Back to Search Start Over

Technical note: evaluation of a spatial optimization model for prostate high dose‐rate brachytherapy in a clinical treatment planning system

Authors :
Morén, Björn
Bokrantz, Rasmus
Dohlmar, Frida
Andersson, Björn
Setterquist, Erik
Larsson, Torbjörn
Carlsson Tedgren, Åsa
Morén, Björn
Bokrantz, Rasmus
Dohlmar, Frida
Andersson, Björn
Setterquist, Erik
Larsson, Torbjörn
Carlsson Tedgren, Åsa
Publication Year :
2023

Abstract

BackgroundSpatial properties of a dose distribution, such as volumes of contiguous hot spots, are of clinical importance in treatment planning for high dose-rate brachytherapy (HDR BT). We have in an earlier study developed an optimization model that reduces the prevalence of contiguous hot spots by modifying a tentative treatment plan. PurposeThe aim of this study is to incorporate the correction of hot spots in a standard inverse planning workflow and to validate the integrated model in a clinical treatment planning system. The spatial function is included in the objective function for the inverse planning, as opposed to in the previous study where it was applied as a separate post-processing step. Our aim is to demonstrate that fine-adjustments of dose distributions, which are often performed manually in todays clinical practice, can be automated. MethodsA spatial optimization function was introduced in the treatment planning system RayStation (RaySearch Laboratories AB, Stockholm, Sweden) via a research interface. A series of 10 consecutive prostate patients treated with HDR BT was retrospectively replanned with and without the spatial function. ResultsOptimization with the spatial function decreased the volume of the largest contiguous hot spot by on average 31%, compared to if the function was not included. The volume receiving at least 200% of the prescription dose decreased by on average 11%. Target coverage, measured as the fractions of the clinical target volume (CTV) and the planning target volume (PTV) receiving at least the prescription dose, was virtually unchanged (less than a percent change for both metrics). Organs-at-risk received comparable or slightly decreased doses if the spatial function was included in the optimization model. ConclusionsOptimization of spatial properties such as the volume of contiguous hot spots can be integrated in a standard inverse planning workflow for brachytherapy, and need not be conducted as a separate post-processin<br />Funding: Vetenskapsradet (VR) [VR-NT 2019-155 05416]; Cancerfonden (Swedish Cancer Society) [CAN 2017/1029, Pj 211788]

Details

Database :
OAIster
Notes :
application/pdf, English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1372229981
Document Type :
Electronic Resource
Full Text :
https://doi.org/10.1002.mp.16166