Back to Search
Start Over
Feasibility of late gadolinium enhancement (LGE) in ischemic cardiomyopathy using 2D-multisegment LGE combined with artificial intelligence reconstruction deep learning noise reduction algorithm
- Publication Year :
- 2021
-
Abstract
- Background: Despite the low spatial resolution of 2D-multisegment late gadolinium enhancement (2D-MSLGE) sequences, it may be useful in uncooperative patients instead of standard 2D single segmented inversion recovery gradient echo late gadolinium enhancement sequences (2D-SSLGE). The aim of the study is to assess the feasibility and comparison of 2D-MSLGE reconstructed with artificial intelligence reconstruction deep learning noise reduction (NR) algorithm compared to standard 2D-SSLGE in consecutive patients with ischemic cardiomyopathy (ICM). Methods: Fifty-seven patients with known ICM referred for a clinically indicated CMR were enrolled in this study. 2D-MSLGE were reconstructed using a growing level of NR (0%,25%,50%,75%and 100%). Subjective image quality, signal to noise ratio (SNR) and contrast to noise ratio (CNR) were evaluated in each dataset and compared to standard 2D-SSLGE. Moreover, diagnostic accuracy, LGE mass and scan time were compared between 2D-MSLGE with NR and 2D-SSLGE. Results: The application of NR reconstruction ≥50% to 2D-MSLGE provided better subjective image quality, CNR and SNR compared to 2D-SSLGE (p < 0.01). The best compromise in terms of subjective and objective image quality was observed for values of 2D-MSLGE 75%, while no differences were found in terms of LGE quantification between 2D-MSLGE versus 2D-SSLGE, regardless the NR applied. The sensitivity, specificity, negative predictive value, positive predictive value and accuracy of 2D-MSLGE NR 75% were 87.77%,96.27%,96.13%,88.16% and 94.22%, respectively. Time of acquisition of 2D-MSLGE was significantly shorter compared to 2D-SSLGE (p < 0.01). Conclusion: When compared to standard 2D-SSLGE, the application of NR reconstruction to 2D-MSLGE provides superior image quality with similar diagnostic accuracy.
Details
- Database :
- OAIster
- Notes :
- STAMPA, English
- Publication Type :
- Electronic Resource
- Accession number :
- edsoai.on1322052851
- Document Type :
- Electronic Resource