Back to Search Start Over

Atrial function in Fontan patients assessed by CMR: Relation with exercise capacity and long-term outcomes

Authors :
Ven, J.P.G. van der
Alsaied, T.
Juggan, S.
Bossers, S.S.
Bosch, E. van den
Kapusta, L.
Kuipers, I.M.
Kroft, L.J.
Harkel, A.D. Ten
Iperen, G.G. van
Rathod, R.H.
Helbing, W.A.
Ven, J.P.G. van der
Alsaied, T.
Juggan, S.
Bossers, S.S.
Bosch, E. van den
Kapusta, L.
Kuipers, I.M.
Kroft, L.J.
Harkel, A.D. Ten
Iperen, G.G. van
Rathod, R.H.
Helbing, W.A.
Source :
International Journal of Cardiology; 56; 61; 0167-5273; 312; ~International Journal of Cardiology~56~61~~~0167-5273~~312~~
Publication Year :
2020

Abstract

Contains fulltext : 220818.pdf (Publisher’s version ) (Open Access)<br />OBJECTIVE: To assess the role of atrial function on exercise capacity and clinical events in Fontan patients. DESIGN: We included 96 Fontan patients from 6 tertiary centers, aged 12.8 (IQR 10.1-15.6) years, who underwent cardiac magnetic resonance imaging and cardiopulmonary exercise testing within 12 months of each other from 2004 to 2017. Intra-atrial lateral tunnel (ILT) and extracardiac conduit (ECC) patients were matched 1:1 with regard to age, gender and dominant ventricle. The pulmonary venous atrium was manually segmented in all phases and slices. Atrial function was assessed by volume-time curves. Furthermore, atrial longitudinal and circumferential feature tracking strain was assessed. We determined the relation between atrial function and exercise capacity, assessed by peak oxygen uptake and VE/VCO2 slope, and events (mortality, listing for transplant, re-intervention, arrhythmia) during follow-up. RESULTS: Atrial maximal and minimal volumes did not differ between ILT and ECC patients. ECC patients had higher reservoir function (21.1 [16.4-28.0]% vs 18.2 [10.9-22.2]%, p = .03), lower conduit function and lower total circumferential strain (13.8 +/- 5.1% vs 18.0 +/- 8.7%, p = .01), compared to ILT patients. Only for ECC patients, a better late peak circumferential strain rate predicted better VE/VCO2 slope. No other parameter of atrial function predicted peak oxygen uptake or VE/VCO2 slope. During a median follow-up of 6.2 years, 42 patients reached the composite end-point. No atrial function parameters predicted events during follow-up. CONCLUSIONS: ECC patients have higher atrial reservoir function and lower conduit function. Atrial function did not predict exercise capacity or events during follow-up.

Details

Database :
OAIster
Journal :
International Journal of Cardiology; 56; 61; 0167-5273; 312; ~International Journal of Cardiology~56~61~~~0167-5273~~312~~
Publication Type :
Electronic Resource
Accession number :
edsoai.on1366695025
Document Type :
Electronic Resource