Back to Search Start Over

Fecal Volatile Metabolomics Predict Gram-Negative Late-Onset Sepsis in Preterm Infants: A Nationwide Case-Control Study

Authors :
Frerichs, N.M.
El Manouni El Hassani, S.
Deianova, N.
Weissenbruch, M.M. van
Kaam, A.H. van
Vijlbrief, D.C.
Goudoever, J.B. van
Hulzebos, C.V.
Kramer, B.W.
d'Haens, E.J.
Cossey, V.
Boode, W.P. de
Jonge, W.J. de
Wicaksono, A.N.
Covington, J.A.
Benninga, M.A.
Boer, N.K. de
Niemarkt, H.J.
Meij, T.G. de
Frerichs, N.M.
El Manouni El Hassani, S.
Deianova, N.
Weissenbruch, M.M. van
Kaam, A.H. van
Vijlbrief, D.C.
Goudoever, J.B. van
Hulzebos, C.V.
Kramer, B.W.
d'Haens, E.J.
Cossey, V.
Boode, W.P. de
Jonge, W.J. de
Wicaksono, A.N.
Covington, J.A.
Benninga, M.A.
Boer, N.K. de
Niemarkt, H.J.
Meij, T.G. de
Source :
Microorganisms; 2076-2607; 3; 11; 572; ~Microorganisms~~~~~2076-2607~3~11~~572
Publication Year :
2023

Abstract

Item does not contain fulltext<br />Early detection of late-onset sepsis (LOS) in preterm infants is crucial since timely treatment initiation is a key prognostic factor. We hypothesized that fecal volatile organic compounds (VOCs), reflecting microbiota composition and function, could serve as a non-invasive biomarker for preclinical pathogen-specific LOS detection. Fecal samples and clinical data of all preterm infants (≤30 weeks' gestation) admitted at nine neonatal intensive care units in the Netherlands and Belgium were collected daily. Samples from one to three days before LOS onset were analyzed by gas chromatography-ion mobility spectrometry (GC-IMS), a technique based on pattern recognition, and gas chromatography-time of flight-mass spectrometry (GC-TOF-MS), to identify unique metabolites. Fecal VOC profiles and metabolites from infants with LOS were compared with matched controls. Samples from 121 LOS infants and 121 matched controls were analyzed using GC-IMS, and from 34 LOS infants and 34 matched controls using GC-TOF-MS. Differences in fecal VOCs were most profound one and two days preceding Escherichia coli LOS (Area Under Curve; p-value: 0.73; p = 0.02, 0.83; p < 0.002, respectively) and two and three days before gram-negative LOS (0.81; p < 0.001, 0.85; p < 0.001, respectively). GC-TOF-MS identified pathogen-specific discriminative metabolites for LOS. This study underlines the potential for VOCs as a non-invasive preclinical diagnostic LOS biomarker.

Details

Database :
OAIster
Journal :
Microorganisms; 2076-2607; 3; 11; 572; ~Microorganisms~~~~~2076-2607~3~11~~572
Publication Type :
Electronic Resource
Accession number :
edsoai.on1375457092
Document Type :
Electronic Resource