Back to Search Start Over

Evaluating Efficacy of Antimicrobial and Antifouling Materials for Urinary Tract Medical Devices:Challenges and Recommendations

Authors :
Ramstedt, Madeleine
Ribeiro, Isabel A. C.
Bujdakova, Helena
Mergulhão, Filipe J. M.
Jordao, Luisa
Thomsen, Peter
Alm, Martin
Burmølle, Mette
Vladkova, Todorka
Can, Fusun
Reches, Meital
Riool, Martijn
Barros, Alexandre
Reis, Rui L
Meaurio, Emilio
Kikhney, Judith
Moter, Annette
Zaat, Sebastian A J
Sjollema, Jelmer
Ramstedt, Madeleine
Ribeiro, Isabel A. C.
Bujdakova, Helena
Mergulhão, Filipe J. M.
Jordao, Luisa
Thomsen, Peter
Alm, Martin
Burmølle, Mette
Vladkova, Todorka
Can, Fusun
Reches, Meital
Riool, Martijn
Barros, Alexandre
Reis, Rui L
Meaurio, Emilio
Kikhney, Judith
Moter, Annette
Zaat, Sebastian A J
Sjollema, Jelmer
Source :
Ramstedt , M , Ribeiro , I A C , Bujdakova , H , Mergulhão , F J M , Jordao , L , Thomsen , P , Alm , M , Burmølle , M , Vladkova , T , Can , F , Reches , M , Riool , M , Barros , A , Reis , R L , Meaurio , E , Kikhney , J , Moter , A , Zaat , S A J & Sjollema , J 2019 , ' Evaluating Efficacy of Antimicrobial and Antifouling Materials for Urinary Tract Medical Devices : Challenges and Recommendations ' , Macromolecular Bioscience , vol. 19 , no. 5 , 1800384 .
Publication Year :
2019

Abstract

In Europe, the mean incidence of urinary tract infections in intensive care units is 1.1 per 1000 patient-days. Of these cases, catheter-associated urinary tract infections (CAUTI) account for 98%. In total, CAUTI in hospitals is estimated to give additional health-care costs of £1-2.5 billion in the United Kingdom alone. This is in sharp contrast to the low cost of urinary catheters and emphasizes the need for innovative products that reduce the incidence rate of CAUTI. Ureteral stents and other urinary-tract devices suffer similar problems. Antimicrobial strategies are being developed, however, the evaluation of their efficacy is very challenging. This review aims to provide considerations and recommendations covering all relevant aspects of antimicrobial material testing, including surface characterization, biocompatibility, cytotoxicity, in vitro and in vivo tests, microbial strain selection, and hydrodynamic conditions, all in the perspective of complying to the complex pathology of device-associated urinary tract infection. The recommendations should be on the basis of standard assays to be developed which would enable comparisons of results obtained in different research labs both in industry and in academia, as well as provide industry and academia with tools to assess the antimicrobial properties for urinary tract devices in a reliable way.

Details

Database :
OAIster
Journal :
Ramstedt , M , Ribeiro , I A C , Bujdakova , H , Mergulhão , F J M , Jordao , L , Thomsen , P , Alm , M , Burmølle , M , Vladkova , T , Can , F , Reches , M , Riool , M , Barros , A , Reis , R L , Meaurio , E , Kikhney , J , Moter , A , Zaat , S A J & Sjollema , J 2019 , ' Evaluating Efficacy of Antimicrobial and Antifouling Materials for Urinary Tract Medical Devices : Challenges and Recommendations ' , Macromolecular Bioscience , vol. 19 , no. 5 , 1800384 .
Notes :
application/pdf, English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1322723935
Document Type :
Electronic Resource