Back to Search Start Over

A sleep stage estimation algorithm based on cardiorespiratory signals derived from a suprasternal pressure sensor

Authors :
Cerina, Luca
Overeem, Sebastiaan
Papini, Gabriele B.
van Dijk, Johannes P
Vullings, Rik
van Meulen, Fokke
Ross, Marco
Cerny, Andreas
Anderer, Peter
Fonseca, Pedro
Cerina, Luca
Overeem, Sebastiaan
Papini, Gabriele B.
van Dijk, Johannes P
Vullings, Rik
van Meulen, Fokke
Ross, Marco
Cerny, Andreas
Anderer, Peter
Fonseca, Pedro
Source :
Journal of Sleep Research vol.33 (2024) nr.2 [ISSN 0962-1105]
Publication Year :
2024

Abstract

Automatic estimation of sleep structure is an important aspect in moving sleep monitoring from clinical laboratories to people's homes. However, the transition to more portable systems should not happen at the expense of important physiological signals, such as respiration. Here, we propose the use of cardiorespiratory signals obtained by a suprasternal pressure (SSP) sensor to estimate sleep stages. The sensor is already used for diagnosis of sleep-disordered breathing (SDB) conditions, but besides respiratory effort it can detect cardiac vibrations transmitted through the trachea. We collected the SSP sensor signal in 100 adults (57 male) undergoing clinical polysomnography for suspected sleep disorders, including sleep apnea syndrome, insomnia, and movement disorders. Here, we separate respiratory effort and cardiac activity related signals, then input these into a neural network trained to estimate sleep stages. Using the original mixed signal the results show a moderate agreement with manual scoring, with a Cohen's kappa of 0.53 in Wake/N1-N2/N3/rapid eye movement sleep discrimination and 0.62 in Wake/Sleep. We demonstrate that decoupling the two signals and using the cardiac signal to estimate the instantaneous heart rate improves the process considerably, reaching an agreement of 0.63 and 0.71. Our proposed method achieves high accuracy, specificity, and sensitivity across different sleep staging tasks. We also compare the total sleep time calculated with our method against manual scoring, with an average error of -1.83 min but a relatively large confidence interval of ±55 min. Compact systems that employ the SSP sensor information-rich signal may enable new ways of clinical assessments, such as night-to-night variability in obstructive sleep apnea and other sleep disorders.

Details

Database :
OAIster
Journal :
Journal of Sleep Research vol.33 (2024) nr.2 [ISSN 0962-1105]
Notes :
Cerina, Luca
Publication Type :
Electronic Resource
Accession number :
edsoai.on1427410518
Document Type :
Electronic Resource