Back to Search Start Over

Estimates of mass absorption cross sections of black carbon for filter-based absorption photometers in the Arctic

Authors :
Ohata, Sho
Mori, Tatsuhiro
Kondo, Yutaka
Sharma, Sangeeta
Hyvärinen, Antti
Andrews, Elisabeth
Tunved, Peter
Asmi, Eija
Backman, John
Servomaa, Henri
Veber, Daniel
Koike, Makoto
Kanaya, Yugo
Yoshida, Atsushi
Moteki, Nobuhiro
Zhao, Yongjing
Matsushita, Junji
Oshima, Naga
Eleftheriadis, Konstantinos
Vratolis, Stergios
Krejci, Radovan
Zieger, Paul
Tobo, Yutaka
Ohata, Sho
Mori, Tatsuhiro
Kondo, Yutaka
Sharma, Sangeeta
Hyvärinen, Antti
Andrews, Elisabeth
Tunved, Peter
Asmi, Eija
Backman, John
Servomaa, Henri
Veber, Daniel
Koike, Makoto
Kanaya, Yugo
Yoshida, Atsushi
Moteki, Nobuhiro
Zhao, Yongjing
Matsushita, Junji
Oshima, Naga
Eleftheriadis, Konstantinos
Vratolis, Stergios
Krejci, Radovan
Zieger, Paul
Tobo, Yutaka
Publication Year :
2021

Abstract

Long-term measurements of atmospheric mass concentrations of black carbon (BC) are needed to investigate changes in its emission, transport, and deposition. However, depending on instrumentation, parameters related to BC such as aerosol absorption coefficient (babs) have been measured instead. Most ground-based measurements of babs in the Arctic have been made by filter-based absorption photometers, including particle soot absorption photometers (PSAPs), continuous light absorption photometers (CLAPs), Aethalometers, and multi-angle absorption photometers (MAAPs). The measured babs can be converted to mass concentrations of BC (MBC) by assuming the value of the mass absorption cross section (MAC; MBC= babs/ MAC). However, the accuracy of conversion of babs to MBC has not been adequately assessed. Here, we introduce a systematic method for deriving MAC values from babs measured by these instruments and independently measured MBC. In this method, MBC was measured with a filter-based absorption photometer with a heated inlet (COSMOS). COSMOS-derived MBC (MBC (COSMOS)) is traceable to a rigorously calibrated single particle soot photometer (SP2), and the absolute accuracy of MBC (COSMOS) has been demonstrated previously to be about 15 % in Asia and the Arctic. The necessary conditions for application of this method are a high correlation of the measured babs with independently measured MBC and long-term stability of the regression slope, which is denoted as MACcor (MAC derived from the correlation). In general, babs–MBC (COSMOS) correlations were high (r2= 0.76–0.95 for hourly data) at Alert in Canada, Ny-Ålesund in Svalbard, Barrow (NOAA Barrow Observatory) in Alaska, Pallastunturi in Finland, and Fukue in Japan and stable for up to 10 years. We successfully estimated MACcor values (10.8–15.1 m2 g−1 at a wavelength of 550 nm for hourly data) for these instruments, and these MACcor values can be used to obtain error-constrained estimates of MBC from babs measured at the

Details

Database :
OAIster
Notes :
English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1306186027
Document Type :
Electronic Resource
Full Text :
https://doi.org/10.5194.amt-14-6723-2021