and fibrosis in NCPH., Methods and Results: In this prospective study (2018-2022), participants underwent multiparametric abdominal and cardiac MRI including assessment of cardiac function, myocardial oedema, late gadolinium enhancement (LGE), and abdominal and cardiac mapping [T1 and T2 relaxation times, extracellular volume fraction (ECV)]. A total of 111 participants were included [44 participants with NCPH (48 ± 15 years; 23 women), 47 cirrhotic controls, and 20 healthy controls]. The cirrhotic group was dichotomized (Child A vs. Child B/C). NCPH participants demonstrated a more hyperdynamic circulation compared with healthy controls (cardiac index: 3.7 ± 0.6 vs. 3.2 ± 0.8 L/min/m², P = 0.004; global longitudinal strain: -27.3 ± 4.6 vs. -24.6 ± 3.5%, P = 0.022). The extent of abnormalities indicating myocardial fibrosis and oedema in NCPH was comparable with Child A cirrhosis (e.g. LGE presence: 32 vs. 33 vs. 69%, P = 0.004; combined T1 and T2 elevations: 46 vs. 27 vs. 69%, P = 0.017; NCPH vs. Child A vs. Child B/C). Correlations between splenic T1 and myocardial T1 values were found (r = 0.41; P = 0.007). Splenic T1 values were associated with the presence of LGE (odds ratio, 1.010; 95% CI: 1.002, 1.019; P = 0.013)., Conclusion: MRI parameters of myocardial fibrosis and oedema were altered in participants with NCPH to a similar extent as in compensated cirrhosis and were associated with splenic markers of portal hypertension, indicating specific portal hypertensive cardiomyopathy., Competing Interests: Conflict of interest: None declared., (© The Author(s) 2022. Published by Oxford University Press on behalf of the European Society of Cardiology. All rights reserved. For permissions, please email: journals.permissions@oup.com.)
- Published
- 2023
- Full Text
- View/download PDF
40. Combining iterative metal artifact reduction and virtual monoenergetic images severely reduces hip prosthesis-associated artifacts in photon-counting detector CT.
- Author
-
Layer YC, Mesropyan N, Kupczyk PA, Luetkens JA, Isaak A, Dell T, Attenberger UI, and Kuetting D
- Subjects
- Retrospective Studies, Metals, Tomography, X-Ray Computed methods, Artifacts, Algorithms, Hip Prosthesis, Arthroplasty, Replacement, Hip
- Abstract
Aim of this study was to assess the impact of virtual monoenergetic images (VMI) in combination and comparison with iterative metal artifact reduction (IMAR) on hip prosthesis-associated artifacts in photon-counting detector CT (PCD-CT). Retrospectively, 33 scans with hip prosthesis-associated artifacts acquired during clinical routine on a PCD-CT between 08/2022 and 09/2022 were analyzed. VMI were reconstructed for 100-190 keV with and without IMAR, and compared to polychromatic images. Qualitatively, artifact extent and assessment of adjacent soft tissue were rated by two radiologists using 5-point Likert items. Quantitative assessment was performed measuring attenuation and standard deviation in most pronounced hypodense and hyperdense artifacts, artifact-impaired bone, muscle, vessels, bladder and artifact-free corresponding tissue. To quantify artifacts, an adjusted attenuation was calculated as the difference between artifact-impaired tissue and corresponding tissue without artifacts. Qualitative assessment improved for all investigated image reconstructions compared to polychromatic images (PI). VMI
100keV in combination with IMAR achieved best results (e.g. diagnostic quality of the bladder: median PI: 1.5 (range 1-4); VMI100keV+IMAR : 5 (3-5); p < 0.0001). In quantitative assessment VMI100keV with IMAR provided best artifact reduction with an adjusted attenuation closest to 0 (e.g. bone: PI: 302.78; VMI100keV+IMAR : 51.18; p < 0.0001). The combination of VMI and IMAR significantly reduces hip prosthesis-associated artifacts in PCD-CT and improves the diagnostic quality of surrounding tissue., (© 2023. The Author(s).)- Published
- 2023
- Full Text
- View/download PDF
41. Free-breathing pseudo-golden-angle bSSFP cine cardiac MRI for biventricular functional assessment in congenital heart disease.
