Back to Search Start Over

High-performance thin-layer chromatography-densitometry-tandem ESI-MS to evaluate phospholipid content in exosomes of cancer cells

Authors :
Gobierno de Aragón
European Commission
Consejo Superior de Investigaciones Científicas (España)
Instituto de Salud Carlos III
European Research Council
Jarne, Carmen [0000-0002-9047-7069]
Savirón, María [0000-0001-7299-0187]
Martín Duque, Pilar [0000-0003-2890-7846]
Membrado, Luis [0000-0001-6435-7525]
Cebolla, Vicente L. [0000-0002-9786-9217]
Sancho‐Albero, María
Jarne, Carmen
Savirón, María
Martín-Duque, Pilar
Membrado, Luis
Cebolla, Vicente L.
Ricote, J.
Gobierno de Aragón
European Commission
Consejo Superior de Investigaciones Científicas (España)
Instituto de Salud Carlos III
European Research Council
Jarne, Carmen [0000-0002-9047-7069]
Savirón, María [0000-0001-7299-0187]
Martín Duque, Pilar [0000-0003-2890-7846]
Membrado, Luis [0000-0001-6435-7525]
Cebolla, Vicente L. [0000-0002-9786-9217]
Sancho‐Albero, María
Jarne, Carmen
Savirón, María
Martín-Duque, Pilar
Membrado, Luis
Cebolla, Vicente L.
Ricote, J.
Publication Year :
2022

Abstract

The question of whether exosome lipids can be considered as potential cancer biomarkers faces our current limited knowledge of their composition. This is due to the difficulty in isolating pure exosomes, the variability of the biological sources from which they are extracted, and the uncertainty of the methods for lipid characterization. Here, we present a procedure to isolate exosomes and obtain a deep, repeatable, and rapid phospholipid (PL) composition of their lipid extracts, from embryonic murine fibroblasts (NIH-3T3 cell line) and none (B16-F1) and high (B16-F10) metastatic murine skin melanoma cells. The analytical method is based on High Performance Thin-Layer Chromatography with Ultraviolet and fluorescence densitometry and coupled to Electrospray (ESI)-tandem Mass Spectrometry (MS). Under the conditions described in this work, separation and determination of PL classes, (sphingomyelins, SM; phosphatidylcholines, PC; phosphatidylserines, PS; and phosphatidylethanolamines, PE) were achieved, expressed as µg PL/100 µg exosome protein, obtained by bicinchoninic acid assay (BCA). A detailed structural characterization of molecular species of each PL class was performed by simultaneous positive and negative ESI-MS and MS/MS directly from the chromatographic plate, thanks to an elution-based interface.

Details

Database :
OAIster
Notes :
English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1293838626
Document Type :
Electronic Resource