Single-loop control scheme for electrolytic capacitor-less AC–DC rectifiers with PFC in continuous conduction mode

Authors :
Universitat Rovira i Virgili
Nassary M; Orabi M; El Aroudi A
Universitat Rovira i Virgili
Nassary M; Orabi M; El Aroudi A
Source :
Electronics Letters; 10.1049/el.2020.0023; Electronics Letters. 56 (10): 506-508
Publication Year :
2020

Abstract

© The Institution of Engineering and Technology 2020. A new simplified control scheme is proposed for AC–DC electrolytic capacitor-less converters operating in continuous conduction mode (CCM). The proposed method has a single-loop controller responsible for both regulation and power factor correction (PFC). In comparison with the two-loop conventional CCM current mode controller, the proposed scheme does not need a multiplier or extra sensors hence simplifying the control circuitry and its design procedures. Modelling of the closed-loop converter is addressed and experimental results are provided to show the feasibility of the control scheme.