- Author
-
Kravchenko D, Isaak A, Zhang S, Katemann C, Mesropyan N, Bischoff LM, Pieper CC, Kuetting D, Attenberger U, Weber O, Hart C, and Luetkens JA
- Subjects
- Humans, Prospective Studies, Magnetic Resonance Imaging methods, Magnetic Resonance Imaging, Cine methods, Breath Holding, Reproducibility of Results, Respiration, Heart Defects, Congenital diagnostic imaging
- Abstract
Purpose: To compare standard breath-hold (BH) cine imaging to a radial pseudo-golden-angle free-breathing (FB) technique in congenital heart disease (CHD)., Methods: In this prospective study, short-axis and 4-chamber BH and FB cardiac MRI sequences of 25 participants with CHD acquired at 1.5 Tesla, were quantitatively compared regarding ventricular volumes, function, interventricular septum thickness (IVSD), apparent signal to noise ratio (aSNR), and estimated contrast to noise ratio (eCNR). For qualitative comparison, three image quality criteria (contrast, endocardial edge definition, and artefacts) were rated on a 5-point Likert scale (5: excellent, 1: non-diagnostic). Paired t-Test was used for group comparisons, Bland-Altman analysis for agreement between techniques. Inter-reader agreement was compared using intraclass correlation coefficient., Results: IVSD (BH 7.4 ± 2.1 mm vs FB 7.4 ± 1.9 mm, p =.71), biventricular ejection fraction (left ventricle [LV]: 56.4 ± 10.8% vs 56.1 ± 9.3%, p =.83; right ventricle [RV]: 49.5 ± 8.6% vs 49.7 ± 10.1%, p =.83), and biventricular end diastolic volume (LV: 176.3 ± 63.9 ml vs 173.9 ± 64.9 ml, p =.90; RV: 185.4 ± 63.8 ml vs 189.6 ± 66.6 ml, p =.34) were comparable. Mean measurement time for FB short-axis sequences was 8.1 ± 1.3 compared to 4.4 ± 1.3 min for BH (p <.001). Subjective image quality between sequences was deemed comparable, (4.6 ± 0.6 vs 4.5 ± 0.6, p =.26, for 4-chamber views) with a significant difference regarding short-axis views (4.9 ± 0.3 vs 4.5 ± 0.6, p =.008). aSNR was similar (BH 25.8 ± 11.2 vs FB 22.2 ± 9.5, p =.24), while eCNR was higher for BH (89.1 ± 36.1 vs 68.5 ± 32.1, p =.03)., Conclusion: FB sequences yielded comparable results to BH regarding image quality, biventricular volumetry, and function, though measurement times were longer. The FB sequence described might be clinically valuable when BHs are insufficiently performed., Competing Interests: Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper., (Copyright © 2023 Elsevier B.V. All rights reserved.)
- Published
- 2023
- Full Text
- View/download PDF
42. Fetal Cardiac MRI of Complex Interrupted Aortic Arch.
- Author
-
Vollbrecht TM, Hart C, and Luetkens JA
- Subjects
- Humans, Fetus, Magnetic Resonance Imaging, Radiography, Aorta, Thoracic diagnostic imaging, Thoracic Surgical Procedures
- Published
- 2023
- Full Text
- View/download PDF
43. Cardiovascular Magnetic Resonance in Survivors of Critical Illness: Cardiac Abnormalities Are Associated With Acute Kidney Injury.
