Back to Search Start Over

Use of 6-[18F]-fluorodopamine positron emission tomography (PET) as first-line investigation for the diagnosis and localization of non-metastatic and metastatic phaeochromocytoma (PHEO).

Authors :
Timmers, H.J.L.M.
Eisenhofer, G.
Carrasquillo, J.A.
Chen, C.C.
Whatley, M.
Ling, A.
Adams, K.T.
Pacak, K.
Timmers, H.J.L.M.
Eisenhofer, G.
Carrasquillo, J.A.
Chen, C.C.
Whatley, M.
Ling, A.
Adams, K.T.
Pacak, K.
Source :
Clinical Endocrinology; 11; 17; 0300-0664; 1; 71; ~Clinical Endocrinology~11~17~~~0300-0664~1~71~~
Publication Year :
2009

Abstract

Contains fulltext : 81023timmers.pdf (publisher's version ) (Closed access)<br />OBJECTIVE: Imaging modalities available for the localization of phaeochromocytoma (PHEO) include computed tomography (CT), magnetic resonance imaging (MRI), [(123)I]- or [(131)I]-labelled metaiodobenzylguanidine ((123/131)I-MIBG) scintigraphy and 6-[(18)F]-fluorodopamine ((18)F-FDA) positron emission tomography (PET). Our aim was to investigate the yield of (18)F-FDA PET vs. biochemical testing and other imaging techniques to establish the diagnosis and location of PHEO. PATIENTS AND MEASUREMENTS: The study included 99 consecutive patients (35 Males, 64 Females, mean +/- SD age 46.4 +/- 13.4 years), who underwent (18)F-FDA PET, biochemical testing (plasma catecholamines and free metanephrines) and CT and/or MRI. The majority (78%) also underwent (123/131)I-MIBG. RESULTS: In total 26 patients had non-metastatic PHEO, 34 patients had metastatic PHEO, and PHEO was ruled out in 39 patients. Investigations to rule out or confirm PHEO yielded the following sensitivity/specificity: plasma metanephrines 97/95%, (18)F-FDA 92/90%, (123)I-MIBG 83/100%, (123/131)I-MIBG 70/100%, CT 100/41%, MRI 98/60%. Sensitivities for localizing non-metastatic PHEO on a per-lesion base were: CT 97%, MRI 92%, (18)F-FDA 78%, (123)I-MIBG 78% and (123/131)I-MIBG 76%. Sensitivities for detecting metastases on a per-patient base were: CT and MRI 100%, (18)F-FDA 97%, (123)I-MIBG 85% and (123/131)I-MIBG 65%. CONCLUSION: For tumour localization, (18)F-FDA PET and (123/131)I-MIBG scintigraphy perform equally well in patients with non-metastatic PHEO, but metastases are better detected by (18)F-FDA PET than by (123/131)I-MIBG.

Details

Database :
OAIster
Journal :
Clinical Endocrinology; 11; 17; 0300-0664; 1; 71; ~Clinical Endocrinology~11~17~~~0300-0664~1~71~~
Publication Type :
Electronic Resource
Accession number :
edsoai.on1284065754
Document Type :
Electronic Resource