Back to Search Start Over

Dual-step prospective ECG-triggered 128-slice dual-source CT for evaluation of coronary arteries and cardiac function without heart rate control: a technical note

Authors :
Feuchtner, G
Götti, R
Plass, A
Baumueller, S
Stolzmann, P
Scheffel, H
Wieser, M
Marincek, B
Alkadhi, H
Leschka, S
Feuchtner, G
Götti, R
Plass, A
Baumueller, S
Stolzmann, P
Scheffel, H
Wieser, M
Marincek, B
Alkadhi, H
Leschka, S
Source :
Feuchtner, G; Götti, R; Plass, A; Baumueller, S; Stolzmann, P; Scheffel, H; Wieser, M; Marincek, B; Alkadhi, H; Leschka, S (2010). Dual-step prospective ECG-triggered 128-slice dual-source CT for evaluation of coronary arteries and cardiac function without heart rate control: a technical note. European Radiology, 20(9):2092-2099.
Publication Year :
2010

Abstract

PURPOSE: To describe prospective ECG-triggered dual-source CT dual-step pulsing (pECG(dual_step)) for evaluation of coronary arteries and cardiac function. METHODS: Fifty-one consecutive patients pre- or post-cardiovascular surgery were examined with adaptive sequential tube current modulated (pECG(dual-step)) 128-slice dual-source CT without heart rate control (main padding window: 40% RR interval >65 bpm/70% RR interval <65 bpm). Image quality of coronary arteries was graded (4-point scale), and cardiac function was evaluated. RESULTS: Mean HR was 68 bpm. Thirty-seven patients were in stable sinus rhythm (SR); 14 had arrhythmia. Image quality of coronary arteries was diagnostic in 804/816 (98%) of segments. The number of non-diagnostic segments was higher in patients with arrhythmia as compared to those in SR (4% vs. 0.5%; p = 0.01), and there were fewer segments with excellent image quality (79% vs. 94%; p < 0.001) and more segments with impaired image quality (p < 0.001 and p = 0.002). Global and regional LV function could be evaluated in 41 (80%) and 47 (92%) patients, and valvular function in 48 (94%). In 11/14 of patients with arrhythmia, the second step switched to full mAs, increasing radiation exposure to 8.6 mAs (p < 0.001). The average radiation dose was 3.8 mSv (range, 1.7-7.9) in patients in SR. CONCLUSION: pECG(dual-step)128-slice DSCT is feasible for the evaluation of coronary arteries and cardiac function without heart rate control in patients in stable sinus rhythm at a low radiation dose.

Details

Database :
OAIster
Journal :
Feuchtner, G; Götti, R; Plass, A; Baumueller, S; Stolzmann, P; Scheffel, H; Wieser, M; Marincek, B; Alkadhi, H; Leschka, S (2010). Dual-step prospective ECG-triggered 128-slice dual-source CT for evaluation of coronary arteries and cardiac function without heart rate control: a technical note. European Radiology, 20(9):2092-2099.
Notes :
application/pdf, info:doi/10.5167/uzh-33640, English, English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1400962474
Document Type :
Electronic Resource