- Author
-
Isaak A, Pomareda I, Mesropyan N, Kravchenko D, Endler C, Bischoff L, Pieper CC, Kuetting D, Attenberger U, Zimmer S, Putensen C, Schewe JC, Kreyer S, and Luetkens JA
- Subjects
- Male, Humans, Adult, Contrast Media, Critical Illness, Gadolinium, Magnetic Resonance Imaging, Cine, Fibrosis, Magnetic Resonance Spectroscopy, Survivors, Cardiomyopathies diagnostic imaging, Cardiomyopathies etiology, Cardiomyopathies pathology, Heart Defects, Congenital, Acute Kidney Injury diagnosis, Acute Kidney Injury etiology
- Abstract
Background The objective of this study was to investigate cardiac abnormalities in intensive care unit (ICU) survivors of critical illness and to determine whether temporary acute kidney injury (AKI) is associated with more pronounced findings on cardiovascular magnetic resonance. Methods and Results There were 2175 patients treated in the ICU (from 2015 until 2021) due to critical illness who were screened for study eligibility. Post-ICU patients without known cardiac disease were prospectively recruited from March 2021 to May 2022. Participants underwent cardiovascular magnetic resonance including assessment of cardiac function, myocardial edema, late gadolinium enhancement, and mapping including extracellular volume fraction. Student t test, Mann-Whitney U test, and χ
2 tests were used. There were 48 ICU survivors (46±15 years of age, 28 men, 29 with AKI and continuous kidney replacement therapy, and 19 without AKI) and 20 healthy controls who were included. ICU survivors had elevated markers of myocardial fibrosis (T1: 995±31 ms versus 957±21 ms, P <0.001; extracellular volume fraction: 24.9±2.5% versus 22.8±1.2%, P <0.001; late gadolinium enhancement: 1% [0%-3%] versus 0% [0%-0%], P <0.001), more frequent focal late gadolinium enhancement lesions (21% versus 0%, P =0.03), and an impaired left ventricular function (eg, ejection fraction: 57±6% versus 60±5%, P =0.03; systolic longitudinal strain: 20.3±3.7% versus 23.1±3.5%, P =0.004) compared with healthy controls. ICU survivors with AKI had higher myocardial T1 (1002±33 ms versus 983±21 ms; P =0.046) and extracellular volume fraction values (25.6±2.6% versus 23.9±1.9%; P =0.02) compared with participants without AKI. Conclusions ICU survivors of critical illness without previously diagnosed cardiac disease had distinct abnormalities on cardiovascular magnetic resonance including signs of myocardial fibrosis and systolic dysfunction. Findings were more abnormal in participants who experienced AKI with necessity of continuous kidney replacement therapy during their ICU stay. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT05034588.- Published
- 2023
- Full Text
- View/download PDF
44. Percutaneous transhepatic biliary drainage: a retrospective single-center study of 372 patients.
- Author
-
Handke NA, Ollig A, Attenberger UI, Luetkens JA, Faron A, Pieper CC, Schmeel FC, Kupczyk PA, Meyer C, and Kuetting D
- Subjects
- Male, Humans, Female, Aged, Retrospective Studies, Drainage, Treatment Outcome, Bile Ducts, Cholestasis diagnostic imaging, Cholestasis surgery
- Abstract
Background: Complication rates in percutaneous transhepatic biliary drainage (PTBD) are non-uniform and vary considerably. In addition, the impact of peri-procedural risk factors is under-investigated., Purpose: To compare success and complication rates of PTBD in patients with and without accompanying technical risk factors., Material and Methods: A single-center retrospective study was conducted from January 2004 to December 2016. Patients receiving PTBD due to biliary obstruction or biliary leakage were included. Technical risk factors (non-distended bile ducts, ascites, obesity, anasarca, non-compliance) were assessed. Complications were classified according to the Society of Interventional Radiology., Results: In total, 372 patients were included (57.3% men, 42.7% women; mean age = 66 years). Overall, 466 PTBDs were performed. Of the patients, 70.1% presented with malignancy and biliary obstruction; 26.8% had benign biliary obstruction; 3.1% had biliary leakage. Technical risk factors were reported in 57 (15.3%) patients. Overall technical success of initial PTBD was 98.7%, primary technical success was 97.9%. In patients with non-dilatated bile ducts, primary technical success was 68.2%. Overall complication rate was 15.0% (8.1% major complications, 6.9% minor complications). Neither major nor minor complications were more frequent in patients with technical risk factors ( P > 0.05). In left-sided PTBD, hemorrhage was more frequent ( P = 0.015). Patients with malignancy were significantly more affected by drainage-related complications ( P = 0.004; odds ratio = 2.03). The mortality rate was 0.5% (n = 2)., Conclusion: PTBD is a safe and effective method for the treatment of biliary obstruction and biliary leaks. Complication rates are low, even in procedures with risk factors.
