Back to Search Start Over

Pilot study using virtual 4-D tracking electromagnetic navigation bronchoscopy in the diagnosis of pulmonary nodules : a single center prospective study

Authors :
Ishiwata, Tsukasa
Ujiie, Hideki
Gregor, Alexander
Inage, Terunaga
Motooka, Yamato
Kinoshita, Tomonari
Aragaki, Masato
Chen, Zhenchian
Effat, Andrew
Bernards, Nicholas
Yasufuku, Kazuhiro
Ishiwata, Tsukasa
Ujiie, Hideki
Gregor, Alexander
Inage, Terunaga
Motooka, Yamato
Kinoshita, Tomonari
Aragaki, Masato
Chen, Zhenchian
Effat, Andrew
Bernards, Nicholas
Yasufuku, Kazuhiro
Publication Year :
2021

Abstract

Background: Electromagnetic navigation bronchoscopy (ENB) is a navigation technology intended to improve the diagnostic yield of pulmonary nodules. However, nodule displacement due to respiratory motion may compromise the accuracy of the navigation guidance. The Veran SPiNDrive ENB system employs respiratory-gating (4D-tracking) to compensate for this motion. The aim of the present study was to evaluate the diagnostic performance and safety of the Veran SPiNDrive system for biopsy of pulmonary nodules. Methods: Adult patients with pulmonary nodules of ≥1 cm were enrolled at a single center. Both conventional bronchoscopy and 4D-tracking ENB were performed in one procedure session under general anesthesia, with the procedure order being randomly assigned. Radial probe endobronchial ultrasound and fluoroscopy were used in both groups. The diagnostic performance, safety, total procedure time, and total fluoroscopy time of the ENB phase were compared to the corresponding conventional bronchoscopy phase. Results: The study was terminated due to poor accrual; a total of eleven patients were enrolled. The mean size of pulmonary nodules was 2.1 cm. The sensitivity for malignancy was 67% (6/9) and 56% (5/9) with conventional bronchoscopy and with 4D-tracking ENB, respectively. Two cases developed minor bleeding after conventional bronchoscopy, while no complications were observed after 4D-tracking ENB. The mean procedure time was 16.1 and 21.7 min (P=0.090), and the mean duration time for fluoroscopy use was 77 and 44 sec (P=0.056) for the conventional bronchoscopy and the 4D-tracking ENB phases, respectively. Conclusions: The diagnostic performance of the Veran SPiNDrive 4D-tracking ENB did not exceed that of conventional bronchoscopy for pulmonary nodules. No complications were seen during 4D-tracking ENB. A study with a larger number of participants is required for further assessment.

Details

Database :
OAIster
Notes :
English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1291653625
Document Type :
Electronic Resource