Back to Search Start Over

Functional capacity, physical activity and muscle strength assessment of individuals with non-small cell lung cancer: a systematic review of instruments and their measurement properties

Authors :
Granger, CL
McDonald, CF
Parry, SM
Oliveira, CC
Denehy, L
Granger, CL
McDonald, CF
Parry, SM
Oliveira, CC
Denehy, L
Publication Year :
2013

Abstract

BACKGROUND: The measurement properties of instruments used to assess functional capacity, physical activity and muscle strength in participants with non-small cell lung cancer (NSCLC) have not been systematically reviewed. OBJECTIVES: To identify outcome measures used to assess these outcomes in participants with NSCLC; and to evaluate, synthesise and compare the measurement properties of the outcome measures identified. DATA SOURCES: A systematic review of articles using electronic databases MEDLINE (1950-2012), CINAHL (1982-2012), EMBASE (1980-2012), Cochrane Library (2012), Expanded Academic ASAP (1994-2012), Health Collection Informit (1995-2012) and PEDRO (1999-2012). Additional studies were identified by searching personal files and cross referencing. Eligibility Criteria for Study Selection: Search one: studies which assessed functional capacity, physical activity or muscle strength in participants with NSCLC using non-laboratory objective tests were included. Search two: studies which evaluated a measurement property (inter- or intra-rater reliability; measurement error; criterion or construct validity; or responsiveness) in NSCLC for one of the outcome measures identified in search one. Studies published in English from 1980 were eligible. Data Extraction and Methodological Quality Assessment: data collection form was developed and data extracted. Methodological quality of studies was assessed by two independent reviewers using the 4-point COSMIN checklist. RESULTS: Thirteen outcome measures were identified. Thirty-one studies evaluating measurement properties of the outcome measures in participants with NSCLC were included. Functional capacity was assessed using the six- and twelve-minute walk tests; incremental- and endurance-shuttle walk tests; and the stair-climbing test. Criterion validity for three of these measures was established in NSCLC but not the reliability or responsiveness. Physical activity was measured using accelerometers and pedometers. O

Details

Database :
OAIster
Publication Type :
Electronic Resource
Accession number :
edsoai.on1315680421
Document Type :
Electronic Resource