Back to Search
Start Over
Adaptive local thresholding can enhance the accuracy of HR-pQCT-based trabecular bone morphology assessment
- Source :
- Bone vol.154 (2022) date: 2022-01-01 [ISSN 8756-3282]
- Publication Year :
- 2022
-
Abstract
- High-resolution peripheral quantitative computed tomography (HR-pQCT) devices can scan extremities at bone microstructural level in vivo and are used mainly in research of bone diseases. Two HR-pQCT scanners are commercially available to date: XtremeCT (first generation) and XtremeCT-II (second generation) from Scanco Medical AG (Switzerland). Recently, we have proposed an adaptive local thresholding (AT) technique and showed that it can improve quantification accuracy of bone microstructural parameters, with visually less sharp cone-beam CT (CBCT) images providing a similar accuracy than XtremeCT. The aim of this study was to evaluate whether the AT segmentation technique could enhance the accuracy of HR-pQCT in quantifying bone microstructural images and to assess whether the agreement between XtremeCT and XtremeCT-II could be improved.Nineteen radii were scanned with three scanners from Scanco Medical AG: (1) XtremeCT at 82 mu m, (2) XtremeCT-II at 60.7 mu m and (3) the small animal microCT scanner VivaCT40 at 19 mu m voxel size. The scans were segmented applying two different methods, once following the manufacturer standard technique (ST), and once by means of AT. Three-dimensional (3D) morphological analysis was performed on the trabecular volume of the segmented images using the manufacturer's standard software to calculate bone volume fraction (BV/TV), trabecular thickness (Tb.Th), separation (Tb.Sp) and number (Tb.N).The average accuracy of XtremeCT improved from R-2 = 0.76 (ST) to 0.85 (AT) and reached the same level of accuracy as XtremeCT-II with ST (R-2 = 0.86). The largest improvements were obtained for BV/TV and Tb.Th. For XtremeCT-II, mean accuracy improved slightly from R-2 = 0.86 (ST) to 0.89 (AT). For both segmentations and both scanners, the standard section was quantified slightly more accurate than the subchondral section. The agreement between the scanners was enhanced from R-2 = 0.89 (ST) to 0.98 (AT).In conclusion, AT can enhance the accurac
Details
- Database :
- OAIster
- Journal :
- Bone vol.154 (2022) date: 2022-01-01 [ISSN 8756-3282]
- Notes :
- DOI: 10.1016/j.bone.2021.116225, English
- Publication Type :
- Electronic Resource
- Accession number :
- edsoai.on1311954113
- Document Type :
- Electronic Resource