- Published
- 2023
- Full Text
- View/download PDF
45. T2 Turbo Spin Echo With Compressed Sensing and Propeller Acquisition (Sampling k-Space by Utilizing Rotating Blades) for Fast and Motion Robust Prostate MRI: Comparison With Conventional Acquisition.
- Author
-
Bischoff LM, Katemann C, Isaak A, Mesropyan N, Wichtmann B, Kravchenko D, Endler C, Kuetting D, Pieper CC, Ellinger J, Weber O, Attenberger U, and Luetkens JA
- Subjects
- Humans, Male, Middle Aged, Aged, Prostate diagnostic imaging, Reproducibility of Results, Signal-To-Noise Ratio, Artifacts, Magnetic Resonance Imaging methods, Prostatic Neoplasms diagnostic imaging
- Abstract
Objectives: The aim of this study was to compare a new compressed sensing (CS) method for T2-weighted propeller acquisitions (T2 CS ) with conventional T2-weighted propeller sequences (T2 conv ) in terms of achieving a higher image quality, while reducing the acquisition time., Materials and Methods: Male participants with a clinical suspicion of prostate cancer were prospectively enrolled and underwent prostate magnetic resonance imaging at 3 T. Axial and sagittal images of the T2 conv sequence and the T2 CS sequence were acquired. Sequences were qualitatively assessed by 2 blinded radiologists concerning artifacts, image-sharpness, lesion conspicuity, capsule delineation, and overall image quality using 5-point Likert items ranging from 1 (nondiagnostic) to 5 (excellent). The apparent signal-to-noise ratio and apparent contrast-to-noise ratio were evaluated. PI-RADS scores were assessed for both sequences. Statistical analysis was performed by using Wilcoxon signed rank test and paired samples t test. Intrarater and interrater reliability of qualitative image evaluation was assessed using intraclass correlation coefficient (ICC) estimates., Results: A total of 29 male participants were included (mean age, 66 ± 8 years). The acquisition time of the T2 CS sequence was respectively 26% (axial plane) and 24% (sagittal plane) shorter compared with the T2 conv sequence (eg, axial: 171 vs 232 seconds; P < 0.001). In the axial plane, the T2 CS sequence had fewer artifacts (4 [4-4.5] vs 4 [3-4]; P < 0.001), better image-sharpness (4 [4-4.5] vs 3 [3-3.5]; P < 0.001), better capsule delineation (4 [3-4] vs 3 [3-3.5]; P < 0.001), and better overall image quality (4 [4-4] vs 4 [3-4]; P < 0.001) compared with the T2 conv sequence. The ratings of lesion conspicuity were similar (4 [4-4] vs 4 [3-4]; P = 0.166). In the sagittal plane, the T2 CS sequence outperformed the T2 conv sequence in the categories artifacts (4 [4-4] vs 3 [3-4]; P < 0.001), image sharpness (4 [4-5] vs 4 [3-4]; P < 0.001), lesion conspicuity (4 [4-4] vs 4 [3-4]; P = 0.002), and overall image quality (4 [4-4] vs 4 [3-4]; P = 0.002). Capsule delineation was similar between both sequences (3 [3-4] vs 3 [3-3]; P = 0.07). Intraobserver and interobserver reliability for qualitative scoring were good (ICC intra: 0.92; ICC inter: 0.86). Quantitative analysis revealed a higher apparent signal-to-noise ratio (eg, axial: 52.2 ± 9.7 vs 22.8 ± 3.6; P < 0.001) and a higher apparent contrast-to-noise ratio (eg, axial: 44.0 ± 9.6 vs 18.6 ± 3.7; P ≤ 0.001) of the T2 CS sequence. PI-RADS scores were the same for both sequences in all participants., Conclusions: CS-accelerated T2-weighted propeller acquisition had a superior image quality compared with conventional T2-weighted propeller sequences while significantly reducing the acquisition time., Competing Interests: Conflicts of interest and sources of funding: J.A.L. received payments for lectures from Philips Healthcare and for activities related to the scientific advisory board for Bayer HealthCare. For the remaining authors none were declared., (Copyright © 2022 Wolters Kluwer Health, Inc. All rights reserved.)
