Back to Search Start Over

Evaluation of substrate clogging in a full-scale horizontal subsurface flow treatment wetland using electrical resistivity tomography with an optimized electrode configuration

Authors :
Universitat Politècnica de Catalunya. Departament d'Òptica i Optometria
Universitat Politècnica de Catalunya. CITES - Grup de Recerca en Ciència i Tecnologia de la Sostenibilitat
Liu, Huaqing
Liu, Zhengyu
Morató Farreras, Jordi
Hu, Zhen
Zhuang, Linlan
Kang, Xingsheng
Pang, Yonghao
Universitat Politècnica de Catalunya. Departament d'Òptica i Optometria
Universitat Politècnica de Catalunya. CITES - Grup de Recerca en Ciència i Tecnologia de la Sostenibilitat
Liu, Huaqing
Liu, Zhengyu
Morató Farreras, Jordi
Hu, Zhen
Zhuang, Linlan
Kang, Xingsheng
Pang, Yonghao
Publication Year :
2022

Abstract

This study investigated the spatial distribution of clogging matter in a full-scale horizontal subsurface flow treatment wetland (HSSF TW) based on an electrical resistivity tomography (ERT) method, comparing the performance of two different electrode configurations (i.e., Schlumberger and Wenner arrays). The results indicated that during the draining phase, the substrate apparent resistivities of the full-scale HSSF TWs were negatively correlated with the clogging matter fraction (v/v), and a functional relationship between the two parameters was established using a first-order k-C* model. The detected clogging matter fraction (v/v) based on the Schlumberger array showed higher accuracy (linear slope = 0.900, R-squared = 0.902) than the Wenner array (linear slope = 0.685, R-squared = 0.685). Most of the severe substrate clogging in the full-scale HSSF TW occurred within a 10-m flow distance, and the distribution of the clogging matter showed different characteristics at different substrate depths. From a cross section positioned 1 m from the inlet, the average clogging matter fraction (v/v) at a 0–0.30 m depth (23.1 ± 14.9%) was significantly higher than that at a 0.30–0.80 m depth (5.0 ± 2.1%). The clogging matter at a 5-m flow distance was evenly distributed at different substrate depths. Only a few localized clogging zones were observed in the cross section at a 10-m flow distance. This study provided an accurate and feasible method for investigating the volume fraction of clogging matters containing different organic contents and demonstrates the spatial heterogeneity of clogging matter in HSSF TWs.<br />This research was funded by the Shandong Province Key Research and Development Program , China (Major Scientific and Technologica lInnovation Project) (No. 2020CXGC011406 & No . 2019JZZY010411), National Science Foundation of China (Nos . 51878388 , 52170043 & 42107230), Natural Science Foundation of Shandong Province (No. ZR2020YQ42), and Future Plan for Young Scholar of Shandong University .<br />Peer Reviewed<br />Postprint (author's final draft)

Details

Database :
OAIster
Notes :
8 p., application/pdf, English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1355847968
Document Type :
Electronic Resource