Reduction of Peristalsis-Related Streak Artifacts on the Liver with Dual-Layer Spectral CT.

Authors :
Grosu, Sergio
Grosu, Sergio
Wang, Zhen J
Obmann, Markus M
Sugi, Mark D
Sun, Yuxin
Yeh, Benjamin M
Grosu, Sergio
Grosu, Sergio
Wang, Zhen J
Obmann, Markus M
Sugi, Mark D
Sun, Yuxin
Yeh, Benjamin M
Source :
Diagnostics (Basel, Switzerland); vol 12, iss 4, 782; 2075-4418
Publication Year :
2022

Abstract

BackgroundPeristalsis-related streak artifacts on the liver compromise image quality and diagnostic accuracy.PurposeTo assess dual-layer spectral-detector computed tomography (CT) image reconstructions for reducing intestinal peristalsis-related streak artifacts on the liver.MethodsWe retrospectively evaluated 220 contrast-enhanced abdominal dual-energy CT scans in 131 consecutive patients (mean age: 68 ± 10 years, 120 men) who underwent routine clinical dual-layer spectral-detector CT imaging (120 kVp, 40 keV, 200 keV, virtual non-contrast (VNC), iodine images). Two independent readers evaluated bowel peristalsis streak artifacts on the liver qualitatively on a five-point Likert scale (1 = none to 5 = severe) and quantitatively by depth of streak artifact extension into the liver and measurements of Hounsfield Unit and iodine concentration differences from normal liver. Artifact severity between image reconstructions were compared by Wilcoxon signed-rank and paired t-tests.Results12 scans were excluded due to missing spectral data, artifacts on the liver originating from metallic foreign materials, or oral contrast material. Streak artifacts on the liver were seen in 51/208 (25%) scans and involved the left lobe only in 49/51 (96%), the right lobe only in 0/51 (0%), and both lobes in 2/51 (4%) scans. Artifact frequency was lower in iodine than in 120 kVp images (scans 18/208 vs. 51/208, p < 0.001). Artifact severity was less in iodine than in 120 kVp images (median score 1 vs. 3, p < 0.001). Streak artifact extension into the liver was shorter in iodine than 120 kVp images (mean length 2 ± 4 vs. 12 ± 5 mm, p < 0.001). Hounsfield Unit and iodine concentration differed significantly between bright streak artifacts and normal liver in 120 kVp, 40 keV, 200 keV, and VNC images (p < 0.001, each), but not in iodine images (p = 0.23).ConclusionIntestinal peristalsis-related streak artifacts commonly affect the left liver lobe at CT and can be substantially redu

Details

Database :
OAIster
Journal :
Diagnostics (Basel, Switzerland); vol 12, iss 4, 782; 2075-4418
Notes :
application/pdf, Diagnostics (Basel, Switzerland) vol 12, iss 4, 782 2075-4418
Publication Type :
Electronic Resource
Accession number :
edsoai.on1367389931
Document Type :
Electronic Resource