- Published
- 2023
- Full Text
- View/download PDF
46. Computed tomography derived cervical fat-free muscle fraction as an imaging-based outcome marker in patients with acute ischemic stroke: a pilot study.
- Author
-
Mesropyan N, Khorsandian L, Faron A, Sprinkart AM, Dorn F, Paech D, Isaak A, Kuetting D, Pieper CC, Radbruch A, Attenberger UI, Reimann J, Bode FJ, Kornblum C, and Luetkens JA
- Subjects
- Humans, Female, Middle Aged, Aged, Aged, 80 and over, Pilot Projects, Retrospective Studies, Tomography, X-Ray Computed, Muscles, Ischemic Stroke, Stroke diagnostic imaging
- Abstract
Background: Outcome assessment in stroke patients is essential for evidence-based stroke care planning. Computed tomography (CT) is the mainstay of diagnosis in acute stroke. This study aimed to investigate whether CT-derived cervical fat-free muscle fraction (FFMF) as a biomarker of muscle quality is associated with outcome parameters after acute ischemic stroke., Methods: In this retrospective study, 66 patients (mean age: 76 ± 13 years, 30 female) with acute ischemic stroke in the anterior circulation who underwent CT, including CT-angiography, and endovascular mechanical thrombectomy of the middle cerebral artery between August 2016 and January 2020 were identified. Based on densitometric thresholds, cervical paraspinal muscles covered on CT-angiography were separated into areas of fatty and lean muscle and FFMF was calculated. The study cohort was binarized based on median FFMF (cutoff value: < 71.6%) to compare clinical variables and outcome data between two groups. Unpaired t test and Mann-Whitney U test were used for statistical analysis., Results: National Institute of Health Stroke Scale (NIHSS) (12.2 ± 4.4 vs. 13.6 ± 4.5, P = 0.297) and modified Rankin scale (mRS) (4.3 ± 0.9 vs. 4.4 ± 0.9, P = 0.475) at admission, and pre-stroke mRS (1 ± 1.3 vs. 0.9 ± 1.4, P = 0.489) were similar between groups with high and low FFMF. NIHSS and mRS at discharge were significantly better in patients with high FFMF compared to patients with low FFMF (NIHSS: 4.5 ± 4.4 vs. 9.5 ± 6.7; P = 0.004 and mRS: 2.9 ± 2.1 vs.3.9 ± 1.8; P = 0.049). 90-day mRS was significantly better in patients with high FFMF compared to patients with low FFMF (3.3 ± 2.2 vs. 4.3 ± 1.9, P = 0.045)., Conclusion: Cervical FFMF obtained from routine clinical CT might be a new imaging-based muscle quality biomarker for outcome prediction in stroke patients., (© 2023. The Author(s).)
