Back to Search Start Over

Shifting from glucose diagnosis to the new HbA1c diagnosis would reduce the ability of the Finnish Diabetes Risk Score (FINDRISC)in screening glucose abnormalities within a real-life primary healthcare preventive strategy.

Authors :
Universitat Rovira i Virgili
Costa B; Barrio F; Piñol J; Cabré J; Mundet X; Sagarra R; Salas-Salvadó J; Solà-Morales O
Universitat Rovira i Virgili
Costa B; Barrio F; Piñol J; Cabré J; Mundet X; Sagarra R; Salas-Salvadó J; Solà-Morales O
Source :
Bmc Medicine; 10.1186/1741-7015-11-45; Bmc Medicine. 11 (1): 45-
Publication Year :
2013

Abstract

Background: To investigate differences in the performance of the Finnish Diabetes Risk Score (FINDRISC) as a screening tool for glucose abnormalities after shifting from glucose-based diagnostic criteria to the proposed new hemoglobin (Hb)A1c-based criteria.Methods: A cross-sectional primary-care study was conducted as the first part of an active real-life lifestyle intervention to prevent type 2 diabetes within a high-risk Spanish Mediterranean population. Individuals without diabetes aged 45-75 years (n = 3,120) were screened using the FINDRISC. Where feasible, a subsequent 2-hour oral glucose tolerance test and HbA1c test were also carried out (n = 1,712). The performance of the risk score was calculated by applying the area under the curve (AUC) for the receiver operating characteristic, using three sets of criteria (2-hour glucose, fasting glucose, HbA1c) and three diagnostic categories (normal, pre-diabetes, diabetes).Results: Defining diabetes by a single HbA1c measurement resulted in a significantly lower diabetes prevalence (3.6%) compared with diabetes defined by 2-hour plasma glucose (9.2%), but was not significantly lower than that obtained using fasting plasma glucose (3.1%). The FINDRISC at a cut-off of 14 had a reasonably high ability to predict diabetes using the diagnostic criteria of 2-hour or fasting glucose (AUC = 0.71) or all glucose abnormalities (AUC = 0.67 and 0.69, respectively). When HbA1c was used as the primary diagnostic criterion, the AUC for diabetes detection dropped to 0.67 (5.6% reduction in comparison with either 2-hour or fasting glucose) and fell to 0.55 for detection of all glucose abnormalities (17.9% and 20.3% reduction, respectively), with a relevant decrease in sensitivity of the risk score.Conclusions: A shift from glucose-base

Details

Database :
OAIster
Journal :
Bmc Medicine; 10.1186/1741-7015-11-45; Bmc Medicine. 11 (1): 45-
Publication Type :
Electronic Resource
Accession number :
edsoai.on1443596278
Document Type :
Electronic Resource