Back to Search
Start Over
Precise Vector-2D Magnetic Field Sensor System for Electronic Compass
- Publication Year :
- 2004
-
Abstract
- An high sensitivity vector-2D magnetic sensor system for low magnetic field measurements has been realized and tested. The system, realized in PCB technology, consists of a double axis Fluxgate magnetic sensor with its front-end electronic circuitry based on second-harmonic detection. The amorphous magnetic materials Vitrovac 6025X (25 mu m thick) and Vitrovac 6025Z (20 mu m thick) were used as a ferromagnetic core for the sensor. Applying a sinusoidal excitation current of 450 mA peak at 10 kHz with the Vitrovac 6025Z, the magnetic sensitivity was about 1.25 mV/mu T, suitable for detecting the Earth's magnetic field (+/- 60 mu T), while the linearity error is 1.5% full scale. Using the thicker Vitrovac 6025X, a maximum sensitivity of about 1.68 mV/mu T and a linearity error of about 1.55% full scale in the range of +/- 60 mu T were obtained with a larger sinusoidal excitation current of 600 mA peak at 10 kHz. The 2D vector sensor system presented is characterized by a very simple process fabrication due to the use of commercially available very thin ferromagnetic material.
Details
- Database :
- OAIster
- Notes :
- English
- Publication Type :
- Electronic Resource
- Accession number :
- edsoai.on1311385784
- Document Type :
- Electronic Resource