- Published
- 2023
- Full Text
- View/download PDF
47. Fetal Cardiac Cine MRI with Doppler US Gating in Complex Congenital Heart Disease.
- Author
-
Vollbrecht TM, Hart C, Zhang S, Katemann C, Isaak A, Pieper CC, Kuetting D, Faridi B, Strizek B, Attenberger U, Kipfmueller F, Herberg U, Geipel A, and Luetkens JA
- Abstract
Purpose: To apply Doppler US (DUS)-gated fetal cardiac cine MRI in clinical routine and investigate diagnostic performance in complex congenital heart disease (CHD) compared with that of fetal echocardiography., Materials and Methods: In this prospective study (May 2021 to March 2022), women with fetuses with CHD underwent fetal echocardiography and DUS-gated fetal cardiac MRI on the same day. For MRI, balanced steady-state free precession cine images were acquired in the axial and optional sagittal and/or coronal orientations. Overall image quality was assessed on a four-point Likert scale (from 1 = nondiagnostic to 4 = good image quality). The presence of abnormalities in 20 fetal cardiovascular features was independently assessed by using both modalities. The reference standard was postnatal examination results. Differences in sensitivities and specificities were determined by using a random-effects model., Results: The study included 23 participants (mean age, 32 years ± 5 [SD]; mean gestational age, 36 weeks ± 1). Fetal cardiac MRI was completed in all participants. The median overall image quality of DUS-gated cine images was 3 (IQR, 2.5-4). In 21 of 23 participants (91%), underlying CHD was correctly assessed by using fetal cardiac MRI. In one case, the correct diagnosis was made by using MRI only (situs inversus and congenitally corrected transposition of the great arteries). Sensitivities (91.8% [95% CI: 85.7, 95.1] vs 93.6% [95% CI: 88.8, 96.2]; P = .53) and specificities (99.9% [95% CI: 99.2, 100] vs 99.9% [95% CI: 99.5, 100]; P > .99) for the detection of abnormal cardiovascular features were comparable between MRI and echocardiography, respectively., Conclusion: Using DUS-gated fetal cine cardiac MRI resulted in performance comparable with that of using fetal echocardiography for diagnosing complex fetal CHD. Keywords: Pediatrics, MR-Fetal (Fetal MRI), Cardiac, Heart, Congenital, Fetal Imaging, Cardiac MRI, Prenatal, Congenital Heart DiseaseClinical trial registration no. NCT05066399 Supplemental material is available for this article. © RSNA, 2023See also the commentary by Biko and Fogel in this issue., Competing Interests: Disclosures of conflicts of interest: T.M.V. No relevant relationships. C.H. No relevant relationships. S.Z. Salary from Philips. C.K. Employee of Philips, the manufacturer of the MRI system used in this study. A.I. Grant to author’s university from BONFOR and DFG. C.C.P. Educational grant from Guerbet to author’s institution; advisory board consulting fees from Guerbet to author; payment for speakers bureaus from Guerbet and Julius Zorn to author; support from Guerbet and Julius Zorn for attending meetings and/or travel. D.K. No relevant relationships. B.F. No relevant relationships. B.S. No relevant relationships. U.A. Consulting fees from Bayer Healthcare; payment from Siemens Healthineers for speakers bureau; support from Siemens Healthineers for attending meetings and/or travel. F.K. No relevant relationships. U.H. Leadership or fiduciary role in German Society of Pediatric Cardiology. A.G. No relevant relationships. J.A.L. Received payments for lectures from Philips Healthcare and for activities related to the scientific advisory board for Bayer Healthcare., (© 2023 by the Radiological Society of North America, Inc.)
- Published
- 2023
- Full Text
- View/download PDF
48. Alveolar Echinococcosis in a Patient with Presumed Autoimmune Hepatitis and Primary Sclerosing Cholangitis: An Unexpected Finding after Liver Transplantation.
- Author
-
Fronhoffs F, Dold L, Parčina M, Schneidewind A, Willis M, Barth TFE, Weismüller TJ, Zhou T, Lutz P, Luetkens JA, Gerlach P, Manekeller S, Kalff JC, Vilz TO, Strassburg CP, and Kristiansen G
- Abstract
Primary sclerosing cholangitis is an important reason for liver transplantation. Hepatic alveolar echinococcosis (AE) is caused by Echinococcus multilocularis and presents characteristic calcified conglomerates detected by ultrasound or computed tomography scan of the liver. Symptoms of AE only occur after a long period of infection when cholestasis or cholangitis becomes apparent. Here, we report on a patient with presumed autoimmune hepatitis and primary sclerosing cholangitis. After liver transplantation, alveolar echinococcosis was diagnosed in the liver explant.
