Back to Search Start Over

Machine perfusion techniques for liver transplantation - A meta-analysis of the first seven randomized-controlled trials

Authors :
Parente, Alessandro
Tirotta, Fabio
Pini, Alessia
Eden, Janina
Dondossola, Daniele
Manzia, Tommaso M
Dutkowski, Philipp
Schlegel, Andrea
Pini, Alessia (ORCID:0000-0001-9235-3062)
Parente, Alessandro
Tirotta, Fabio
Pini, Alessia
Eden, Janina
Dondossola, Daniele
Manzia, Tommaso M
Dutkowski, Philipp
Schlegel, Andrea
Pini, Alessia (ORCID:0000-0001-9235-3062)
Publication Year :
2023

Abstract

Background & aims: Machine perfusion is increasingly being tested in clinical transplantation. Despite this, the number of large prospective clinical trials remains limited. The aim of this study was to compare the impact of machine perfusion vs. static cold storage (SCS) on outcomes after liver transplantation. Methods: A systematic search of MEDLINE, EMBASE, CINAHL and the Cochrane Central Register of Controlled Trials (CENTRAL) was conducted to identify randomized-controlled trials (RCTs) comparing "post-transplant" outcomes following machine perfusion vs. SCS. Data were pooled using random effect models. Risk ratios (RRs) were calculated for relevant outcomes. The quality of evidence was rated using the GRADE-framework. Results: Seven RCTs were identified (four on hypothermic oxygenated [HOPE] and three on normothermic machine perfusion [NMP]), including a total number of 1,017 patients. Both techniques were associated with significantly lower rates of early allograft dysfunction (NMP: n = 41/282, SCS: n = 74/253, RR 0.50, 95% CI 0.30-0.86, p = 0.01, I2 = 39%; HOPE: n = 45/241, SCS: n = 97/241, RR 0.48, 95% CI 0.35-0.65, p < 0.00001, I2 = 5%). The HOPE approach led to a significant reduction in major complications (Clavien Grade ≥IIIb; HOPE: n = 90/241; SCS: n = 117/241, RR 0.76, 95% CI 0.63-0.93, p = 0.006, I2 = 0%), "re-transplantation" (HOPE: n = 1/163; SCS: n = 11/163; RR 0.21, 95% CI 0.04-0.96, p = 0.04; I2 = 0%) and graft loss (HOPE: n = 7/163; SCS: n = 19/163; RR 0.40, 95% CI 0.17-0.95, p = 0.04; I2 = 0%). Both perfusion techniques were found to 'likely' reduce overall biliary complications and non-anastomotic strictures. Conclusions: Although this study provides the highest current evidence on the role of machine perfusion, outcomes remain limited to a 1-year follow-up after liver transplantation. Comparative RCTs and large

Details

Database :
OAIster
Notes :
English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1414463892
Document Type :
Electronic Resource