Back to Search Start Over

CIRCA: comprehensible online system in support of chest X-rays-based COVID-19 diagnosis

Authors :
Prazuch, Wojciech
Suwalska, Aleksandra
Socha, Marek
Tobiasz, Joanna
Foszner, Pawel
Jaroszewicz, Jerzy
Gruszczynska, Katarzyna
Sliwinska, Magdalena
Walecki, Jerzy
Popiela, Tadeusz
Przybylski, Grzegorz
Cieszanowski, Andrzej
Nowak, Mateusz
Pawlowska, Malgorzata
Flisiak, Robert
Simon, Krzysztof
Zapolska, Gabriela
Gizycka, Barbara
Szurowska, Edyta
Group, POLCOVID Study
Marczyk, Michal
Polanska, Joanna
Prazuch, Wojciech
Suwalska, Aleksandra
Socha, Marek
Tobiasz, Joanna
Foszner, Pawel
Jaroszewicz, Jerzy
Gruszczynska, Katarzyna
Sliwinska, Magdalena
Walecki, Jerzy
Popiela, Tadeusz
Przybylski, Grzegorz
Cieszanowski, Andrzej
Nowak, Mateusz
Pawlowska, Malgorzata
Flisiak, Robert
Simon, Krzysztof
Zapolska, Gabriela
Gizycka, Barbara
Szurowska, Edyta
Group, POLCOVID Study
Marczyk, Michal
Polanska, Joanna
Publication Year :
2022

Abstract

Due to the large accumulation of patients requiring hospitalization, the COVID-19 pandemic disease caused a high overload of health systems, even in developed countries. Deep learning techniques based on medical imaging data can help in the faster detection of COVID-19 cases and monitoring of disease progression. Regardless of the numerous proposed solutions for lung X-rays, none of them is a product that can be used in the clinic. Five different datasets (POLCOVID, AIforCOVID, COVIDx, NIH, and artificially generated data) were used to construct a representative dataset of 23 799 CXRs for model training; 1 050 images were used as a hold-out test set, and 44 247 as independent test set (BIMCV database). A U-Net-based model was developed to identify a clinically relevant region of the CXR. Each image class (normal, pneumonia, and COVID-19) was divided into 3 subtypes using a 2D Gaussian mixture model. A decision tree was used to aggregate predictions from the InceptionV3 network based on processed CXRs and a dense neural network on radiomic features. The lung segmentation model gave the Sorensen-Dice coefficient of 94.86% in the validation dataset, and 93.36% in the testing dataset. In 5-fold cross-validation, the accuracy for all classes ranged from 91% to 93%, keeping slightly higher specificity than sensitivity and NPV than PPV. In the hold-out test set, the balanced accuracy ranged between 68% and 100%. The highest performance was obtained for the subtypes N1, P1, and C1. A similar performance was obtained on the independent dataset for normal and COVID-19 class subtypes. Seventy-six percent of COVID-19 patients wrongly classified as normal cases were annotated by radiologists as with no signs of disease. Finally, we developed the online service (https://circa.aei.polsl.pl) to provide access to fast diagnosis support tools.

Details

Database :
OAIster
Publication Type :
Electronic Resource
Accession number :
edsoai.on1381572992
Document Type :
Electronic Resource