- Published
- 2023
- Full Text
- View/download PDF
49. Cardiac adverse reactions of COVID-19 vaccination: cardiac MRI findings.
- Author
-
Kravchenko D and Luetkens JA
- Subjects
- Male, Humans, Contrast Media, Pandemics, Gadolinium, Magnetic Resonance Imaging adverse effects, COVID-19 Vaccines adverse effects, COVID-19 prevention & control
- Abstract
Background: The rapid development of COVID-19 vaccines in the wake of the COVID-19 pandemic has led to an equally expediently deployed vaccination campaign with more than 12 billion vaccinations administered worldwide. Reports of vaccine-associated adverse reactions (VAARs) have ranged from headaches and pain at the injection site to potentially life-threatening events such as cerebral venous sinus thrombosis. The heart has also not been spared of VAARs, as vaccine-associated myocardial infarction and more commonly, albeit still rare, myocarditis and perimyocarditis have been reported in predominantly young male recipients., Methodological Innovations: Cardiac magnetic resonance imaging findings of vaccine-associated myocarditis such as prolonged T1 and T2 relaxation times, increased T2 signal intensity ratio, and subepicardial late gadolinium enhancement have been demonstrated to be similar to those in virus-induced myocarditis, enabling the use of the modified 2018 Lake Louise Criteria for diagnostic purposes to confirm vaccination-associated myocardial inflammation. Other reported cardiac findings such as cardiomyopathies and arrhythmias were confined to case reports. The incidence of myocardial infarction was not noted to be higher than in the overall population., Conclusion: The overall preliminary prognosis of vaccine- associated myocarditis seems to be good as suggested by initial reports, but long-term follow-up is needed to sufficiently assess possible sequelae and consequences., (© 2022. The Author(s), under exclusive licence to Springer Medizin Verlag GmbH, ein Teil von Springer Nature.)
- Published
- 2022
- Full Text
- View/download PDF
50. Non-contrast free-breathing 3D cardiovascular magnetic resonance angiography using REACT (relaxation-enhanced angiography without contrast) compared to contrast-enhanced steady-state magnetic resonance angiography in complex pediatric congenital heart disease at 3T.
- Author
-
Isaak A, Mesropyan N, Hart C, Zhang S, Kravchenko D, Endler C, Katemann C, Weber O, Pieper CC, Kuetting D, Attenberger U, Dabir D, and Luetkens JA
- Subjects
- Male, Humans, Child, Child, Preschool, Retrospective Studies, Reproducibility of Results, Contrast Media, Predictive Value of Tests, Magnetic Resonance Angiography methods, Heart Defects, Congenital diagnostic imaging
- Abstract
Background: To evaluate the great vessels in young children with complex congenital heart disease (CHD) using non-contrast cardiovascular magnetic resonance angiography (CMRA) based on three-dimensional relaxation-enhanced angiography without contrast (REACT) in comparison to contrast-enhanced steady-state CMRA., Methods: In this retrospective study from April to July 2021, respiratory- and electrocardiogram-gated native REACT CMRA was compared to contrast-enhanced single-phase steady-state CMRA in children with CHD who underwent CMRA at 3T under deep sedation. Vascular assessment included image quality (1 = non-diagnostic, 5 = excellent), vessel diameter, and diagnostic findings. For statistical analysis, paired t-test, Pearson correlation, Bland-Altman analysis, Wilcoxon test, and intraclass correlation coefficients (ICC) were applied., Results: Thirty-six young children with complex CHD (median 4 years, interquartile range, 2-5; 20 males) were included. Native REACT CMRA was obtained successfully in all patients (mean scan time: 4:22 ± 1:44 min). For all vessels assessed, diameters correlated strongly between both methods (Pearson r = 0.99; bias = 0.04 ± 0.61 mm) with high interobserver reproducibility (ICC: 0.99 for both CMRAs). Native REACT CMRA demonstrated comparable overall image quality to contrast-enhanced CMRA (3.9 ± 1.0 vs. 3.8 ± 0.9, P = 0.018). With REACT CMRA, better image quality was obtained at the ascending aorta (4.8 ± 0.5 vs. 4.3 ± 0.8, P < 0.001), coronary roots (e.g., left: 4.1 ± 1.0 vs. 3.3 ± 1.1, P = 0.001), and inferior vena cava (4.6 ± 0.5 vs. 3.2 ± 0.8, P < 0.001). In all patients, additional vascular findings were assessed equally with native REACT CMRA and the contrast-enhanced reference standard (n = 6)., Conclusion: In young children with complex CHD, REACT CMRA can provide gadolinium-free high image quality, accurate vascular measurements, and equivalent diagnostic quality compared to standard contrast-enhanced CMRA., (© 2022. The Author(s).)
- Published
- 2022
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.