Back to Search Start Over

Characterising spinal cerebrospinal fluid flow in the pig with phase-contrast magnetic resonance imaging

Authors :
Bessen, Madeleine Amy; https://orcid.org/0000-0003-0369-6448
Gayen, Christine Diana; https://orcid.org/0000-0002-1877-275X
Quarrington, Ryan David; https://orcid.org/0000-0002-0633-2482
Walls, Angela Catherine; https://orcid.org/0000-0001-9489-2991
Leonard, Anna Victoria; https://orcid.org/0000-0002-9430-3314
Kurtcuoglu, Vartan; https://orcid.org/0000-0003-2665-0995
Jones, Claire Frances; https://orcid.org/0000-0002-0995-1182
Bessen, Madeleine Amy; https://orcid.org/0000-0003-0369-6448
Gayen, Christine Diana; https://orcid.org/0000-0002-1877-275X
Quarrington, Ryan David; https://orcid.org/0000-0002-0633-2482
Walls, Angela Catherine; https://orcid.org/0000-0001-9489-2991
Leonard, Anna Victoria; https://orcid.org/0000-0002-9430-3314
Kurtcuoglu, Vartan; https://orcid.org/0000-0003-2665-0995
Jones, Claire Frances; https://orcid.org/0000-0002-0995-1182
Source :
Bessen, Madeleine Amy; Gayen, Christine Diana; Quarrington, Ryan David; Walls, Angela Catherine; Leonard, Anna Victoria; Kurtcuoglu, Vartan; Jones, Claire Frances (2023). Characterising spinal cerebrospinal fluid flow in the pig with phase-contrast magnetic resonance imaging. Fluids and Barriers of the CNS, 20(1):5.
Publication Year :
2023

Abstract

Background: Detecting changes in pulsatile cerebrospinal fluid (CSF) flow may assist clinical management decisions, but spinal CSF flow is relatively understudied. Traumatic spinal cord injuries (SCI) often cause spinal cord swelling and subarachnoid space (SAS) obstruction, potentially causing pulsatile CSF flow changes. Pigs are emerging as a favoured large animal SCI model; therefore, the aim of this study was to characterise CSF flow along the healthy pig spine. Methods: Phase-contrast magnetic resonance images (PC-MRI), retrospectively cardiac gated, were acquired for fourteen laterally recumbent, anaesthetised and ventilated, female domestic pigs (22–29 kg). Axial images were obtained at C2/C3, T8/T9, T11/T12 and L1/L2. Dorsal and ventral SAS regions of interest (ROI) were manually segmented. CSF flow and velocity were determined throughout a cardiac cycle. Linear mixed-effects models, with post-hoc comparisons, were used to identify differences in peak systolic/diastolic flow, and maximum velocity (cranial/caudal), across spinal levels and dorsal/ventral SAS. Velocity wave speed from C2/C3 to L1/L2 was calculated. Results: PC-MRI data were obtained for 11/14 animals. Pulsatile CSF flow was observed at all spinal levels. Peak systolic flow was greater at C2/C3 (dorsal: − 0.32 ± 0.14 mL/s, ventral: − 0.15 ± 0.13 mL/s) than T8/T9 dorsally (− 0.04 ± 0.03 mL/s; p < 0.001), but not different ventrally (− 0.08 ± 0.08 mL/s; p = 0.275), and no difference between thoracolumbar levels (p > 0.05). Peak diastolic flow was greater at C2/C3 (0.29 ± 0.08 mL/s) compared to T8/T9 (0.03 ± 0.03 mL/s, p < 0.001) dorsally, but not different ventrally (p = 1.000). Cranial and caudal maximum velocity at C2/C3 were greater than thoracolumbar levels dorsally (p < 0.001), and T8/T9 and L1/L2 ventrally (p = 0.022). Diastolic velocity wave speed was 1.41 ± 0.39 m/s dorsally and 1.22 ± 0.21 m/s ventrally, and systolic velocity wave speed was 1.02 ± 0.25 m/s dorsally and 0.91 ± 0.22 m/s ve

Details

Database :
OAIster
Journal :
Bessen, Madeleine Amy; Gayen, Christine Diana; Quarrington, Ryan David; Walls, Angela Catherine; Leonard, Anna Victoria; Kurtcuoglu, Vartan; Jones, Claire Frances (2023). Characterising spinal cerebrospinal fluid flow in the pig with phase-contrast magnetic resonance imaging. Fluids and Barriers of the CNS, 20(1):5.
Notes :
application/pdf, info:doi/10.5167/uzh-256527, English, English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1443057907
Document Type :
Electronic Resource