Back to Search Start Over

Improved measurements of the beta-decay response of liquid xenon with the LUX detector

Authors :
Akerib, DS
Akerib, DS
Alsum, S
Araujo, HM
Bai, X
Balajthy, J
Baxter, A
Beltrame, P
Bernard, EP
Bernstein, A
Biesiadzinski, TP
Boulton, EM
Boxer, B
Bras, P
Burdin, S
Byram, D
Carmona-Benitez, MC
Chan, C
Cutter, JE
de Viveiros, L
Druszkiewicz, E
Fallon, SR
Fan, A
Fiorucci, S
Gaitskell, RJ
Genovesi, J
Ghag, C
Gilchriese, MGD
Gwilliam, C
Hall, CR
Haselschwardt, SJ
Hertel, SA
Hogan, DP
Horn, M
Huang, DQ
Ignarra, CM
Jacobsen, RG
Jahangir, O
Ji, W
Kamdin, K
Kazkaz, K
Khaitan, D
Korolkova, EV
Kravitz, S
Kudryavtsev, VA
Leason, E
Lenardo, BG
Lesko, KT
Liao, J
Lin, J
Lindote, A
Lopes, MI
Manalaysay, A
Mannino, RL
Marangou, N
Marzioni, MF
McKinsey, DN
Mei, D-M
Moongweluwan, M
Morad, JA
Murphy, A St J
Naylor, A
Nehrkorn, C
Nelson, HN
Neves, F
Nilima, A
Oliver-Mallory, KC
Palladino, KJ
Pease, EK
Riffard, Q
Rischbieter, GRC
Rhyne, C
Rossiter, P
Shaw, S
Shutt, TA
Silva, C
Solmaz, M
Solovov, VN
Sorensen, P
Sumner, TJ
Szydagis, M
Taylor, DJ
Taylor, R
Taylor, WC
Tennyson, BP
Terman, PA
Tiedt, DR
To, WH
Tripathi, M
Tvrznikova, L
Utku, U
Uvarov, S
Vacheret, A
Velan, V
Webb, RC
White, JT
Whitis, TJ
Witherell, MS
Wolfs, FLH
Woodward, D
Xu, J
Akerib, DS
Akerib, DS
Alsum, S
Araujo, HM
Bai, X
Balajthy, J
Baxter, A
Beltrame, P
Bernard, EP
Bernstein, A
Biesiadzinski, TP
Boulton, EM
Boxer, B
Bras, P
Burdin, S
Byram, D
Carmona-Benitez, MC
Chan, C
Cutter, JE
de Viveiros, L
Druszkiewicz, E
Fallon, SR
Fan, A
Fiorucci, S
Gaitskell, RJ
Genovesi, J
Ghag, C
Gilchriese, MGD
Gwilliam, C
Hall, CR
Haselschwardt, SJ
Hertel, SA
Hogan, DP
Horn, M
Huang, DQ
Ignarra, CM
Jacobsen, RG
Jahangir, O
Ji, W
Kamdin, K
Kazkaz, K
Khaitan, D
Korolkova, EV
Kravitz, S
Kudryavtsev, VA
Leason, E
Lenardo, BG
Lesko, KT
Liao, J
Lin, J
Lindote, A
Lopes, MI
Manalaysay, A
Mannino, RL
Marangou, N
Marzioni, MF
McKinsey, DN
Mei, D-M
Moongweluwan, M
Morad, JA
Murphy, A St J
Naylor, A
Nehrkorn, C
Nelson, HN
Neves, F
Nilima, A
Oliver-Mallory, KC
Palladino, KJ
Pease, EK
Riffard, Q
Rischbieter, GRC
Rhyne, C
Rossiter, P
Shaw, S
Shutt, TA
Silva, C
Solmaz, M
Solovov, VN
Sorensen, P
Sumner, TJ
Szydagis, M
Taylor, DJ
Taylor, R
Taylor, WC
Tennyson, BP
Terman, PA
Tiedt, DR
To, WH
Tripathi, M
Tvrznikova, L
Utku, U
Uvarov, S
Vacheret, A
Velan, V
Webb, RC
White, JT
Whitis, TJ
Witherell, MS
Wolfs, FLH
Woodward, D
Xu, J
Source :
PHYSICAL REVIEW D; vol 100, iss 2, 022002; 1550-7998
Publication Year :
2019

Abstract

We report results from an extensive set of measurements of the \b{eta}-decay response in liquid xenon.These measurements are derived from high-statistics calibration data from injected sources of both $^{3}$H and $^{14}$C in the LUX detector. The mean light-to-charge ratio is reported for 13 electric field values ranging from 43 to 491 V/cm, and for energies ranging from 1.5 to 145 keV.

Details

Database :
OAIster
Journal :
PHYSICAL REVIEW D; vol 100, iss 2, 022002; 1550-7998
Notes :
application/pdf, PHYSICAL REVIEW D vol 100, iss 2, 022002 1550-7998
Publication Type :
Electronic Resource
Accession number :
edsoai.on1367462220
Document Type :
Electronic Resource