Back to Search
Start Over
Taking a walk on the heart failure side:comparison of metabolic variables during walking and maximal exertion
- Source :
- Mapelli , M , Salvioni , E , Bonomi , A , Paneroni , M , Raimondo , R , Gugliandolo , P , Mattavelli , I , Bidoglio , J , Mirza , K K , La Rovere , M T , Gustafsson , F & Agostoni , P 2024 , ' Taking a walk on the heart failure side : comparison of metabolic variables during walking and maximal exertion ' , ESC heart failure , vol. 11 , no. 2 , pp. 1269-1274 .
- Publication Year :
- 2024
-
Abstract
- AIMS: Although cardiopulmonary exercise testing (CPET) is the gold standard to assess exercise capacity, simpler tests (i.e., 6-min walk test, 6MWT) are also commonly used. The aim of this study was to evaluate the relationship between cardiorespiratory parameters during CPET and 6MWT in a large, multicentre, heterogeneous population.METHODS: We included athletes, healthy subjects, and heart failure (HF) patients of different severity, including left ventricular assist device (LVAD) carriers, who underwent both CPET and 6MWT with oxygen consumption measurement.RESULTS: We enrolled 186 subjects (16 athletes, 40 healthy, 115 non-LVAD HF patients, and 15 LVAD carriers). CPET-peakV̇O 2 was 41.0 [35.0-45.8], 26.2 [23.1-31.0], 12.8 [11.1-15.3], and 15.2 [13.6-15.6] ml/Kg/min in athletes, healthy, HF patients, and LVAD carriers, respectively (P < 0.001). During 6MWT they used 63.5 [56.3-76.8], 72.0 [57.8-81.0], 95.5 [80.3-109], and 95.0 [92.0-99.0] % of their peakV̇O 2 , respectively. None of the athletes, 1 healthy (2.5%), 30 HF patients (26.1%), and 1 LVAD carrier (6.7%), reached a 6MWT-V̇O 2 higher than their CPET-peakV̇O 2 . Both 6MWT-V̇O 2 and walked distance were significantly associated with CPET-peakV̇O 2 in the whole population (R 2 = 0.637 and R 2 = 0.533, P ≤ 0.001) but not in the sub-groups. This was confirmed after adjustment for groups. CONCLUSIONS: The 6MWT can be a maximal effort especially in most severe HF patients and suggest that, in absence of prognostic studies related to 6MWT metabolic values, CPET should remain the first method of choice in the functional assessment of patients with HF as well as in sport medicine.
Details
- Database :
- OAIster
- Journal :
- Mapelli , M , Salvioni , E , Bonomi , A , Paneroni , M , Raimondo , R , Gugliandolo , P , Mattavelli , I , Bidoglio , J , Mirza , K K , La Rovere , M T , Gustafsson , F & Agostoni , P 2024 , ' Taking a walk on the heart failure side : comparison of metabolic variables during walking and maximal exertion ' , ESC heart failure , vol. 11 , no. 2 , pp. 1269-1274 .
- Notes :
- application/pdf, English
- Publication Type :
- Electronic Resource
- Accession number :
- edsoai.on1439553802
- Document Type :
- Electronic Resource