Back to Search Start Over

Complementing Prostate SBRT VMAT With a Two-Beam Non-Coplanar IMRT Class Solution to Enhance Rectum and Bladder Sparing With Minimum Increase in Treatment Time

Authors :
Sharfo, Abdul Wahab M.
Rossi, Linda
Dirkx, Maarten L.P.
Breedveld, Sebastiaan
Aluwini, Shafak
Heijmen, Ben J.M.
Sharfo, Abdul Wahab M.
Rossi, Linda
Dirkx, Maarten L.P.
Breedveld, Sebastiaan
Aluwini, Shafak
Heijmen, Ben J.M.
Source :
Sharfo , A W M , Rossi , L , Dirkx , M L P , Breedveld , S , Aluwini , S & Heijmen , B J M 2021 , ' Complementing Prostate SBRT VMAT With a Two-Beam Non-Coplanar IMRT Class Solution to Enhance Rectum and Bladder Sparing With Minimum Increase in Treatment Time ' , Frontiers in Oncology , vol. 11 , 620978 .
Publication Year :
2021

Abstract

Purpose: Enhance rectum and bladder sparing in prostate SBRT with minimum increase in treatment time by complementing dual-arc coplanar VMAT with a two-beam non-coplanar IMRT class solution (CS). Methods: For twenty patients, an optimizer for automated multi-criterial planning with integrated beam angle optimization (BAO) was used to generate dual-arc VMAT plans, supplemented with five non-coplanar IMRT beams with individually optimized orientations (VMAT+5). In all plan generations, reduction of high rectum dose had the highest priority after obtaining adequate PTV coverage. A CS with two most preferred directions in VMAT+5 and largest rectum dose reductions compared to dual-arc VMAT was then selected to define VMAT+CS. VMAT+CS was compared with automatically generated i) dual-arc coplanar VMAT plans (VMAT), ii) VMAT+5 plans, and iii) IMRT plans with 30 patient-specific non-coplanar beam orientations (30-NCP). Plans were generated for a 4 x 9.5 Gy fractionation scheme. Differences in PTV doses, healthy tissue sparing, and computation and treatment delivery times were quantified. Results: For equal PTV coverage, VMAT+CS, consisting of dual-arc VMAT supplemented with two fixed, non-coplanar IMRT beams with fixed Gantry/Couch angles of 65°/30° and 295°/-30°, significantly reduced OAR doses and the dose bath, compared to dual-arc VMAT. Mean relative differences in rectum Dmean, D1cc, V40GyEq and V60GyEq were 19.4 ± 10.6%, 4.2 ± 2.7%, 34.9 ± 20.3%, and 39.7 ± 23.2%, respectively (all p<0.001). There was no difference in bladder D1cc, while bladder Dmean reduced by 17.9 ± 11.0% (p<0.001). Also, the clinically evaluated urethra D5%, D10%, and D50% showed small, but statistically significant improvements. All patient VX with X = 2, 5, 10, 20, and 30 Gy were reduced with VMAT+CS, with a maximum relative reduction for V10Gy of 19.0 ± 7.3% (p<0.

Details

Database :
OAIster
Journal :
Sharfo , A W M , Rossi , L , Dirkx , M L P , Breedveld , S , Aluwini , S & Heijmen , B J M 2021 , ' Complementing Prostate SBRT VMAT With a Two-Beam Non-Coplanar IMRT Class Solution to Enhance Rectum and Bladder Sparing With Minimum Increase in Treatment Time ' , Frontiers in Oncology , vol. 11 , 620978 .
Notes :
application/pdf, English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1322185248
Document Type :
Electronic Resource