1. Cut-offs for relapse detection in men with stage I testicular germ cell tumors during active surveillance within a prospective multicentre cohort study using either raw or housekeeper normalized miR-371a-3p serum levels.
- Author
-
Fankhauser CD, Wettstein MS, Christiansen AJ, Rothermundt C, Cathomas R, Kaufmann E, Sigg S, Templeton AJ, Hirschi-Blickenstorfer A, Lorch A, Gillessen S, Beyer J, and Hermanns T
- Subjects
- Humans, Male, Prospective Studies, Adult, Neoplasm Staging, Middle Aged, Young Adult, Biomarkers, Tumor blood, Biomarkers, Tumor genetics, Cohort Studies, Watchful Waiting, Testicular Neoplasms blood, Testicular Neoplasms genetics, Testicular Neoplasms diagnosis, Testicular Neoplasms pathology, Neoplasms, Germ Cell and Embryonal blood, Neoplasms, Germ Cell and Embryonal genetics, Neoplasms, Germ Cell and Embryonal diagnosis, MicroRNAs blood, Neoplasm Recurrence, Local blood, Neoplasm Recurrence, Local genetics, Neoplasm Recurrence, Local diagnosis
- Abstract
Purpose: MiR-371a-3p represents a novel liquid biomarker that detects all histologies of germ-cell tumors (GCT) except teratoma. However, it is currently unclear whether miR-371a-3p results obtained directly from RT-PCR (raw Cq) or normalized for housekeeper genes and transformed into the relative quantity (RQ) value should be used and at what cut-off level. The purpose of this research was to evaluate, which values should be used, and a potential cut-off level for relapse-detection to inform subsequent studies., Materials and Methods: We applied a CE-certified qRT-PCR test to measure miR-371a-3p at each follow-up visit during active surveillance in 34 men with stage I testicular GCT. MiR-371a-3p levels were calculated by the ΔΔ method., Results: About 18 Patients had pure seminoma and 16 had mixed or nonseminomatous testicular GCT. Recurrences were detected in 10 patients and were correctly identified by both raw and housekeeper-normalized miR-371a-3p serum levels. The raw Cq, with a cut-off value of <28, resulted in only 1 false positive (3%), whereas RQ, with a cut-off value of >15, produced 6 false positive results (17%). Most of these false positive results normalized in subsequent measurements. The RQ approach detected recurrence in 1 patient 6 months earlier than the raw Cq approach., Conclusion: Our preliminary data suggest that this CE-certified assay, using previously suggested cut-off values, is a promising method for detecting disease recurrence, provided a confirmatory second test is conducted to identify false positive results. To avoid unnecessary scans or overtreatment, we are currently validating this assay and cut-offs in a prospective cohort study., Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper., (Copyright © 2024 The Author(s). Published by Elsevier Inc. All rights reserved.)
- Published
- 2024
- Full Text
- View/download PDF