Back to Search Start Over

Transcatheter Aortic Valve Replacement With the LOTUS Edge System:Early European Experience

Authors :
Armario, Xavier
Rosseel, Liesbeth
Kharbanda, Rajesh
Khogali, Saib
Abdel-Wahab, Mohamed
Van Mieghem, Nicolas M.
Tchétché, Didier
Dumonteil, Nicolas
De Backer, Ole
Cotton, James
McGrath, Brian
Balakrishnan, Deepu
Ali, Noman
Farhan, Serdar
Joseph, Jubin
Charbonnier, Gaetan
Okuno, Taishi
McHugh, Fiachra
Hildick-Smith, David
Gilgen, Nicole
Hokken, Thijmen
Spence, Mark S.
Frerker, Christian
Angelillis, Marco
Grygier, Marek
Cockburn, James
Bjursten, Henrik
Jeger, Raban V.
Teles, Rui
Petronio, Anna S.
Pilgrim, Thomas
Sinning, Jan Malte
Nickenig, Georg
Søndergaard, Lars
Blackman, Daniel J.
Mylotte, Darren
Armario, Xavier
Rosseel, Liesbeth
Kharbanda, Rajesh
Khogali, Saib
Abdel-Wahab, Mohamed
Van Mieghem, Nicolas M.
Tchétché, Didier
Dumonteil, Nicolas
De Backer, Ole
Cotton, James
McGrath, Brian
Balakrishnan, Deepu
Ali, Noman
Farhan, Serdar
Joseph, Jubin
Charbonnier, Gaetan
Okuno, Taishi
McHugh, Fiachra
Hildick-Smith, David
Gilgen, Nicole
Hokken, Thijmen
Spence, Mark S.
Frerker, Christian
Angelillis, Marco
Grygier, Marek
Cockburn, James
Bjursten, Henrik
Jeger, Raban V.
Teles, Rui
Petronio, Anna S.
Pilgrim, Thomas
Sinning, Jan Malte
Nickenig, Georg
Søndergaard, Lars
Blackman, Daniel J.
Mylotte, Darren
Source :
Armario , X , Rosseel , L , Kharbanda , R , Khogali , S , Abdel-Wahab , M , Van Mieghem , N M , Tchétché , D , Dumonteil , N , De Backer , O , Cotton , J , McGrath , B , Balakrishnan , D , Ali , N , Farhan , S , Joseph , J , Charbonnier , G , Okuno , T , McHugh , F , Hildick-Smith , D , Gilgen , N , Hokken , T , Spence , M S , Frerker , C , Angelillis , M , Grygier , M , Cockburn , J , Bjursten , H , Jeger , R V , Teles , R , Petronio , A S , Pilgrim , T , Sinning , J M , Nickenig , G , Søndergaard , L , Blackman , D J & Mylotte , D 2021 , ' Transcatheter Aortic Valve Replacement With the LOTUS Edge System : Early European Experience ' , JACC: Cardiovascular Interventions , vol. 14 , no. 2 , pp. 172-181 .
Publication Year :
2021

Abstract

Objectives: The aim of this study was to evaluate the short-term safety and efficacy of transcatheter aortic valve replacement (TAVR) with the LOTUS Edge system. Background: The LOTUS Edge system was commercially re-released in April 2019. The authors report the first European experience with this device. Methods: A multicenter, single-arm, retrospective registry was initiated to evaluate short-term clinical outcomes. Included cases are the first experience with this device and new implantation technique in Europe. Clinical, echocardiographic, and computed tomographic data were analyzed. Endpoints were defined according to Valve Academic Research Consortium-2 and were site reported. Results: Between April and November 2019, 286 consecutive patients undergoing TAVR with the LOTUS Edge system at 18 European centers were included. The mean age and Society of Thoracic Surgeons score were 81.2 ± 6.9 years and 5.2 ± 5.4%, respectively. Nearly one-half of all patients (47.9%) were considered to have complex anatomy. Thirty-day major adverse events included death (2.4% [n = 7]) and stroke (3.5% [n = 10]). After TAVR, the mean aortic valve area was 1.9 ± 0.9 cm2, and the mean transvalvular gradient was 11.9 ± 5.7 mm Hg. None or trace paravalvular leak (PVL) occurred in 84.4% and moderate PVL in 2.0%. There were no cases of severe PVL. New permanent pacemaker (PPM) implantation was required in 25.9% among all patients and 30.8% among PPM-naive patients. Conclusions: Early experience with the LOTUS Edge system demonstrated satisfactory short-term safety and efficacy, favorable hemodynamic data, and very low rates of PVL in an anatomically complex cohort. New PPM implantation remained high. Further study will evaluate if increasing operator experience with the device and new implantation technique can reduce the incidence of PPM implantation.

Details

Database :
OAIster
Journal :
Armario , X , Rosseel , L , Kharbanda , R , Khogali , S , Abdel-Wahab , M , Van Mieghem , N M , Tchétché , D , Dumonteil , N , De Backer , O , Cotton , J , McGrath , B , Balakrishnan , D , Ali , N , Farhan , S , Joseph , J , Charbonnier , G , Okuno , T , McHugh , F , Hildick-Smith , D , Gilgen , N , Hokken , T , Spence , M S , Frerker , C , Angelillis , M , Grygier , M , Cockburn , J , Bjursten , H , Jeger , R V , Teles , R , Petronio , A S , Pilgrim , T , Sinning , J M , Nickenig , G , Søndergaard , L , Blackman , D J & Mylotte , D 2021 , ' Transcatheter Aortic Valve Replacement With the LOTUS Edge System : Early European Experience ' , JACC: Cardiovascular Interventions , vol. 14 , no. 2 , pp. 172-181 .
Notes :
English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1322775270
Document Type :
Electronic Resource