Heat losses in ATES systems: The impact of processes, storage geometry and temperature

Authors :
Beernink, Stijn
Hartog, Niels
Vardon, Philip J.
Bloemendal, Martin
Beernink, Stijn
Hartog, Niels
Vardon, Philip J.
Bloemendal, Martin
Source :
Geothermics vol.117 (2024) [ISSN 0375-6505]
Publication Year :
2024

Abstract

The technical and economic success of an Aquifer Thermal Energy Storage (ATES) system depends strongly on its thermal recovery efficiency, i.e. the ratio of the amount of energy that is recovered to the energy that was injected. Typically, conduction most strongly determines the thermal recovery efficiency of ATES systems at low storage temperatures (<25 °C), while the impact of buoyancy-driven flow can lead to high additional heat losses at high storage temperatures (>50 °C). To date, however, it is unclear how the relative contribution of these processes and mechanical dispersion to heat losses across a broad temperature range is affected by their interaction for the wide range of storage conditions that can be encountered in practice. Since such process-based insights are important to predict ATES performance and support the design phase, numerical thermo-hydraulic ATES simulations were conducted for a wide range of realistic operational storage conditions ([15–90 °C], [50,000–1,000,000 m3/year]) and hydrogeological conditions (aquifer thickness, horizontal hydraulic conductivity, anisotropy). The simulated heat loss fractions of all scenarios were evaluated with respect to analytical solutions to assess the contribution of the individual heat loss processes. Results show that the wide range of heat losses (10–80 % in the 5th year) is the result of varying contributions of conduction, dispersion and buoyancy-driven flow, which are largely determined by the geometry of the storage volume (ratio of screen length / thermal radius, L/Rth) and the potential for buoyancy-driven flow (q0) as affected by the storage temperature and hydraulic conductivity of the aquifer. For ATES systems where conduction dominates the heat losses, a L/Rth ratio of 2 minimizes the thermal area over volume ratio (A/V) and resulting heat losses for a given storage volume. In contrast however, the impact of dispersion decreases with L/R<sub

Details

Database :
OAIster
Journal :
Geothermics vol.117 (2024) [ISSN 0375-6505]
Notes :
DOI: 10.1016/j.geothermics.2023.102889, English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1445835392
Document Type :
Electronic Resource